Customization 145kV/138kV/230kV or Other Live tank Vacuum Circuit-Breaker

  • Customization 145kV/138kV/230kV or Other Live tank Vacuum Circuit-Breaker

Key attributes

Brand ROCKWILL
Model NO. Customization 145kV/138kV/230kV or Other Live tank Vacuum Circuit-Breaker
Rated voltage 138kV
Rated normal current 4000A
Rated frequency 50/60Hz
Rated short circuit breaking current 40kA
Series RHBZ

Product descriptions from the supplier

Description

Product Overview

The RHB series vacuum circuit breaker is designed specifically for outdoor/indoor medium and high voltage scenarios. It adopts vacuum arc extinguishing technology and high-strength insulation structure, relying on the excellent insulation arc extinguishing performance of the vacuum medium. The arc extinguishing speed is fast (<10ms), and it can efficiently cut off fault current and load current. The product has the core advantage of 'full range customization', covering standard voltage levels of 11kV-252kV, supporting non-standard voltage (such as 22kV/44kV/132kV, etc.) and current customization, accurately matching personalized needs such as new and old power grid renovation, industrial distribution, and new energy access. It is the core equipment for improving the safety and stability of the power system.

About customization

We offer full customization services for voltage classes, including single-phase, two-phase, and three-phase configurations, as well as non-standard voltage/current solutions. Examples of available voltage and current specifications include 1250 A 75 kV, 3200 A 46 kV, 60 kV, 69 kV, and 75 kV (we support customization ranging from 12 kV to 252 kV for voltage. Regardless of your power grid's voltage specifications, we tailor the circuit breaker for seamless integration.

All products are fully assembled and tested at our factory before being shipped directly to your site--no disassembly of key components is required. This eliminates the need for on-site high-voltage testing, significantly saving you time and costs.

Features

  • Flexible customization service: Supports standard (12kV/33kV/126kV, etc.) and non-standard (22kV/69kV/230kV, etc.) voltage customization, with a voltage range of 11kV-252kV and a current adaptation of up to 4000A. It is compatible with single-phase/two-phase/three-phase configurations, perfectly meeting different power grid architectures and industrial needs.

  • Efficient vacuum arc extinguishing: Adopting a vacuum arc extinguishing chamber structure, the vacuum degree is ≤10 ⁻⁴ Pa, and the arc extinguishing is free of medium pollution. The rated short-circuit withstand current is up to 63kA, suitable for frequent operation scenarios, and the electrical life exceeds 10000 times.

  • Environmentally friendly and pollution-free: No need for greenhouse gases such as SF6, no leakage risk, meets environmental standards, avoids gas related safety hazards, reduces environmental impact, and adapts to the development needs of green electricity.

  • Ultra long maintenance cycle: The vacuum arc extinguishing chamber has excellent sealing performance, stable mechanical structure, and a maintenance cycle of up to 30 years, greatly reducing operation and maintenance frequency and long-term operating costs, and is suitable for unmanned substations.

  • Strong environmental adaptability: It can operate stably in a wide temperature range of -30 ℃~+40 ℃, withstand high altitude, Class IV air pollution, wind resistance pressure, and anti icing thickness of up to 20mm, suitable for harsh outdoor scenes and compact indoor layouts.

  • Precise safety monitoring: Equipped with mechanical status monitoring and overcurrent protection devices, real-time feedback on equipment operation status, timely warning of abnormal situations, and avoiding insulation failure and mechanical failure risks.

  • Low partial discharge and high insulation: The partial discharge capacity is less than 5PC, and the insulation performance is excellent. After lightning impulse testing and power frequency withstand voltage testing, it ensures long-term operation without insulation discharge hazards and is suitable for stable operation at high voltage levels.

  • Compact and flexible structure: Adopting modular design, it is compact in size and light in weight. The outdoor version is supported by porcelain pillars, and the indoor version is suitable for cabinet installation. The layout is reasonable, the anti-interference ability is strong, and the installation space is saved.

