Komplet Sat na 160kA Generator Circuit Breaker na Gaba-gaba

  • Complete Set of Large Capacity 160kA Generator Circuit Breaker

Abubuwa gaba

Muhimmiya ROCKWILL
Model NO. Komplet Sat na 160kA Generator Circuit Breaker na Gaba-gaba
Rated Voltage 24kV
Raitidu kọ̀ọ̀kan 27000A
Siri Circuit Breaker

Bayani na sayen daga mai wuyaci

Sharararwa

Description:

Daga wannan mai suna da zai ya kunshi don jiragen ruwa, thermal power, da kuma nuclear power units tare da generator capacity ta 600-800 megawatts. An sanya rated short-circuit breaking current ta 160 kiloamperes, da kuma an sanya rated peak withstand current ta 440 kiloamperes. A shekarar 2013, an samun shirya a kan China Machinery Industry Federation da kuma an yi amfani da ita a Xiangjiaba project, wanda ya haɗa da localization daban-daban, wanda ya ba China da muhimmiyar tsari a cikin ƙasashen da suke da kyakkyawan da suka yi production da large capacity generator circuit breakers, da kuma koyar da engineering procurement costs don domestic users.

Product Performance:

  • An yi implementation don daɗi na IEC standards masu zamanin.

  • High insulation level: an yi tabbataccen da yake da insulation requirements of the products under the environment of 3,000m above sea level.

  • High long-term flow capacity: an yi natural cooling, ba a yi auxiliary heat dissipation device, the rated flow capacity up to 25,000A. With forced air cooling by fan, the rated flow capacity up to 27,000A.

  • Excellent 0breaking performance: the effective value of Ac component of short-circuit breaking current has is 160kA and the DC component is as high as 87%, which meets the current breaking requirements under various fault conditions.

  • High mechanical reliability: Innovative design of circuit breaker drive ensures that the product can meet the breaking performance under the small input operation power, and realize the mechanical life requirement of operation for 5,000times, Disconnector and earthing switch meet the mechanical life requirement of operation for 10,000 times.

  • Comprehensive safety protection measures: Pressure release device is installed at the top of the circuit breaker. When the gas pressure in the arc extinguishing chamber exceeds 1.2MPa due to an accident, the gas will be released to ensure the safety of the personnel and surrounding equipment. The product design can ensure the stable operation of the power plant.

Product Structure:

  • The product consists of three single poles, and each pole has an individual enclosed metal enclosure mounted on the same chassis.

  • Circuit breaker is equipped with hydraulic spring operating mechanism; The disconnector and earthing switch are equipped with motor operating mechanism; The driving modes are all three-phase mechanical linkage.

  • Each operating mechanism is installed on the side of the product close to the control cabinet.

  • SF6 is used as internal insulation and arc-extinguishing medium for circuit breaker, and adopts self-energy arc extinguishing principle. It is mainly composed of the main contact system, arc extinguishing system and driving system.

  • Air is used as insulation medium to isolate the break of the disconnector, the isolation moving contact adopts telescopic direct-acting structure, and the fixed contact adopts inner and outer two-layer contact finger structures, when closing, both the inner and outer surfaces of the moving contact are in contact with the contact finger, thus ensuring sufficient current capacity. Double guiding devices are used to ensure smooth closing of the moving contact.

  • Air is used as insulation medium to isolate the break of the earthing switch. The fixed contact is installed on the support of the main circuit, and the moving contact is installed on the bottom plate of the single pole enclosure.
    微信图片_20240615104546_修复后.png

Typical applications:
微信图片_20240615104629_修复后.png
微信图片_20240615104649_修复后.png

160kA intelligent generator circuit breaker:
微信图片_20240615104608_修复后.png

160 kA intelligent generator circuit breaker not only has basic protection function, but also integrates potential transformer, current transformer, lightning arrester and other components. Each product is equipped with a set of intelligent on-line monitoring device to realize on-line monitoring of conductor temperature, mechanical characteristics of circuit breaker, SF6 gas condition and so on.
Main technical parameters:

image.png

What are the technical parameters of generator circuit breaker?

Rated Voltage:

  • This is the highest voltage at which the generator circuit breaker can operate normally. For example, for generator circuit breakers in large thermal power plants, the rated voltage may reach 20 - 30 kV or even higher. This parameter must match the rated output voltage of the generator to ensure safe and reliable operation under both normal and fault conditions.

Rated Current:

  • It indicates the maximum current that the generator circuit breaker can carry continuously. The selection of the rated current should be based on the rated capacity of the generator. For instance, a 100 MW generator may have a rated current in the range of several thousand amperes, and the rated current of the generator circuit breaker needs to meet this requirement to ensure it can handle the generator's output current during normal operation.

Short-Circuit Breaking Capacity:

  • This is a critical parameter that measures the ability of the generator circuit breaker to interrupt short-circuit faults. When a short circuit occurs at the generator outlet or on the grid side, the circuit breaker must be able to quickly interrupt the high short-circuit current to prevent the fault from spreading. For example, in large power plants, the short-circuit breaking capacity of the generator circuit breaker may reach tens of kiloamperes or even higher, requiring the breaker to have strong arc-quenching capabilities and good thermal and dynamic stability.

Making Current:

  • The making current refers to the maximum instantaneous current that the circuit breaker can withstand when it is closed. During generator startup or when the grid recovers after a fault, there may be significant inrush currents. The circuit breaker must be able to safely close these currents; otherwise, it could result in issues such as contact welding.


Maimakanta mai inganci
Kayan da ke zuwa
kima mai yiwuwa da wata
Waktu na kirma
100.0%
≤4h
Gaskiya ta hanyar kamfanin
Workplace: 108000m²m² Jami'a nanan mafi girma: 700+ Zama-zama na Farko da aka Fitowa a Shekarar (USD): 150000000
Workplace: 108000m²m²
Jami'a nanan mafi girma: 700+
Zama-zama na Farko da aka Fitowa a Shekarar (USD): 150000000
Aiki
Turanci Masana: Design/Manufakturi/Sallar
Ƙananunan Cigaba: Gwọ́n ọkụ̀ àbálòpà
Mafarkin tsoro na yawan kulle
Kayan aiki na alaka da amfani, yin amfani, gyara-gyaran da kuma pasuwa na kayan karkashin yanayi, suka kentuwa da kaiwansu masu iko, ingantacciyar hankali da kuma amfani mai kyau.
mabudin aikatan kayan dabbobi sun dawo da idoni masu iko da ma'ajiriyya, sannan suka tabbata inganci, kwayoyin uku da na'ibbicci ne daga babban kayan aikin

Makarantar Mai Yawanci

Zan'antar Ilimi

Halayyar Bubuwa

Babu samun mai arliƙi daidai ba? Sai ma'arikin mai arliƙi gane kika. Samun Kwatanti Yanzu
Babu samun mai arliƙi daidai ba? Sai ma'arikin mai arliƙi gane kika.
Samun Kwatanti Yanzu
Aika tambaya
Kwamfuta
Samun IEE Business Application
Yi amfani da IEE-Business app don samun abubuwan aikin, samun halayyin, haɗi da malamai, kuma kai tsauraran takaiddun kasoshin duka lokaci, duka wurin—dole bai karfin takamaltar hulɗin ku na alintakargida da kasuwanci.