Customization 6kV 10kV 20kV 22kV 33kV Oil-Immersed High-Voltage Side-Mounted Grounding Transformer source manufacturer

  • Customization 6kV 10kV 20kV 22kV 33kV Oil-Immersed High-Voltage Side-Mounted Grounding Transformer source manufacturer

Key attributes

Brand Rockwell
Model NO. Customization 6kV 10kV 20kV 22kV 33kV Oil-Immersed High-Voltage Side-Mounted Grounding Transformer source manufacturer
Rated voltage 24kV
Rated frequency 50/60Hz
Cooling mode ONAN
Series JDS

Product descriptions from the supplier

Description

Description

As the earliest specialized manufacturer of grounding transformers in China, we have built a complete independent industrial chain through decades of technological accumulation. Leveraging the long-term verified reliability of our products and our continuous innovation capabilities, we consistently lead the upgrading of industry standards, serving as a technological pioneer in the field of power safety equipment.

Earthing transformers are specially designed transformers. Their core function is to provide an artificial neutral point for power grids where the neutral point is either ungrounded or grounded through high impedance. This enables the neutral point to be grounded via an arc suppression coil or a small resistor.

The oil-immersed, high-voltage bushing side-mounted type grounding transformer (commonly referred to in the industry as the "high-voltage side-mounted grounding transformer") is a specialized variant. As the name implies, the high-voltage bushings (i.e., the terminals of the high-voltage winding) of this type of transformer adopt a side-mounted design, positioned on the side of the transformer tank rather than on the top.

This structural design significantly reduces the overall installation height of the equipment, making it particularly suitable for space-constrained installations, such as indoor GIS (Gas-Insulated Switchgear) rooms, compact substations, and retrofit projects in existing substations.

Features

  • Space Optimization: The side-exit bushings significantly reduce the overall equipment height, enabling easy adaptation to low-clearance spaces or retrofit requirements in existing substations, saving civil engineering costs.

  • Flexible Grounding: Provides a stable neutral point, allowing flexible connection to a resistor cabinet / arc suppression coil. This effectively limits ground fault current, suppresses overvoltages, and enhances system safety and power supply continuity.

  • High Reliability:
    Impact Resistance: Designed to withstand the impact of unbalanced currents and zero-sequence currents generated by system single-phase-to-ground faults.
    Low Losses: Employs high-quality silicon steel cores and advanced manufacturing processes to ensure low no-load and load losses.
    Robust Insulation: Features a reliable high-voltage insulation structure with low partial discharge levels.
    Excellent Protection: High enclosure protection rating (IP), providing effective dust and moisture resistance.

  • Simplified Installation & Maintenance: Compact structure combined with the side-exit wiring design optimizes both on-site installation and subsequent maintenance operations.

Main Technical Parameters

Some of these earthing transformers cover voltage levels including:3.3kV / 6kV / 11kV / 15kV / 20kV / 22kV / 30kV / 33kV / 34.5kV / 36kV / 44kV / 66kV / 88kV / 110kV / 132kV / 145kV / 150kV / 220kV / 275kV / 330kV / 400kV, etc. The current withstand time ranges from 1s, 2s, 3s, 5s, 6s, 8s, 9s, 10s, 30s, 60s, 1hour to 2hours, and customization is available.

Parameter

Specification

Transformer type

Earthing transformer

Reference standard

IEC 60076

Rated power

334kVA

Rated voltage

6kV 10kV 20kV 22kV 33kV 

Number of phase

3

Vector of group

ZN

Cooling method

ONAN

Winding material

Copper

Cooling medium

Mineral oil

Zero phase sequence impedance at 75℃

58.62 Ohms/phase

Main Application Areas

  • Power Generation Systems: Neutral grounding for auxiliary power systems in thermal/nuclear/hydroelectric plants

  • New Energy Stations: Grounding protection for collection systems in photovoltaic/wind/storage power plants

  • Industrial Power Distribution: Grounding for high-voltage motors and distribution systems in petrochemical, metallurgical, and mining industries

  • Transportation Power Systems: Grounding for railway traction substations, metro main substations, and port shore power systems

  • Special Scenarios: Grounding systems for precision power supply in data centers, hospitals, and laboratories


FAQ
Q: What is the relationship between the short-time capacity and short-circuit withstand time of an earthing/grounding transformer?
A:
The two are core parameters that restrict each other, following the inverse proportional relationship of "for the same equipment, the longer the withstand time, the smaller the short-time capacity" — because short-time capacity is calculated based on the thermal effect of fault current. Under the same fault current, the longer the withstand time, the more heat the equipment absorbs. To avoid insulation damage due to overheating, the rated short-time capacity must be reduced. For example, a 110kV earthing/grounding transformer has a short-time capacity of 5MVA under 30-second withstand time; if the withstand time is increased to 60 seconds, its short-time capacity may drop to about 3MVA (specifically, it must be implemented in accordance with the manufacturer's technical manual).
Q: How to coordinately determine the short-time capacity and short-circuit withstand time parameters of an earthing/grounding transformer during selection?
A:
Selection suggestions: The resistance value of the earthing resistor must be calculated in combination with the zero-sequence impedance of the earthing/grounding transformer, usually satisfying "earthing resistance R ≤ Uₚₕ/Iₚₑₐₖ" (Uₚₕ is the system phase voltage, Iₚₑₐₖ is the maximum short-time fault current allowed by the earthing/grounding transformer). At the same time, it must comply with the resistance value requirements for different grounding systems in the standard DL/T 621-1997 "Earthing of AC Electrical Installations".
Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 60000m² Total staff: Highest Annual Export(usD): 100000000
Workplace: 60000m²
Total staff:
Highest Annual Export(usD): 100000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026

Related Solutions

Related Free tools
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now