Technical parameters

Item

Unit

Parameter

customization of Rated voltage

kV

11kV/12kV/13.8kV/15kV/22kV/33kV/44kV/60kV/63kV/

66kV/69kV/88kV/115kV/123kV/125kV/126kV/132kV/

138kV/145kV/150kV/170kV/184kV/204kV/220kV/

225kV/230kV/245kV/252kV

Rated frequency

Hz

50/60

customization of Rated current

A

up to 4000

Rated short-time withstand current,  up to 3 s

kA

up to 63

Rated peak withstand current

kA

42 to 900

Rated short-duration power-frequency withstand voltage( 1 min)

kV

48 to 960

Power-frequency withstand voltage( 1 min ),across open contacts

kV

75 to 1950

Rated lightning impulse withstand voltage 1.2/50  us

kV

85 to 2100

Rated lightning impulse withstand voltage  1.2/50  us, across open contacts

kV

250

Rated filling pressure (abs. at 20℃) circuit-breaker/other components

Mpa

0.5

Minimum functional pressure (abs. at 20℃) circuit-breaker/other components

Mpa

0.4

Temperature range (ambient)

-30...+40

Type of installation

 

outdoor

Partial discharge capacity

PC

<5

SF6 leakage rate per year

 

<0.5%

Maintenance cycle

Year

30

Application scenarios

  1. Large hub substation : Suitable for medium and high voltage distribution network circuits of 220kV+key hub substations, customized voltage levels can seamlessly integrate into the existing power grid architecture, achieve precise control and protection of the main power supply circuit, and ensure stable operation of the core nodes of the power grid.

  2. New Energy Grid Connection System: Provide customized voltage solutions for the medium and high voltage grid connection needs of distributed photovoltaic and small and medium-sized wind power projects, adapt to the fluctuating load characteristics of new energy projects, and ensure the smooth integration of renewable energy into the distribution network.

  3. Industrial High Voltage Power System: Suitable for heavy industries such as metallurgy, chemical engineering, and building materials, customized products are designed for the special voltage and frequent operation requirements of high-power equipment and continuous production lines. With stable performance and adaptability, it ensures continuous power supply for industrial production.

