22kV 30kV 33kV 66kV Three phase Oil Immersed Grounding /Earthing Transformer Manufacturer

Add us on Google
  • 22kV 30kV 33kV 66kV Three phase Oil Immersed Grounding /Earthing Transformer Manufacturer

Key attributes

Brand ROCKWILL
Model NO. 22kV 30kV 33kV 66kV Three phase Oil Immersed Grounding /Earthing Transformer Manufacturer
Rated voltage 33kV
Phases Three-phase
Frequency range 50/60Hz
Series JDS
Description

Product Overview

With decades of deep expertise in the field of grounding transformers, we have achieved a full-chain closed loop from core technological breakthroughs to industrial application. Driven by an uncompromising pursuit of reliability and stability, we consistently deliver industry benchmark products, serving as a steadfast supporter and standard leader for the high-standard construction of power grids.

This series of three-phase oil-immersed grounding transformers is specifically designed for medium- and high-voltage power grids with ungrounded or low-current grounded neutral points, covering voltage classes from 22kV to 66kV. Featuring a fully sealed oil-immersed structure, it offers high reliability, strong overload capacity, and long service life. By constructing an artificial neutral point and managing ground fault currents, the product effectively suppresses system overvoltage, enhances the safety and stability of continuous power supply in grids, and is suitable for critical applications such as substations, new energy power stations, and industrial power distribution.

Product Highlights

  • Premium Core:The transformer core is made of high-quality cold-rolled oriented silicon steel sheets with 45° full diagonal joints. The iron yoke is securely clamped with through bolts, and the core columns are tied with fiberglass tape. The core surface is coated with silicone resin adhesive for moisture protection and noise reduction.

  • Superior Winding:The windings are constructed with high-quality copper conductors in a segmented cylindrical structure to enhance interlayer insulation. Vacuum drying technology is applied to ensure excellent electrical performance, high mechanical strength, and minimal partial discharge.

  • Advanced Insulation and Cooling:The oil immersed grounding transformer features a fully sealed tank with corrugated fins for efficient heat dissipation, eliminating the need for an oil storage tank. Oil tanks are sealed with oil-resistant rubber strips to prevent contact with air, preserving the insulating oil quality and extending transformer lifespan. Compact footprint, aesthetic appearance, and maintenance-free design are key benefits.

  • Comprehensive Protection Devices:Equipped with pressure relief valves, gas relays, and oil level gauges for real-time monitoring of oil condition. Temperature control devices support remote transmission, allowing convenient supervision of transformer operating temperature.

Key Specifications

Some of these earthing transformers cover voltage levels including:3.3kV / 6kV / 11kV / 15kV / 20kV / 22kV / 30kV / 33kV / 34.5kV / 36kV / 44kV / 66kV / 88kV / 110kV / 132kV / 145kV / 150kV / 220kV / 275kV / 330kV / 400kV, etc. The current withstand time ranges from 1s, 2s, 3s, 5s, 6s, 8s, 9s, 10s, 30s, 60s, 1hour to 2hours, and customization is available.

Parameter

Specification

Installation

Fixed

Structure

Cabinet

Rated Voltage

22kV 30kV 33kV 66kV

Frequency

50/60Hz

Rated Short Circuit Power (kVA)

Approx. 15,240

Rated Continuous Neutral Current (A)

24.8

Rated Short Time Neutral Current (A)

>800

Rated Short Time Duration (s)

20

Vector Group

Zig-Zag

Packaging

Naked

Origin

China

Production Capacity

100 sets/month

HS Code

8537209000

Technical Parameters

  • Transformer Type: Oil Immersed

  • Connection Groups: ZN (Zigzag)

  • Rated Voltage: 36kV

  • Rated Current: 3000A

  • Short Time Duration: 10s / 30s / 60s or customized

  • Cooling Method: ONAN, ONAF, AN, AF

  • Installation: Indoor / Outdoor

  • Ambient Temperature Range: -40℃ ~ +40℃

  • Standards Compliance: IEC 60076-6, IEC 60076-1, IEEE

  • Enclosure Options: Transformer cabinet with customizable IP ratings, optional CT, VT, and isolation switch

Notes

  • Neutral short time current I0 = IG

  • Neutral zero-sequence impedance Z0 = Phase impedance / 3

  • ±5% off-load tap changer

  • Confirm Z0 value before production if not self-limiting

  • Z0 tolerance ≤10%

Rockwill 33kV Oil Immersed Grounding Transformers combine advanced engineering and strict quality control to deliver dependable grounding solutions for power networks worldwide. For inquiries and customization, please contact us.

