• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


EMULA Series EMU Lightning Arrester

  • EMULA Series EMU Lightning Arrester

Key attributes

Brand ROCKWILL
Model NO. EMULA Series EMU Lightning Arrester
Rated voltage 27.5kV
Series EMULA Series

Product descriptions from the supplier

Description

Overview

The high-speed railway uses a gapless metal oxide lightning arrester, primarily applied in high-speed railway systems. The high-speed rail lightning arrester exhibits excellent nonlinear volt-ampere characteristics, presenting a high-resistance insulation state under normal operating voltage. When subjected to lightning or switching overvoltage surges, it enters a low-resistance state, rapidly discharging surge currents into the ground, protecting parallel electrical equipment from damage and ensuring insulation safety.

Features

Overvoltage Protection Characteristics

When overvoltage occurs in the power system, the lightning arrester can quickly respond, limiting the overvoltage within the tolerable range of the equipment, thereby protecting the electrical equipment and systems of the EMU train from damage.

High Mechanical Strength

It is manufactured with high-strength, corrosion-resistant materials and undergoes rigorous mechanical strength testing to ensure stability and reliability under various harsh operating conditions.

Strong Resistance to Vibration and Impact

Through reasonable structural design and material selection, its natural frequency and damping ratio are improved, reducing the impact of vibration on the equipment and enhancing its shock resistance.

Stable Insulation

Rigorous control over insulation material selection, insulation structure design, and insulation performance testing ensures stable insulation performance of the EMU train lightning arrester.

 

Technology parameters

Project

Value

rated voltage(AC)

27.5

Weight(KG)

14

Volume φ(mm)

205*465

Partial Discharge(pc)

≤10

Rated Repetitive Charge Transfer Qrs(C)

≥2.0

 


Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Intelligent Surge Arrester Monitoring: Trends, Challenges & Future Outlook
    1. Current Status and Shortcomings of Online MonitorsCurrently, online monitors are the most commonly used tools for surge arrester monitoring. While they can detect potential defects, they have significant limitations: manual on - site data recording is required, precluding real - time monitoring; and post - collection data analysis adds to operational complexity. IoT - based intelligent monitoring overcomes these issues—collected data is uploaded via the IoT to processing platforms,
    07/31/2025
  • Surge Arrester Handover & Live Testing Technologies for Reliable Power Grid Operation
    1. Overview of Surge Arrester Handover Test Technology1.1 Necessity of Handover TestThe handover test is a crucial step in ensuring the performance and safe operation of surge arresters within power systems. For power systems with voltage levels at 220 kV and below, surge arresters play a core role in protecting electrical equipment from damage caused by overvoltages and lightning strikes. However, during the process from the arrester leaving the factory to its actual operation after installatio
    07/31/2025
  • Surge Arrester Failure Analysis and Prevention: Key Causes of 10 kV Distribution Arresters' Malfunctions
    1. IntroductionDuring power system operation, main equipment faces threats from internal and atmospheric overvoltages. Surge arresters, especially metal oxide arresters (MOAs) with excellent nonlinear volt - ampere characteristics, are key for protection due to their good performance, large current - carrying capacity, and strong pollution resistance. However, long - term exposure to power frequency voltages, along with component quality, manufacturing processes, and external environments, makes
    07/30/2025
  • Advanced Online Monitoring System for Zinc Oxide Surge Arresters: Key Technologies and Fault Diagnosis
    1 Architecture of the Online Monitoring System for Zinc Oxide Surge ArrestersThe online monitoring system for zinc oxide surge arresters comprises three layers: the station control layer, bay layer, and process layer. Station Control Layer: Includes a monitoring center, a Global Positioning System (GPS) clock, and a B - code clock source. Bay Layer: Consists of online monitoring Intelligent Electronic Devices (IEDs). Process Layer: Features monitoring terminals for Potential Transformers (PTs) a
    07/30/2025
  • Enhancing Surge Arrester Online Monitors: Key Improvements for Precision, Fault Diagnosis, and Reliability
    1 Significance of Surge Arrester Online Monitors1.1 Enhance Power System Safety, Reduce Lightning DamageDuring lightning strikes, surge arresters play a core role in discharging overvoltage. Online monitors ensure arrester stability, detect potential faults in real - time, and trigger alarms for timely intervention—effectively reducing lightning - induced damage to power equipment and systems, and maintaining stable operation.1.2 Real - Time Status Monitoring, Improve Maintenance Effic
    07/30/2025
  • Real-Time Monitoring of Surge Arresters in 10kV GIS Cubicles: Enhancing Railway Power System Safety
    1 Research BackgroundMetal - oxide surge arresters, sealed in cabinets, bear system voltage continuously, risking aging failures, even breakdowns/explosions causing electrical fires. Thus, regular inspection/maintenance is needed. Traditional 3–5 - year - cycle detection (power cut, arrester removal for tests; reinstallation if replaced) poses safety risks and faces space/environment - based standard - grasping difficulties.2 Monitoring Principle of 10kV GIS Cabinet Surge ArresterTo en
    07/30/2025

Related Solutions

  • Implementation Scheme for Installing Lightning Arresters or Voltage Transformers in Gas-Insulated Ring Main Units
    According to insulation type, ring main units (RMUs) can be categorized as gas-insulated or air-insulated. The former installs primary circuit components in a sealed metal enclosure filled with low-pressure gas (primarily SF₆ or mixed gases) as the insulating medium, using cable terminals for incoming and outgoing lines. Due to superior insulation, compact size, and modular design, they are widely used in 10kV outdoor distribution substations and prefabricated transformer stations. However, thei
    08/16/2025
  • Lightning Arrester Fault Rapid On-Site Disposal Solution
    I. Disposal ObjectivesUpon detecting a lightning arrester fault, conduct rapid, safe, and effective on-site disposal to isolate the faulty equipment. Minimize threats to power grid operation, equipment safety, buildings, and personnel. Create conditions for subsequent detailed maintenance or replacement.II. Handling Principles Safety First: Always prioritize personal safety; strictly adhere to electrical safety regulations. Rapid Response: Initiate the disposal procedure immediately upon detecti
    08/01/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.