• Photovoltaic Auxiliary Energy Storage Transformer
Photovoltaic Auxiliary Energy Storage Transformer
discuss personally
Model
SGG-200kVA
Basic info
Brand ROCKWILL
Model NO. Photovoltaic Auxiliary Energy Storage Transformer
Rated frequency 50/60Hz
Rated capacity 200kVA
Series SGG
Product Detail

Product Overview:

The grid-connected energy storage auxiliary isolation transformer for photovoltaic power generation is generally used for solar inversion, with common voltages including 800V to 400V, 380V, 690V to 400V, 540V to 400V, etc. (customizable as required); due to the low photoelectric efficiency of photovoltaic silicon panels, the transformer is specially required to have high efficiency. The photovoltaic isolation transformer is equipped with a microcomputer intelligent time controller to set daytime operation and nighttime stop for reducing no-load power loss, a temperature controller to real-timely monitor the operating temperature of the transformer, control the start and stop of the cooling fan, and automatically stop and disconnect the transformer when the operating temperature is too high to reach the set critical temperature for protecting the safety of the transformer body, a self-reset overvoltage and undervoltage protector to prevent islanding operation, a surge protector to effectively prevent lightning damage to equipment and improve the safety factor of the power generation system, and a knife switch on the grid-connected side to facilitate effective operation and maintenance of the equipment.

Key Features:

  • Smart Controls: Microcomputer time controller reduces nighttime no-load losses.

  • Safety Protections:

  • Temperature monitor with auto-shutdown at critical thresholds.

  • Over/under-voltage self-reset protector prevents islanding.

  • Surge arrester for lightning protection.

  • Grid-side knife switch for maintenance.

  • Flexible Configurations: Available in single/multi-unit combinations (1:2, 1:3, etc.) for scalable PV systems.

Technical data:

Operating Conditions

  • Ambient Temperature: -15 to +50°C

  • Relative Humidity: 20 to 90% RH

  • Atmospheric Pressure: 860 to 1060 hPa

  • Storage/Transport Temperature: -20 to +55°C

  • Rated Capacity: 5-300KVA

  • Input Voltage: 800V

  • Input Current: As per actual capacity

  • Output Voltage: 400V

  • Output Current: As per actual capacity

  • Connection: Dyn11 (△/Y), Yny0 (Y/Y)

  • Efficiency: ≥96%

  • Frequency: 50Hz/60Hz

  • Insulation Impedance: ≤500MΩ at 25mA

  • Inductive Withstand Voltage: 125Hz/800V/60s

  • Insulation Class: Class H (155°C temperature resistance)

  • Noise Level: ≤30dB

  • Temperature Rise: ≤115K allowable

  • Impedance Voltage Drop: ≤4%

  • Cooling Structure: Forced air cooling with temperature controller (fan starts automatically at set temperature per customer requirements)

  • Protection Class: IP54

  • Anti-Interference Method: Copper foil isolation, shielded grounding

  • Waveform Distortion: No additional distortion

  • Electrical Strength: 3000V AC power frequency sine voltage for 1min without breakdown/flashover

  • Insulation Resistance (input/output to ground): Test voltage ≥1000VDC, insulation resistance >50MΩ

  • Overload Capacity: 2x rated current for 1min

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Ensuring Reliability: A Deep Dive into Transformer Maintenance
Ensuring Reliability: A Deep Dive into Transformer Maintenance
IntroductionElectric transformers are the backbone of modern power distribution systems, silently enabling the reliable delivery of electricity to homes, businesses, and industries. As these critical assets age and the demand for uninterrupted power grows, the importance of diligent transformer maintenance has never been greater. This essay explores the essential role of transformer maintenance, highlighting the value of proactive care, the impact of advanced diagnostic technologies, and the tra
Vziman
09/03/2025
How does a transformer work?
How does a transformer work?
Transformer Operation PrincipleA transformer is an electrical device that operates on the principle of electromagnetic induction to transfer electrical energy from one circuit to another. It enables the adjustment of voltage levels within an alternating current (AC) system, either stepping up (increasing) or stepping down (decreasing) voltage while maintaining the same frequency.Working Principle:Basic ComponentsA transformer consists of two coils, known as windings—the "primary winding" connect
Rockwell
09/03/2025
Constant testing of high-voltage cable lines
Constant testing of high-voltage cable lines
1. Definition of High-Voltage Cable Line Constant TestingHigh-voltage cable line constant testing refers to the systematic measurement, using specialized instruments, of electrical parameters such as resistance, inductance, capacitance, and conductance before a cable line is commissioned or after major maintenance. The aim is to obtain fundamental data characterizing the electromagnetic properties of the cable, serving as a critical testing phase that provides accurate parameter support for powe
Oliver Watts
09/03/2025
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
1.Work Environment Requirements and Safeguard MeasuresBased on technical requirements for cable equipment storage, laying, transportation, laying, transposition, testing, and cable terminations, the project owner and construction units have conducted extensive trials and implemented protective measures regarding ambient temperature, humidity, bending radius, traction control, and route optimization. These measures ensure high-voltage cable quality and on-site safety under harsh winter conditions
James
09/03/2025
Withstand voltage test of high-voltage cables
Withstand voltage test of high-voltage cables
Withstand voltage test is an insulation test, but it is a destructive test that can reveal insulation defects difficult to detect in non-destructive testing.The test cycle for high-voltage cables is three years, and it must be conducted after non-destructive tests. In other words, the withstand voltage test is performed only after all non-destructive tests have been passed.Most high-voltage cables used today are cross-linked polyethylene (XLPE) cables, which can have large cross-sections and cov
Oliver Watts
09/03/2025
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
I. Introduction to Cable Grounding Loop CurrentCables rated 110 kV and above use a single-core structure. The alternating magnetic field generated by the operating current induces a voltage on the metallic sheath. If the sheath forms a closed circuit through the earth, a grounding loop current will flow on the metallic sheath. Excessive grounding loop current (loop current exceeding 50 A, more than 20% of the load current, or a ratio of maximum-to-minimum phase current greater than 3) not only a
Felix Spark
09/03/2025
×