Solutions - Earthing Transformer Manufacturer

Case Studies - Earthing Transformer Manufacturer

Related Blogs - Earthing Transformer Manufacturer

Documentation Resource Library Earthing Transformer Manufacturer

Rockwill Electric Group Profile
Public
Rockwill Electric Group Profile Rockwill Electric Group Profile
Brochure
English

Certifcations Earthing Transformer Manufacturer

  • JDS-330/33 Earthing transformer Test

Frequently asked questions

Its loss characteristics are highly related to operating characteristics: ① No-load loss refers to the iron loss (core hysteresis and eddy current loss) during normal operation. Due to long-term no-load/light load status, it is the main operating loss; ② Load loss refers to the copper loss (winding resistance loss) during faults, which is only generated during short-time faults and accounts for a very low proportion. The impact on operating costs needs to be divided by scenarios: For low-voltage and medium-voltage distribution networks (earthing transformers operate for a long time), the impact of no-load loss is obvious, and models with low no-load loss (such as national standard level 1 energy efficiency) should be preferred during selection; for high-voltage/extra-high voltage systems (earthing transformers work for a short time during faults), the proportion of no-load loss is small, and fault tolerance performance can be prioritized. Overall, its annual loss is much lower than that of ordinary power transformers, and the operating cost is relatively low

Even though the optional auxiliary winding can deliver station‑service power under normal operating condition, its priority ranks below the main neutral‑earthing protection function.

During single‑phase earth‑fault event, large zero‑sequence currents flow through primary zig‑zag windings, which will induce considerable over‑voltage and over‑current on secondary side. Under fault condition, it is not allowed to keep critical station‑service loads running continuously via this auxiliary winding.

Project design should avoid relying entirely on the earthing‑transformer secondary winding for essential uninterruptible auxiliary power. Independent station‑service transformer or UPS power source shall be configured for important loads that cannot lose supply during earth‑fault incidents.

In general, parallel‑operation of multiple zig‑zag earthing transformers on one MV busbar is not recommended unless specially engineered. Each unit has its own manufacturing tolerance of zero‑sequence impedance. When paralleled, unbalanced zero‑sequence circulating currents will appear between transformers even without actual earth fault.

These circulating currents produce extra heating loss and may trigger mis‑operation of zero‑sequence protection relays. If project conditions really require parallel deployment, every unit’s zero‑sequence impedance tolerance, winding polarity and phase‑angle characteristics must be strictly matched, and detailed calculation on circulating‑current magnitude needs to be completed at design phase.

Most standard projects adopt one single earthing transformer for each isolated bus‑section as preferred solution.

Earthing transformer follows short‑time fault‑duty design philosophy, fundamentally different from conventional power transformer rated for continuous load. Its core design basis is short‑time neutral fault current together with fault clearing duration, rather than continuous power‑transfer capacity.

If users specify capacity according to continuous kVA of regular power transformer, the result will be either over‑sized with unnecessary high purchase cost and larger footprint, or wrong thermal design which cannot withstand required I²t fault energy during real single‑phase earth fault.

Proper specification work should start from system capacitive earth‑fault current, then derive required short‑time rating, instead of copying power‑transformer selection logic.

The IEC cooling code naming rule uses the first letter to identify the internal cooling medium. ONAN and ONAF start with “O”, which means mineral oil is the primary internal coolant and are the standard options for oil‑immersed units.

AN means air natural cooling and AF means air forced cooling, and these two codes are originally defined for dry‑type transformers without liquid insulation.

For oil‑immersed earthing transformers, AN and AF are not the primary design codes; they are only listed as alternative references for special compact cabinet‑integrated layouts where air convection dominates the thermal dissipation.

When placing an order, ONAN or ONAF should be selected as the formal cooling classification to avoid confusion in tender documents and grid approval files.

Know your supplier

Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m² Total staff: 700+ Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: Medium and High Voltage Switchgear/Power and Distribution Transformers/Instrument Transformers and Sensors/Lightning Protection and Electrical Insulation/Substations and E-Houses/Electrical Panel and Controlgear

Comments

Share your question or perspective
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.
Login
or continue with
New here?
Register