Single Phase Active Electronic Reactive Fcatory Electricity Meter
$90.00
Model
SRMA-230/5(60)-3
SRMA-230/5(100)-3
SRMA-230/5(80)-3
SRMA-230/5(50)-3
SRMA-230/5(40)-3
SRMA-230/5(30)-3
SRMA-230/5(30)-2
SRMA-230/5(40)-2
SRMA-230/5(50)-2
SRMA-230/5(80)-2
SRMA-230/5(100)-2
SRMA-230/5(60)-2
SRMA-230/5(60)-1
SRMA-230/5(100)-1
SRMA-230/5(80)-1
SRMA-230/5(50)-1
SRMA-230/5(45)-1
SRMA-230/5(40)-1
SRMA-230/5(32)-1
SRMA-230/5(30)-1
Basic info
Brand Wone
Model NO. Single Phase Active Electronic Reactive Fcatory Electricity Meter
Rated voltage 230V
Rated normal current 5(60)A
Rated frequency 50(Hz)
Methods of Communication ZIGBEE
Series D123031
Product Detail

Description

The meter cover and terminal cover are made of transparent PC materials, and the internal structure of the meter and the welding assembly process are all exposed to the user,which has higher requirements on the ability of the meter manufacturer. The meter case is designed with a programming key, which has a lead block. And the removal of the lead seal can press the programming button, which can set the parameters of the meter.

Features

  • Active and reactive energy measurement

  • Mounted mounting installation

  •  Can up to 60A. RS485.

  • IR and ZIGBEE communication.

  • Multi-tariff function.

  • Meter has 3.6V Lithium battery, which is used to support multi-tariff function. And the precision of RTC is better than 0.5s/day.

  • LCD backlight allows the meter to be read in low light conditions.

  • With relay internal,which is used to remote control the meter connect and disconnect.

  • Terminal cover open detection.

  • With events records.

  • Over or Low voltage protection.

  • Electricity larceny prevention.

  •  Reactive energy can be measured.

  •  Degree of Protection: IP51 (indoor meter).

Specifications

Main
Range D123031
Product or Componet Type Energy meter
Country of origin China
Complementary
Phase Single Phase
Type of measurement

----

Metering type

Measurement

Device Application

Energy Charge

Accuracy class Active power 1.0 
Rated Current 5(60)A

Rated Voltage

230V

Network Frequency 50Hz
Technology Type Electronic
Display Type LCD display(LCD 6+2 = 999999.99kWh)
Impulse Constant

3200imp/kWh(LED)   

Maximum value measured 99999.99kWh
Tariff input Multi-tariff
Communication port protocol ---
Communication port support RS485/IR /ZIGBEE
Local signalling

------

Number of inputs -------
Number of Outputs --------------
Output voltage 230V
Mounting Mode ---
Mounting Support -----
Connections - terminals

-------

Standards

IEC62052-11/IEC62053-21



Environment
IP degree of protection

IP51

Relative humidity ≤75%
Ambient air temperature for operation -20…65 °C
Ambient Air Temperature for Storage --20…65 °C
Operating altitude ---
Dimensions 120*173.5*55mm
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 57mm
Package 1 Width 175mm
Package 1 Length 122mm
Package 1 Weight 1.000kg



Connection Diagram


image.png


Dimensions


image.png









Know your supplier
Wone
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
Analysis of Partial Discharge Principle (1)
Analysis of Partial Discharge Principle (1)
Analysis of Partial Discharge Principle (1)Under the action of an electric field, in an insulation system, discharge occurs only in some regions and does not penetrate between the conductors with the applied voltage. This phenomenon is called partial discharge. If partial discharge occurs near a conductor surrounded by gas, it can also be called corona.Partial discharge can occur not only at the edge of a conductor but also on the surface or inside an insulator. The discharge occurring on the su
Leon
07/19/2025
What types of FACTS controllers are there?
What types of FACTS controllers are there?
According to the type of connection FACTS Controller with the power system, it is classified as;Series Connected ControllerShunt Connected ControllerCombined Series-Series ControllerCombined Shunt-Series ControllerSeries-Connected ControllersSeries controllers introduce a voltage in series with the line voltage, typically using capacitive or inductive impedance devices. Their primary function is to supply or absorb variable reactive power as needed.When a transmission line is heavily loaded, the
Edwiin
07/19/2025
What are FACTS and related technologies?
What are FACTS and related technologies?
FACTS (Flexible Alternating Current Transmission System) refers to a power electronics-based system that uses static devices to enhance the power transfer capability and controllability of AC transmission networks.These power electronic devices are integrated into conventional AC grids to boost key performance metrics, including:Power transfer capacity of transmission linesVoltage stability and transient stabilityVoltage regulation precisionSystem reliabilityThermal limits of transmission infras
Edwiin
07/19/2025
What are the differences between HVAC and HVDC?
What are the differences between HVAC and HVDC?
Difference Between HVAC and HVDCElectricity generated in power plants is transmitted over long distances to electrical substations, which then distribute it to consumers. The voltage used for long-distance power transmission is extremely high, and we will explore the reasons for this high voltage later. Additionally, the transmitted power can be in either alternating current (AC) or direct current (DC) form. Therefore, power can be transmitted using either HVAC (High Voltage Alternating Current)
Edwiin
07/19/2025
What are the Advantages of HVDC over HVAC?
What are the Advantages of HVDC over HVAC?
What are the Advantages of HVDC over HVAC?Electricity travels long distances before reaching consumers. Power plants, often remote, supply electricity through hundreds of miles and multiple substations. High-voltage transmission reduces line losses, with both AC and DC used. Though AC is familiar via utility poles and home outlets, HVDC offers unique advantages in power transmission.The goal of power transmission is to minimize losses and costs. While both face influencing factors, HVDC has more
Edwiin
07/19/2025
Is the neutral - point grounding method of the power grid of 110kV and above only the neutral - point direct grounding method?
Is the neutral - point grounding method of the power grid of 110kV and above only the neutral - point direct grounding method?
Neutral - Point Grounding Modes and Protection of Transformers in Power GridsFor systems ranging from 110 kV to 500 kV, an effective grounding method shall be adopted. Specifically, under all operating conditions, the ratio of zero - sequence reactance to positive - sequence reactance X0/X1 of the system should be a positive value and not exceed 3. Meanwhile, the ratio of zero - sequence resistance to positive - sequence reactance R0/X1should also be a positive value and not exceed 1.In 330 kV a
Leon
07/19/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!