• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


Customization 145kV/138kV/230kV or Other Dead tank Vacuum Circuit-Breaker

  • Customization 145kV/138kV/230kV or Other Dead tank Vacuum Circuit-Breaker

Key attributes

Brand ROCKWILL
Model NO. Customization 145kV/138kV/230kV or Other Dead tank Vacuum Circuit-Breaker
Rated voltage 138kV
Rated normal current 3150A
Rated frequency 50/60Hz
Rated short circuit breaking current 31.5kA
Series RHDZ

Product descriptions from the supplier

Description

Product Overview

The RHD Series Vacuum Circuit Breaker redefines high-voltage power control with 'tailor-made customization' and cutting-edge vacuum technology. It features a sealed vacuum interrupter (vacuum degree ≤10⁻⁴Pa) that delivers lightning-fast arc extinction (<10ms) --no SF6, no pollution, just eco-friendly, efficient current interruption. Covering standard 40.5kV-252kV grades and supporting full non-standard voltage/current customization, it perfectly fits your grid upgrade, new construction, or special industrial needs, standing as the trusted choice for high-demand high-voltage scenarios.

About Customization

We offer all-round customization to match your exact requirements: single-phase/two-phase/three-phase configurations, plus non-standard voltage (12kV-252kV) and current (1250A-6300A) solutions. Examples include 1250A 75kV, 3200A 46kV, 60kV, 69kV, and 75kV -- whatever your grid specs, we craft a seamless-fit breaker.

Every unit is fully assembled and rigorously tested at our factory before direct delivery. No on-site disassembly or high-voltage testing needed -- saving you valuable time and costs.

Features

  • 9-Grade Seismic Resistance:Low-center-of-gravity design withstands up to 9-degree earthquake intensity, ensuring rock-solid performance in seismic-prone areas -- a proven advantage of the RHD series.

  • Ultra-Efficient Arc Extinction & Long Lifespan:Vacuum medium's superior arc-extinguishing capability enables ≥50kA rated short-circuit breaking current. Boasting over 10,000 electrical operations and 10,000 mechanical cycles, it slashes replacement and maintenance costs.

  • Zero-Pollution Eco-Friendly Design:No SF6 or greenhouse gases -- eliminates leakage risks and environmental impact, aligning with global green energy trends and strict eco-standards.

  • Modular Flexibility for Any Layout:On-demand built-in current transformers (up to 15 for measurement/protection) and standardized module interfaces enable flexible combinations. Ideal for space-constrained substations and diverse design needs.

  • Extreme Environmental Adaptability:Thrives in harsh conditions: -40℃ to +55℃ ambient temperature, 32K daily temperature difference, 3,000m altitude, Class IV air pollution. Resists 700Pa wind pressure (34m/s) and 20mm icing -- reliable anywhere.

  • Comprehensive Safety Protection:Anti-mis operation interlocking devices prevent human-error accidents. Pre-delivery lightning impulse tests eliminate insulation discharge risks, ensuring uncompromised quality.

  • Maintenance-Free Spring Mechanism:Oil-free, gas-free spring-operated structure delivers stable performance, low noise, and high reliability -- cutting long-term operational workload to zero.

Technology Parameters

Item

Unit

Parameters

customization of Rated Voltage

kV

11kV/12kV/13.8kV/15kV/22kV/33kV/44kV/60kV/63kV/66kV/

69kV/88kV/115kV/123kV/125kV/126kV/132kV/138kV/145kV/

150kV/170kV/184kV/204kV/220kV/225kV/230kV/245kV/252kV

customization of Rated  current

A

1250 to 6300

Rated frequency

Hz

50/60

1min Power frequency withstand voltage

kV

Max to 460

Lightning impulse withstand voltage

kV

Max to 1050

First open pole factor

 

1.5/1.3/1.55

Rated short circuit breaking current

kA

16 to 63

Rated short - circuit duration

s

4,3

Rated out - of - phase breaking current

 

10

Rated cable charging current

 

10/50/125

Rated peak value withstand current

kA

80/100/125

Rated making current (peak)

kA

80/100/125

Creepage distance

mm/kV

25 - 31

Heater voltage

 

AC220/DC220

Voltage of control circuit

DC

DC110/DC220/DC230

Voltage of energy - store motor

V

DC 220/DC 110/AC 220/DC230

Applied standards

 

GB/T 1984/IEC 62271 - 100

Application Scenarios

  • Large Hub Substations:Perfect for 220kV+ key hub substations, its customized voltage adaptability seamlessly integrates into existing/upgraded grids, safeguarding main power circuits with unbeatable stability.

  • New Energy Grid-Connection Systems:Ideal for wind/solar power base high-voltage connections. Custom specs and eco-friendly design ensure renewable energy smoothly feeds into the main grid -- even for projects with unique voltage demands.

  • Industrial High-Voltage Power Systems:Tailored for metallurgy, chemicals, and other heavy industries with specialized voltage needs. Robust performance and frequent-operation adaptability guarantee uninterrupted power for high-power equipment.

