Model
SFZ10-240000/230
SFZ10-180000/230
SFZ10-150000/230
SFZ10-120000/230
SFZ10-90000/230
SFZ10-63000/230
SFZ10-50000/230
SFZ10-40000/230
SFZ10-31500/230
SFZ10-240000/220
SFZ10-180000/220
SFZ10-150000/220
SFZ10-120000/220
SFZ10-90000/220
SFZ10-63000/220
SFZ10-50000/220
SFZ10-40000/220
SFZ10-31500/220
SFSZ10-240000/230
SFSZ10-180000/230
SFSZ10-150000/230
SFSZ10-1200000/230
SFSZ10-90000/230
SFSZ10-63000/230
SFSZ10-50000/230
SFSZ10-31500/230
SFSZ10-240000/230
SFSZ10-240000/220
SFSZ10-180000/220
SFSZ10-150000/220
SFSZ10-120000/220
SFSZ10-90000/220
SFSZ10-63000/220
SFSZ10-50000/220
SFSZ10-40000/220
SFSZ10-31500/220
SFS-240000/242
SFS-180000/242
SFS-150000/242
SFS-120000/242
SFS-90000/242
SFS-63000/242
SFS-50000/242
SFS-40000/242
SFS-31500/242
SFS-240000/230
SFS-180000/230
SFS-150000/230
SFS-120000/230
SFS-90000/230
SFS-63000/230
SFS-50000/230
SFS-40000/230
SFS-31500/230
SFS-240000/220
SFS-180000/220
SFS-150000/220
SFS-120000/220
SFS-90000/220
SFS-63000/220
SFS-50000/220
SFS-40000/220
SFS-31500/220
Basic info
Brand ROCKWILL
Model NO. 220kV Class oil-immersed transformer
Rated capacity 240000kVA
Primary voltage 220kV
Secondary voltage 6.3kV
Methods of regulation N/A
Winding type Three Winding
Series SF/SFS Series
Product Detail

Overview

Premium Durability: Superior insulation and mechanical resilience allow for extended system life and overall system reliability.reducing the frequency of outages. 

Certified Quality: Oil-immersed power transformers are manufactured, tested and delivered in our accordance with all applicable standards (ANSI, IEEE) maintaining US compliance which simplifies service and retrofitting.

Energy Efficient: Designed to accommodate heavier base loading for extended periods of time with low energy loss and minimal partial discharge for optimized energy savings.

 

Operating condition

1.working temperature:-30℃~40℃

2.Relative humidity: <90% (25℃) 

3.No corrosive gas, no obvious dirt, etc.

4.Altitude: <1000m

 

Applications:

The 220kV power transformers that are used in high-voltage transmission substations, large industrial facilities, and renewable energy projects to efficiently step up or step down power for long-distance distribution. They also support urban substations and critical infrastructure, ensuring stable electricity supply for national grid.

 

If you need to know about more parameters , Please check the model selection manual.

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Knowledges
What are the applications and trends of 35kV combined transformers?
What are the applications and trends of 35kV combined transformers?
Applications and Trends of 35kV Combined Instrument Transformers – From Echo’s PerspectiveHey everyone! My name is Echo, and I’ve been working in the field of instrument transformers for 12 years now. Today, I’d like to share some insights about the applications and future trends of 35kV combined instrument transformers. Hope this can give you a glimpse into this fascinating industry.Application Scenarios: More Than Just Metering ToolsFirst off, let's talk about applicati
Echo
07/21/2025
Development of Medium - Voltage Combined Electronic Transformers
Development of Medium - Voltage Combined Electronic Transformers
1 Measurement Principle of Combined Electronic Transformers1.1 Voltage Measurement PrincipleElectronic transformers measure voltage using the capacitive voltage division method. Since the voltage across a capacitor cannot change abruptly, the secondary voltage obtained directly through capacitive voltage division has poor transient response and low measurement accuracy. To improve the measurement accuracy, a precision sampling resistor is connected in parallel across the low-voltage capacitor. I
Dyson
07/21/2025
What are the fault diagnosis and handling technologies for 35kV combined transformers?
What are the fault diagnosis and handling technologies for 35kV combined transformers?
For fault diagnosis and handling of 35kV combined transformers, the following technical means can be adopted:Insulation Fault DiagnosisUse equipment such as high-voltage test transformers, power frequency withstand voltage testers, and partial discharge detection systems to conduct a comprehensive assessment of the insulation performance of combined transformers. When the insulation resistance is found to be lower than 1000MΩ or the dielectric loss factor tanδ exceeds 0.5%, an applic
Felix Spark
07/21/2025
What are the common overvoltages in the distribution network?
What are the common overvoltages in the distribution network?
Distribution networks, characterized by their wide distribution, large number of equipment, and low insulation level, are prone to insulation accidents caused by overvoltage. This not only reduces the stability of the entire distribution system and the insulation performance of the lines but also has a significant adverse impact on the safe operation of the power grid and the healthy and sustainable development of the power industry.From a circuit perspective, apart from the power source, the po
Leon
07/21/2025
Combined Voltage Transformer Secondary Circuit Overvoltage Suppression Technology
Combined Voltage Transformer Secondary Circuit Overvoltage Suppression Technology
This paper analyzes the above situation in - depth and summarizes technical measures to solve the problems.1. Main Problems of SPD Products in Voltage Transformer Secondary CircuitsCurrently, there are residual - current - free SPDs (switch - type lightning arresters) at home and abroad. Their main internal discharge circuits use discharge tubes/gaps, with high discharge current capacity (exceeding zinc oxide varistors). However, they have fatal flaws: poor voltage - limiting, arc - pulling volt
Dyson
07/21/2025
Analysis of Partial Discharge Principle (1)
Analysis of Partial Discharge Principle (1)
Analysis of Partial Discharge Principle (1)Under the action of an electric field, in an insulation system, discharge occurs only in some regions and does not penetrate between the conductors with the applied voltage. This phenomenon is called partial discharge. If partial discharge occurs near a conductor surrounded by gas, it can also be called corona.Partial discharge can occur not only at the edge of a conductor but also on the surface or inside an insulator. The discharge occurring on the su
Leon
07/19/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!