• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


1kW / 1.036 KWh portable power station

  • 1kW / 1.036 KWh portable power station
  • 1kW / 1.036 KWh portable power station

Key attributes

Brand Wone
Model NO. 1kW / 1.036 kWh portable power station
输出功率 1000W
Energy capacity 1036Wh
Series Portable power station

Product descriptions from the supplier

Description

Description:

This 1kW / 1.036 kWh portable power station can support up to 12 devices simultaneously, is easy to carry (11kg), and ideal for outdoor activities as well as emergency power supply for homes. This is a lifestyle change-maker and the dream device for adventurers.

Feature:

  • 3- Level Brightness.

  • SOS Function.

  • Equipped with 2 Wireless Charging Pads.

  • Capable to Charge 12 Devices Simultaneously.

  • Big Capacity in Small Box.

Basic parameters:

image.png

Electrical Parameters:

image.png

How are portable charging stations overcharged protected?

Voltage Detection:

  • Function: The Battery Management System (BMS) continuously monitors the voltage of each battery cell.

  • Principle: When the voltage of a battery cell reaches or approaches the preset upper limit (for example, the upper limit of a lithium-ion battery is usually 4.2V), the BMS will trigger overcharge protection.

Current Detection:

  • Function: The BMS monitors the charging current.

  • Principle: If the charging current exceeds the preset safety threshold, the BMS will reduce the charging current or completely cut off the charging circuit.

Temperature Detection:

  • Function: The BMS monitors the temperature of the battery.

  • Principle: If the battery temperature exceeds the preset safety threshold (for example, 60°C), the BMS will reduce the charging current or completely cut off the charging circuit to prevent dangers caused by overheating.

Logic Control:

  • Function: The BMS makes logical judgments based on the data of voltage, current, and temperature to decide whether to activate overcharge protection.

  • Principle: The microprocessor built into the BMS will judge whether the battery is in an overcharged state according to the preset algorithms and thresholds. If overcharge conditions are detected, the BMS will execute corresponding protection measures.

Protection Measures:

  • Cutting off the Charging Circuit: The BMS cuts off the charging circuit by controlling the charging relay or MOSFET (Metal Oxide Semiconductor Field Effect Transistor) to prevent the current from continuing to flow into the battery.Reducing the Charging Current: In some cases, the BMS may first reduce the charging current to observe the changes in the battery state. If the battery voltage still rises, then the charging circuit will be completely cut off.

  • Alarm Notification: The BMS can issue an alarm through the display screen or indicator light to remind the user that the battery has reached a full charge state and the charger needs to be disconnected.


Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 65666m²m² Total staff: 300+ Highest Annual Export(usD): 50000000
Workplace: 65666m²m²
Total staff: 300+
Highest Annual Export(usD): 50000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: Wire cable/High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/New energy/Tester/Integrated Electrical Equipment/Production equipment/Generator/Electrical fittings
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • What aspects does the inspection of industrial and commercial energy storage cover?
    As a frontline tester, I work with industrial and commercial energy storage systems daily. I know firsthand how critical their stable operation is for energy efficiency and business profitability. While installed capacity grows rapidly, equipment failures increasingly threaten ROI—over 57% of energy storage plants reported unplanned outages in 2023, with 80% stemming from equipment defects, system anomalies, or poor integration. Below, I share practical testing insights for the five co
    06/21/2025
  • Commercial and Industrial Energy Storage Systems
    I. Core Value Proposition✅ Energy Cost Optimization: Reduce electricity expenses by 30%-50% through peak-valley arbitrage (EU peak/off-peak spreads up to &euro;0.25/kWh) ✅ Power Reliability: Seamless backup power switching (<20ms response) for critical operations ✅ Renewables Integration: Increase solar self-consumption to >90%, minimizing curtailment losses ✅ Carbon Reduction: Achieve ~500 tons CO₂e annual reduction (1MW/2MWh system reference) II. Key Application Scenarios & Solut
    06/21/2025
  • AI-Enhanced Grid Frequency Regulation System Design for Commercial & Industrial Energy Storage Systems
    As renewable energy penetration rises in modern power systems and load variability grows increasingly complex, instability issues&mdash;especially frequency fluctuations&mdash;have become more prominent. Intelligent commercial and industrial energy storage systems address this challenge by leveraging AI to boost grid - frequency regulation efficiency and accuracy. They enable real - time frequency monitoring, millisecond - level charge/discharge responses, intelligent scheduling with con
    06/21/2025
  • What are the maintenance and fault prevention measures for industrial and commercial energy storage systems?
    As a front-line practitioner in commercial and industrial energy storage, I understand deeply that scientific prevention and maintenance strategies are crucial for long-term system stability. Here&rsquo;s my professional summary based on years of field experience:1. Core Strategies for Fault Prevention and MaintenanceBattery SystemIn daily operations, I've found precise parameter control essential. Maintain battery temperature at 25&plusmn;2℃, triggering alarms when deviating by &plu
    06/21/2025
  • What are the common faults that occur during the operation of equipment related to industrial and commercial energy storage?
    As an important part of the new power system, the stable operation of commercial and industrial energy storage systems is directly related to energy utilization efficiency and enterprise economic benefits. With the rapid growth of the installed capacity of commercial and industrial energy storage, equipment failure rate has become a key factor affecting investment returns. According to data from the China Electricity Council, in 2023, the proportion of unplanned outages of energy storage power s
    06/21/2025
  • Operational Analysis of Distributed Energy Storage Systems for Commercial & Industrial Behind-the-Meter Applications
    Energy storage technology, a focal point in new energy, stores electricity for grid peak/valley supply adjustment. Distributed energy storage in commercial/industrial contexts cuts costs via peak - shaving, boosts grid stability, and mitigates peak - valley imbalances. This paper explores its application for commercial/industrial users from scenarios and feasibility.1 Application Scenario Analysis1.1 Demand AnalysisElectricity costs dominate commercial/industrial energy expenses, especially for
    06/21/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.