• 40.5kV HV Gas circuit breaker
40.5kV HV Gas circuit breaker
discuss personally
Model
LW36-40.5(W)/T4000-50
LW36-40.5(W)/T4000-40
LW36-40.5(W)/T3150-40
LW36-40.5(W)/T2500-40
LW36-40.5(W)/T2500-31.5H
Basic info
Brand Wone
Model NO. 40.5kV HV Gas circuit breaker
Rated voltage 40.5kV
Rated normal current 2500A
Rated frequency 50/60Hz
Rated short circuit breaking current 40kA
Series LW36-40.5
Product Detail

Product introduction

LW36-40.5 outdoor self-energy HV AC SF6 circuit breaker is an outdoor three-phase HV AC equipment used in electricity grids with altitudes of no more than 3000m, environment temperatures of no less than -40℃, local pollution classes of no higher than Class IV, and AC 50Hz/60Hz with maximum voltage of 40.5kV, it is suitable for the control and protection of HV supply and transformation lines in power station, converting stations, and industrial and mining enterprises. it can also be used as connection circuit breaker.

Main characteristic

LW36-40.5 self-energy HV SF6 circuit breaker is equipped with advanced hot-expansion plus auxiliary pressure gas self-energy arc extinguishing technology and matched with new-type spring actuating mechanism, it has features such as long electrical endurance, small operating power, high electrical and mechanical reliability, high technical parameters, and moderate price. Lt’s main performance features are as follows:

1、High rated technical parameters: rated current 2500A/4000A and rated short circuit breaking current 31.5KA/40KA/50KA.suitable for the opening and closing of large-capacity electricity grids.

2、High electrical reliability

No-load line charging breaking ability and no-load cable charging breaking ability 50/60Hz dual-frequency C2,back-to-back capacitor bank breaking ability 50/60Hz dual-frequency C2, no re-breakdown;

Strong external insulation ability;, suitable for regions with 3000m of altitude or Class lV pollution.

3、High reliability of operating mechanism:

Mechanical endurance: separating and closing for 10000 times without replacing parts; can meet the user' s requirement of continuous running and little maintenance.

New type spring actuating mechanism has few components parts; overall high-strength cast aluminum frame and brake separating and closing spring; and centralized arrangement is adopted for the buffer, compact structure, reliable operation, low noise, and convenient maintenance; suitable for frequent operations.

4、Al exposed parts are made of stainless steel materials or hot-galvanized on the surface for high corrosion resistance.

5、Reliable sealing structure ensures the product annual leakage rates≤0.5%.

6、Four internally attached current mutual inductors for every phase can be installed on the circuit breaker. Microcrystal alloy and high permeability material are adopted for internally attached current mutual inductors. The accuracy of 200A and above current mutual inductors can reach up to Level 0.2 or 0.2S. Reliable electrical screening design is adopted for the cable coils of internally attached current mutual inductors to improve the electric field distribution of the mutual inductors and promote the internal insulation of the product. it can withstand 120kv and 5min working frequency withstand voltage test and the internal insulation is not interfered by the short circuit breaking working conditions, which makes it safe and reliable.

Main technical parameters

1732519731006.png

Order notice 

Model and format of the circuit breaker.

Rated electrical parameters (voltage, current, breaking current, etc.);

Environmental conditions for using (environment temperature, altitude, and environment pollution level);

Rated control circuit electrical parameters (power-storage electromotor rated volage and brake separating and closing cable coil rated voltage);

Names and quantities of spare items needed, parts and special equipment and tools (to be otherwise ordered);

The wire connecting direction of the primary upper terminal.

 


Know your supplier
Wone
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
The safe and economical operation of power transformers is related to the safety, economy, stability, and reliability of the operations of various industries. The limitations of conditions such as the investment economic indicators for its selection, the economic benefits of maintenance and operation, and the adaptability in the new environment (access of distributed power sources, configuration of energy storage, etc.) make it impossible to include comprehensive factors in other aspects.The cap
Leon
07/17/2025
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
1 IntroductionLow - voltage current transformers for metering, with a through - core type epoxy resin structure, are widely used in distribution transformer areas and for small - to - medium - sized industrial and commercial electricity consumption. As a range expander for electric energy metering, their performance directly relates to electricity consumption safety and the accuracy of users' trade calculations. Studying long - term immersion's impact on these transformers is practically signifi
Felix Spark
07/17/2025
What is reactive power measurement?
What is reactive power measurement?
The power which exists in the circuit when the voltage and current are out of phase to each other, such type of power is known as the reactive power. The formula measures the reactive power in the circuitReactive Power Measurement & VarmetersReactive power measurement is critical as it indicates circuit power loss: low reactive power worsens load power factor, increasing system losses. Varmeters (volt-ampere reactive meters) measure reactive power and are categorized by circuit phases:Single
Edwiin
07/17/2025
How to Design and Install a Solar PV System?
How to Design and Install a Solar PV System?
Design and Installation of Solar PV SystemsModern society relies on energy for daily needs like industry, heating, transport, and agriculture, mostly met by non-renewable sources (coal, oil, gas). However, these cause environmental harm, are unevenly distributed, and face price volatility due to limited reserves—driving demand for renewable energy.Solar energy, abundant and capable of meeting global needs, stands out. Standalone PV systems (Fig 1) offer energy independence from utilities.
Edwiin
07/17/2025
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
Low-voltage current transformers, as indispensable measurement and protection devices in power systems, often encounter various faults when used in combination with other power equipment due to environmental factors, equipment linkage issues, and improper installation and maintenance. These faults not only affect the normal operation of power equipment but may also endanger personal safety. Therefore, it is necessary to gain an in-depth understanding of fault types, judgment methods, and prevent
Felix Spark
07/17/2025
What are the monitoring methods and future development trends of low-voltage voltage transformers?
What are the monitoring methods and future development trends of low-voltage voltage transformers?
With the continuous advancement of smart grid technology, intelligent monitoring systems are playing an increasingly important role in preventing and addressing faults in voltage transformers. These modern intelligent monitoring systems can collect key parameters from voltage transformers in real time—such as partial discharge levels, temperature, and oil quality—and use data analysis algorithms to assess the health status of the equipment, enabling early fault warnings and precise l
Echo
07/16/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!