• DS5A 40.5kV 72.5kV 126kV High voltage disconnect switch
DS5A 40.5kV 72.5kV 126kV High voltage disconnect switch
discuss personally
Model
DS5A-126/3150-50
DS5A-126/2500-50
DS5A-126/2000-50
DS5A-126/1250-50
DS5A-72.5/4000-40
DS5A-72.5/3150-40
DS5A-72.5/2500-40
DS5A-72.5/2000-40
DS5A-72.5/1250-40
DS5A-40.5/4000-20
DS5A-40.5/2500-20
DS5A-40.5/2000-20
DS5A-40.5/1250-20
DS5A-40.5/630-20
Basic info
Brand ROCKWILL
Model NO. DS5A 40.5kV 72.5kV 126kV High voltage disconnect switch
Rated voltage 126kV
Rated normal current 3150A
Rated frequency 50/60Hz
Rated peak value withstand current 125kA
Rated short-time withstand current 50kA
Series DS5A
Product Detail

Product introduction:

DS5A Switch Disconnector Is a kind of outdoor HV electricity transmission equipment’s al three-phase AC frequency of 50Hz/60Hz. It Is used for breaking or connecting HV lines under no loads so that the power lines can be changed and connected and the way the electricity runs is changed. In addition it can be used to exercise safe eleclrica.1 insulation for such HV electric apparatuses as bus and break.

This product has two posts with horizontal open breaks. It Is open able In the middle and accessible to the grounding switch on one side or two sides. 90°drive's isolating switch and grounding switches adopt cs11 manual operating mechanism to execute the tri-pole linkage;180°drive's isolating switch adopts CS11 manual operating mechanism or CS14g manual to execute the tri-pole linkage; the grounding Switch adopts CS11 manual actuator to realize the tri-pole linkage.

DS5A Switch Disconnector comprises three single poles and actuator. Each single pole is made of a base, post insulator and conductive part. Two rotating post insulators are installed at a base with two insulators forming an angle of 50° and arranged in V shape. The contact finger arms and contact head arms of the conductive knife switch are separately fixed onto the end of the Insulating post.

The actuator drives one side of the insulating post to revolve, and drives the other side of the insulating post to rotate reversely by 90° through the angular wheel or link lever, so that the knife switch will be in circumgyration to realize the opening and closing of the Switch Disconnector. A horizontal insulating open break will appear at the closing moment.

Main characteristic:

  • The conductive arm made of rectangular Al-alloy pipes is characterized by high strength, light, weigh, large radiation area and strong resistance against corruption.
  • DS5A adopts particular copper alloy to develop the self-contained contact. The contact point is tightened by the elastic force of the contact itself. The contact spring is eliminated to avoid possible drop of the contact in gripping force due to the spring's corrosion and shunting, possible heating and annealing, possible increment in contact resistance, and possible vicious cycle of the growing heat or the contact The contact is made of curved copper plate, forming a large connection area with the conductive arm. In the opening and dosing processes, there is a short trip of friction between the contact and the finger and the required operating force is small. The conductive part has been acknowledged by the Chinese competent authority as a new and practical patent.(Patent No.: 2103 2 20022.6)
  • The rotating parts of the Switch Disconnector are designed to be free of maintenance. The rotating base is designed into a closure structure which denies the access of moisture, dust and harmful gases so that the low-temperature lubricating cream within the bearing will not run off or harden. Within the bearing base are thrust ball bearing and radial ball bearing, both of which will share the gravity and horizontal component of the Switch Disconnector so that the operating torque will not increase after the long-term operation of the disconnect switch
  • The mechanical interlock between the primary switch and earthing switch is directly installed onto the principal axis of the primary switch and the revolution axis of the earthing switch. The interlock Is direct and reliable, eliminating the structurally complex gearbox. It also facilitates easy adjustment In the field erection and avoids the corrosion of the gear box.
  • Provide one-key sequential control "double confim1ation" function expansion

Main technical parameters:

GW5A-parameters.png

Order notice :

Product model, current, rated short-time withstand current and creepage distance must be specified at the goods-ordering time;

The Switch Disconnector offers several options of grounding (no, left, right, both left and right). Unless otherwise specified, the goods suppled will be considered as providing the option of right grounding;

The operating mechanism, voltage and the number of contacts for auxiliary switch;

Methods of installation: horizontal installation, installation by the iodination of 25",side installation. Unless otherwise specified, the horizontal installation will be taken as default;

Specify the type of power and voltage degree for the electromagnetic lock of the actuator.

 

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Ensuring Reliability: A Deep Dive into Transformer Maintenance
Ensuring Reliability: A Deep Dive into Transformer Maintenance
IntroductionElectric transformers are the backbone of modern power distribution systems, silently enabling the reliable delivery of electricity to homes, businesses, and industries. As these critical assets age and the demand for uninterrupted power grows, the importance of diligent transformer maintenance has never been greater. This essay explores the essential role of transformer maintenance, highlighting the value of proactive care, the impact of advanced diagnostic technologies, and the tra
Vziman
09/03/2025
How does a transformer work?
How does a transformer work?
Transformer Operation PrincipleA transformer is an electrical device that operates on the principle of electromagnetic induction to transfer electrical energy from one circuit to another. It enables the adjustment of voltage levels within an alternating current (AC) system, either stepping up (increasing) or stepping down (decreasing) voltage while maintaining the same frequency.Working Principle:Basic ComponentsA transformer consists of two coils, known as windings—the "primary winding" connect
Rockwell
09/03/2025
Constant testing of high-voltage cable lines
Constant testing of high-voltage cable lines
1. Definition of High-Voltage Cable Line Constant TestingHigh-voltage cable line constant testing refers to the systematic measurement, using specialized instruments, of electrical parameters such as resistance, inductance, capacitance, and conductance before a cable line is commissioned or after major maintenance. The aim is to obtain fundamental data characterizing the electromagnetic properties of the cable, serving as a critical testing phase that provides accurate parameter support for powe
Oliver Watts
09/03/2025
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
1.Work Environment Requirements and Safeguard MeasuresBased on technical requirements for cable equipment storage, laying, transportation, laying, transposition, testing, and cable terminations, the project owner and construction units have conducted extensive trials and implemented protective measures regarding ambient temperature, humidity, bending radius, traction control, and route optimization. These measures ensure high-voltage cable quality and on-site safety under harsh winter conditions
James
09/03/2025
Withstand voltage test of high-voltage cables
Withstand voltage test of high-voltage cables
Withstand voltage test is an insulation test, but it is a destructive test that can reveal insulation defects difficult to detect in non-destructive testing.The test cycle for high-voltage cables is three years, and it must be conducted after non-destructive tests. In other words, the withstand voltage test is performed only after all non-destructive tests have been passed.Most high-voltage cables used today are cross-linked polyethylene (XLPE) cables, which can have large cross-sections and cov
Oliver Watts
09/03/2025
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
I. Introduction to Cable Grounding Loop CurrentCables rated 110 kV and above use a single-core structure. The alternating magnetic field generated by the operating current induces a voltage on the metallic sheath. If the sheath forms a closed circuit through the earth, a grounding loop current will flow on the metallic sheath. Excessive grounding loop current (loop current exceeding 50 A, more than 20% of the load current, or a ratio of maximum-to-minimum phase current greater than 3) not only a
Felix Spark
09/03/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!