Documentation Resource Library
Restricted
RHB Hybird Switchgear Catalog
Catalogue
English
Consulting
Consulting
FAQ
Q: What Non-standard voltage level customization services can be provided for this tank-type circuit breaker?
A:
We provide customized services for the following voltage levels, including but not limited to11kV/12kV/13.8kV/15kV/22kV/33kV/44kV/60kV/63kV/66kV/69kV/88kV/
115kV/123kV/125kV/126kV/132kV/138kV/145kV/150kV/170kV/184kV/204kV/220kV/
225kV/230kV/245kV/275kV/330kV/345kV/400kV/756kV/800kV.
Q: What is the difference between vacuum circuit breaker and SF6 circuit breaker?
A:
  1. Their core difference is arc-extinguishing media: Vacuum breakers use high vacuum (10⁻⁴~10⁻⁶Pa) for insulation and arc extinction; SF₆ breakers rely on SF₆ gas, which adsorbs electrons well to quench arcs.
  2. In voltage adaptation: Vacuum breakers fit medium-low voltages (10kV, 35kV; some up to 110kV), rarely 220kV+. SF₆ breakers suit high-ultra high voltages (110kV~1000kV), mainstream for ultra-high voltage grids.
  3. For performance: Vacuum breakers extinguish arcs fast (<10ms), have 63kA~125kA breaking capacity, suit frequent use (e.g., power distribution) with long life (>10,000 cycles). SF₆ breakers excel in stable large/inductive current breaking but work less frequently, needing insulation recovery time post-extinction.
  4. Compared to SF6 gas circuit breakers, vacuum circuit breakers can achieve zero greenhouse gas emissions and are more environmentally friendly because the arc extinguishing device does not contain any gas
Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding Electrodes
    Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding ElectrodesWhen the grounding electrode of an Ultra-High-Voltage Direct Current (UHVDC) transmission system is located close to a renewable energy power station, the return current flowing through the earth can cause a rise in ground potential around the electrode area. This ground potential rise leads to a shift in the neutral-point potential of nearby power transformers, inducing DC bias (or DC offset) in their
    01/15/2026
  • HECI GCB for Generators – Fast SF6 Circuit Breaker
    1.Definition and Function1.1 Role of the Generator Circuit BreakerThe Generator Circuit Breaker (GCB) is a controllable disconnect point located between the generator and the step-up transformer, serving as an interface between the generator and the power grid. Its primary functions include isolating generator-side faults and enabling operational control during generator synchronization and grid connection. The operating principle of a GCB is not significantly different from that of a standard c
    01/06/2026
  • Distribution Equipment Transformer Testing, Inspection, and Maintenance
    1.Transformer Maintenance and Inspection Open the low-voltage (LV) circuit breaker of the transformer under maintenance, remove the control power fuse, and hang a “Do Not Close” warning sign on the switch handle. Open the high-voltage (HV) circuit breaker of the transformer under maintenance, close the grounding switch, fully discharge the transformer, lock the HV switchgear, and hang a “Do Not Close” warning sign on the switch handle. For dry-type transformer maintenance: first clean the porcel
    12/25/2025
  • How to Test Insulation Resistance of Distribution Transformers
    In practical work, insulation resistance of distribution transformers is generally measured twice: the insulation resistance between thehigh-voltage (HV) windingand thelow-voltage (LV) winding plus the transformer tank, and the insulation resistance between theLV windingand theHV winding plus the transformer tank.If both measurements yield acceptable values, it indicates that the insulation among the HV winding, LV winding, and transformer tank is qualified. If either measurement fails, pairwise
    12/25/2025
  • Design Principles for Pole-Mounted Distribution Transformers
    Design Principles for Pole-Mounted Distribution Transformers(1) Location and Layout PrinciplesPole-mounted transformer platforms should be located near the load center or close to critical loads, following the principle of “small capacity, multiple locations” to facilitate equipment replacement and maintenance. For residential power supply, three-phase transformers may be installed nearby based on current demand and future growth projections.(2) Capacity Selection for Three-Phase Pole-Mounted Tr
    12/25/2025
  • Transformer Noise Control Solutions for Different Installations
    1.Noise Mitigation for Ground-Level Independent Transformer RoomsMitigation Strategy:First, conduct a power-off inspection and maintenance of the transformer, including replacing aged insulating oil, checking and tightening all fasteners, and cleaning dust from the unit.Second, reinforce the transformer foundation or install vibration isolation devices—such as rubber pads or spring isolators—selected based on the severity of vibration.Finally, strengthen sound insulation at weak points of the ro
    12/25/2025

Related Solutions

  • Intelligent Operation Solution for 12kV Vacuum Circuit Breakers: Integrating Real-time Monitoring & Lifetime Optimization
    Ⅰ. Equipment Operation & MaintenanceIntelligent Monitoring System Integration​Multi-parameter Real-time Monitoring: Embedded sensors (temperature, displacement, Hall effect current sensors) track contact temperature rise, mechanical characteristics (opening/closing speed, overtravel), coil current, and partial discharge signals. Data undergoes preprocessing via edge computing prior to cloud upload.​Lifetime Prediction Model: Dynamically evaluates remaining lifespan using electrical wear data
    06/10/2025
  • SF6 Circuit Breaker Solutions for Outdoor Installation (Anti-Pollution & Seismic Resistance)
    I.Core Challenges in Outdoor Installation​In high-voltage transmission and distribution systems, SF6 circuit breakers are exposed to complex outdoor environments for extended periods, facing the following critical issues:​Pollution & Insulation Degradation​Dust, salt fog, and industrial pollutants in outdoor environments easily adhere to equipment surfaces. In coastal or industrial areas, pollution levels may reach ​Class IV, resulting in insufficient creepage distance and triggering ​flasho
    05/12/2025
  • 12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact Design
    12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact DesignⅠ. Executive Summary​Southeast Asia faces rapidly growing electricity demand alongside environmental challenges including high temperatures, humidity, salt spray corrosion, and grid instability. This solution recommends ​Solid Insulated Pole-Mounted Vacuum Circuit Breakers (VCB)​​ featuring ​high reliability, ​compact design, and ​smart monitoring. Tailored for tropical climates and industrial scenarios, it
    06/10/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file

IEE Business will not sell or share your personal information.

Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.