| Brand | RW Energy |
| Numero sa Modelo | Automatic Recloser Controller ngadto sa Cebuano: Awtomatikong Pagsarado nga Tagapamahala |
| Naka nga boltahang rated | 230V ±20% |
| Nasodnong peryedyo | 50/60Hz |
| Konsumo sa Electrikidad | ≤5W |
| Versyon | V2.3.3 |
| Serye | RWK-35 |
Mga Pahayag
Ang RWK-35 usa ka intelligent medium Voltage controller nga gigamit sa overhead line grid monitoring aron maprotektahan ang overhead line. Kini mahimong pagbutangan og CW(VB) type vacuum circuit breaker aron maabot ang automatic monitoring, fault analysis ug store event records.
Kini nga yunit naghatag og safe line switching sa mga fault sa power grid ug naghatag og automatic power recovery. Ang serye sa RWK-35 kuyog sa hangtod sa 35kV outdoor switchgear sama sa vacuum circuit breakers, oil circuit breakers, ug gas circuit breakers. Ang RWK-35 intelligent controller gipakompleto ngadto sa line protection, control, measurement, ug monitoring sa Voltage ug current signals nga integrated automation ug control devices sa labas.
Ang RWK usa ka automatic management unit para sa single way/multi ways/ring network/two power sourcing, na-provide og tanang Voltage ug current signals ug tanang function. Ang RWK-35 column switch intelligent controller nagsuporta sa: Wireless (GSM/GPRS/CDMA), Ethernet mode, WIFI, optical fiber, power line carrier, RS232/485, RJ45, ug uban pang form sa communication, ug makapuyo sa uban nga station premises equipment (tulad ni TTU, FTU, DTU, etc.).
Pangunhing Pahayag sa Function
1. Protection relay functions:
1) 79 Auto Reclose (Reclose) ,
2) 50P Instantaneous/Definite-Time Overcurrent (P.OC) ,
3) 51P Phase Time-Overcurrent(P.Fast curve/P.Delay curve),
4) 50/67P Directional Phase Overcurrent (P.OC-Direction mode (2-Forward /3-Reverse)),
5) 51/67P Directional Phase Time-Overcurrent (P.Fast curve/P.Delay curve-Direction mode (2-Forward/3-Reverse)),
6) 50G/N Ground Instantaneous/Definite-Time Overcurrent (G.OC),
7) 51G/N Ground Time-Overcurrent (G.Fast curve/G.Delay curve),
8) 50/67G/N Directional Ground Overcurrent (G.OC- Direction mode (2-Forward/3-Reverse)) ,
9) 51/67G/P Directional Ground Time-Overcurrent (P.Fast curve/P.Delay curve-Direction mode (2-Forward/3-Reverse)),
10) 50SEF Sensitive Earth Fault (SEF),
11) 50/67G/N Directional Sensitive Earth Fault (SEF-Direction mode (2-Forward/ 3-Reverse)) ,
12) 59/27TN Earth Fault Protection With 3RD Harmonics (SEF-Harmonic inhibit enabled) ,
13) 51C Cold Load,
14) TRSOTF Switch-Onto-Fault (SOTF) ,
15) 81 Frequency protection ,
16) 46 Negative- Sequence Overcurrent (Nega.Seq.OC),
17) 27 Under Voltage (L.Under volt),
18) 59 Over Voltage (L.Over volt),
19) 59N Zero-Sequence Over Voltage (N.Over volt),
20) 25N Synchronism-Check,
21) 25/79 Synchronism-Check/Auto Reclose,
22) 60 Voltage unbalance,
23) 32 Power direction,
24) Inrush,
25) Loss of phase,
26) Live load block,
27) High gas,
28) High temperature,
29) hotline protection.
2. Supervision functions:
1) 74T/CCS Trip & Close Circuit Supervision,
2) 60VTS. VT Supervision.
3. Control functions:
1) 86 Lockout,
2) circuit-breaker control.
4. Monitoring Functions:
1) Primary/Secondary Phases and Earth Currents,
2) Phases Current with 2nd Harmonics and Earth Current With 3RD Harmonics,
3) Direction, Primary/Secondary Line and Phase Voltages,
4) Apparent Power and Power Factor,
5) Real and Reactive Power,
6) Energy and History Energy,
7) Max Demand and Month Max Demand,
8) Positive Phase Sequence Voltage,
9) Negative Phase Sequence Voltage & Current,
10) Zero Phase Sequence Voltage,
11) Frequency, Binary Input/Output status,
12) Trip circuit healthy/failure,
13) Time and date,
14) Trip, alarm,
15) signal records, Counters,
16) Wear, Outage.
5. Communication functions:
a. Communication interface: RS485X1,RJ45X1
b. Communication protocol: IEC60870-5-101; IEC60870-5-104; DNP3.0; Modbus-RTU
c. PC software: RWK381HB-V2.1.3,The address of the information body can be edited and queried by PC software,
d. SCADA system: SCADA systems that support the four protocols shown in "b.”.
6. Data Storage functions:
1) Event Records,
2) Fault Records,
3) Measurands.
7. remote signaling remote measuring, remote controlling function can be customized address.
Technology parameters

Device structure


About customization
The following optional functions are available: Power supply rated at 110V/60Hz, cabinet heating defrosting device, battery upgrade to lithium battery or other storage equipment, GPRS communication module,1~2 signal indicators,1~4 protection pressure plates, the second voltage transformer, custom aviation socket signal definition.
For detailed customization, please contact the salesman.
Q: Ano ang recloser?
A: Ang reclosing device usa ka device nga makakita sa automatic detection sa fault current, ug automatic cut off sa circuit kon may fault, ug paghuman perform multiple reclosing operations.
Q: Ano ang function sa recloser?
A: Ginagamit kini sa distribution network. Kon may temporary fault sa line (tulad sa branch touching the line for a short time), ang reclosing device restores power supply pinaagi sa reclosing operation, nga dako kaayo nakatabang sa pagreduce sa outage time ug scope ug nag-improve sa power supply reliability.
Q: Asa ang recloser magdetermine sa type sa failure?
A: Ini monitor nia ang characteristics sama sa magnitude ug duration sa fault currents. Kon permanent ang fault, human sa preset number of reclosing, ang reclosing device will be locked aron iwasan ang further damage sa device.
Q: Asa ang application scenarios sa reclosers?
A: Widespread kini gamiton sa urban distribution network ug rural power supply network, nga effective cope sa various possible line failures ug ensure stable supply of power.