Finished Products Display

Finished Products Display.jpg

Documentation Resource Library
Restricted
RHB Hybird Switchgear Catalog
Catalogue
English
Consulting
Consulting
FAQ for
Q: What Non-standard voltage level customization services can be provided for this tank-type circuit breaker?
A:
We provide customized services for the following voltage levels, including but not limited to11kV/12kV/13.8kV/15kV/22kV/33kV/44kV/60kV/63kV/66kV/69kV/88kV/
115kV/123kV/125kV/126kV/132kV/138kV/145kV/150kV/170kV/184kV/204kV/220kV/
225kV/230kV/245kV/275kV/330kV/345kV/400kV/756kV/800kV.
Q: What are the core differences between live tank circuit breakers and tank circuit breakers?
A:
  1. The core differences between porcelain column circuit breakers and tank circuit breakers—two main structural types of high-voltage circuit breakers—lie in six key aspects.
  2. Structurally, porcelain column types are supported by porcelain insulation pillars, with open-layout components like arc extinguishing chambers and operating mechanisms. Tank types use metal-sealed tanks to encapsulate and highly integrate all core parts.
  3. For insulation, the former relies on porcelain pillars, air, or composite insulating materials; the latter combines SF₆ gas (or other insulating gases) with metal tanks.
  4. Arc extinguishing chambers are mounted on the top or pillars of porcelain columns for the former, while built inside metal tanks for the latter.
  5. In application, porcelain column types suit outdoor high-voltage distribution with a dispersed layout; tank types adapt flexibly to indoor/outdoor scenarios, especially space-constrained environments.
  6. Maintenance-wise, the former’s exposed components enable targeted repairs; the latter’s sealed structure reduces overall maintenance frequency but requires full inspections for local faults.
  7. Technically, porcelain column types offer intuitive structure and strong anti-pollution flashover performance, while tank types boast excellent sealing, high SF₆ insulation strength, and superior resistance to external interference.
Q: What is the difference between vacuum circuit breaker and SF6 circuit breaker?
A:
  1. Their core difference is arc-extinguishing media: Vacuum breakers use high vacuum (10⁻⁴~10⁻⁶Pa) for insulation and arc extinction; SF₆ breakers rely on SF₆ gas, which adsorbs electrons well to quench arcs.
  2. In voltage adaptation: Vacuum breakers fit medium-low voltages (10kV, 35kV; some up to 110kV), rarely 220kV+. SF₆ breakers suit high-ultra high voltages (110kV~1000kV), mainstream for ultra-high voltage grids.
  3. For performance: Vacuum breakers extinguish arcs fast (<10ms), have 63kA~125kA breaking capacity, suit frequent use (e.g., power distribution) with long life (>10,000 cycles). SF₆ breakers excel in stable large/inductive current breaking but work less frequently, needing insulation recovery time post-extinction.
  4. Compared to SF6 gas circuit breakers, vacuum circuit breakers can achieve zero greenhouse gas emissions and are more environmentally friendly because the arc extinguishing device does not contain any gas
Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • A Brief Discussion on the Issues of Converting Reclosers into Outdoor Vacuum Circuit Breakers for Use
    The rural power grid transformation plays an important role in reducing rural electricity tariffs and accelerating rural economic development. Recently, the author participated in the design of several small-scale rural power grid transformation projects or conventional substations. In rural power grid substations, conventional 10kV systems mostly adopt 10kV outdoor auto circuit vacuum reclosers.To save investment, we adopted a scheme in the transformation that removes the control unit of the 10
    12/12/2025
  • A Brief Analysis of Automatic Circuit Recloser in Distribution Feeder Automation
    An Automatic Circuit Recloser is a high-voltage switching device with built-in control (it inherently possesses fault current detection, operation sequence control, and execution functions without requiring additional relay protection or operating devices) and protective capabilities. It can automatically detect the current and voltage in its circuit, automatically interrupt fault currents according to inverse-time protection characteristics during faults, and perform multiple reclosures accordi
    12/12/2025
  • Recloser Controllers: Key to Smart Grid Reliability
    Lightning strikes, fallen tree branches, and even Mylar balloons are enough to interrupt current flow on power lines. That’s why utility companies prevent outages by equipping their overhead distribution systems with reliable recloser controllers.In any smart grid environment, recloser controllers play a critical role in detecting and interrupting transient faults. Although many short circuits on overhead lines can resolve themselves, reclosers help improve service continuity by automatically re
    12/11/2025
  • Application of Fault Diagnosis Technology for 15kV Outdoor Vacuum Automatic Circuit Reclosers
    According to statistics, the vast majority of faults on overhead power lines are transient, with permanent faults accounting for less than 10%. Currently, medium-voltage (MV) distribution networks commonly employ 15 kV outdoor vacuum automatic circuit reclosers in coordination with sectionalizers. This setup enables rapid restoration of power supply after transient faults and isolates faulty line segments in the event of permanent faults. Therefore, it is essential to monitor the operational sta
    12/11/2025
  • Application of 10kV Reclosers and Sectionalizers in Rural Distribution Networks
    1 Current Grid StatusWith the continuous deepening of rural power grid transformation, the health level of rural grid equipment is constantly improving, and power supply reliability basically meets user needs. However, regarding the current grid status, due to funding constraints, ring networks have not been implemented, dual power supplies are unavailable, and lines adopt a single radial tree-like power supply method. This resembles a tree trunk with many branches—meaning the lines have numerou
    12/11/2025
  • What’s the Difference Between a Recloser and a Pole-Mounted Breaker?
    Many people have asked me: “What’s the difference between a recloser and a pole-mounted circuit breaker?” It’s hard to explain in one sentence, so I’ve written this article to clarify. In fact, reclosers and pole-mounted circuit breakers serve very similar purposes—they are both used for control, protection, and monitoring on outdoor overhead distribution lines. However, there are significant differences in the details. Let’s examine them one by one.1.Different MarketsThis may be the biggest dis
    11/19/2025

Related Solutions

  • High-Voltage SF6 Dead Tank Circuit Breaker Solution for Nigeria Power Grid
    1. Project BackgroundAs Africa&rsquo;s most populous nation, Nigeria&rsquo;s power grid has long faced challenges including unstable electricity supply, aging infrastructure, and poor environmental adaptability.In its high-voltage transmission and distribution networks, traditional oil circuit breakers struggle to meet growing demand due to frequent maintenance and vulnerability to humid climates (e.g., reduced insulation performance during rainy seasons).International case studies, such
    05/24/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.