• Photovoltaic grid-connected isolation transformer
Photovoltaic grid-connected isolation transformer
discuss personally
Model
SGG-220kVA
SGG-180kVA
Basic info
Brand ROCKWILL
Model NO. Photovoltaic grid-connected isolation transformer
Rated frequency 50/60Hz
Rated capacity 220kVA
Series SGG
Product Detail

Product Overview:

Photovoltaic power generation inverter isolation transformers play a critical role in systems that harness solar energy via the photovoltaic effect at semiconductor interfaces, where solar cells serve as the core components. These cells are encapsulated and connected in series to form large-area modules, which, when integrated with power controllers, constitute a complete photovoltaic power generation device.

Designed primarily for solar inverter systems, photovoltaic transformers require high-efficiency performance to compensate for inherent energy conversion losses in photovoltaic setups. Their grid-side wiring configurations, such as Dyn11 and YD5 phase shift transformers with 120° phase displacement, ensure stable grid interconnection. To minimize no-load energy losses, these isolation transformers are typically operated during daylight hours and shut down at night.

Below are reference parameters for three-phase photovoltaic transformers:

Key Features:

  • Electrical Safety Isolation:Designed to achieve complete electrical separation between the photovoltaic system and the grid, preventing direct current (DC) leakage and reducing risks of electric shock. It blocks grid-borne harmonics and surges, ensuring clean power transmission.

  • Efficient Grid Compatibility:Supports standard grid connection configurations (e.g., Dyn11, YD5 with 120° phase shift) to match grid voltage and frequency requirements. Enables stable power inversion from DC (solar panels) to AC (grid), with conversion efficiency ≥98% to minimize energy loss.

  • Harmonic Suppression & Waveform Purity:Integrates low-loss core materials (e.g., oriented silicon steel) and foil winding technology to suppress 3rd harmonic distortion and maintain sine-wave output. Ensures compliance with grid power quality standards (e.g., IEEE 519) for reliable grid interconnection.

  • Adaptive Operation & Energy Savings:Features automatic daytime activation and nighttime shutdown to eliminate no-load losses. Suitable for off-grid/on-grid systems, with customizable capacity (5kVA–1000kVA) to match solar array scales.

  • Robust Environmental Adaptability:Constructed with weather-resistant enclosures (e.g., 304 stainless steel) for outdoor installations, resisting humidity, temperature fluctuations, and corrosion. Dry-type air cooling design ensures maintenance-free operation in harsh environments.

  • Customizable Design Flexibility:Supports voltage customization (input/output: 220V–1140V) and insulation classes (B/F/H) for diverse project needs. Compact structure fits limited space in solar power stations, with optional IP certifications for enhanced protection.

Technical data:

Conditions of Use. Working environment temperature: 15~+50℃

Operating ambient temperature:20—90%RH

Atmospheric pressure in the working environment:860 hpa---1060 hp2

Storage/transport temperature:20℃-- +55℃

Main technical features:

Rated capacity:5KVA—1000KVA

Input Voltage: Rated voltage 270V or 315V

Input current by actual voltage

Output voltage: Rated voltage: 380V or 400V

The output current is based on the actual voltage

Connection mode :dyn11

Efficiency :≤98.5%

Frequency: 50HZ/60HZ

Insulation resistance :25A less than 500MΩ

Induction withstand voltage :125HZ/800y/60

Insulation Chip Class :H (Temperature Resistance 180 °C)

Noise :≤30dB)

Temperature rise: ≤ allows for a temperature rise of 115k

Impedance Voltage Drop :≤4%

Structure: Forced air cooling, waiting for the temperature controller, according to customer requirements, reach a certain temperature, the fan will be automatically opened.

Degree of protection :IP00

Anti-interference mode: copper foil isolation shielding grounding:

Waveform Distortion No additional waveform distortion.

Electrical strength: Power frequency sinusoidal voltage 3000V, which lasts for one minute, without breakdown and flashover

Insulation resistance (input and output to ground) Test voltage at least 1000V DC insulation resistance greater than 1000MΩ

Overload capacity Twice the rated current for one minute.

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Ensuring Reliability: A Deep Dive into Transformer Maintenance
Ensuring Reliability: A Deep Dive into Transformer Maintenance
IntroductionElectric transformers are the backbone of modern power distribution systems, silently enabling the reliable delivery of electricity to homes, businesses, and industries. As these critical assets age and the demand for uninterrupted power grows, the importance of diligent transformer maintenance has never been greater. This essay explores the essential role of transformer maintenance, highlighting the value of proactive care, the impact of advanced diagnostic technologies, and the tra
Vziman
09/03/2025
How does a transformer work?
How does a transformer work?
Transformer Operation PrincipleA transformer is an electrical device that operates on the principle of electromagnetic induction to transfer electrical energy from one circuit to another. It enables the adjustment of voltage levels within an alternating current (AC) system, either stepping up (increasing) or stepping down (decreasing) voltage while maintaining the same frequency.Working Principle:Basic ComponentsA transformer consists of two coils, known as windings—the "primary winding" connect
Rockwell
09/03/2025
Constant testing of high-voltage cable lines
Constant testing of high-voltage cable lines
1. Definition of High-Voltage Cable Line Constant TestingHigh-voltage cable line constant testing refers to the systematic measurement, using specialized instruments, of electrical parameters such as resistance, inductance, capacitance, and conductance before a cable line is commissioned or after major maintenance. The aim is to obtain fundamental data characterizing the electromagnetic properties of the cable, serving as a critical testing phase that provides accurate parameter support for powe
Oliver Watts
09/03/2025
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
1.Work Environment Requirements and Safeguard MeasuresBased on technical requirements for cable equipment storage, laying, transportation, laying, transposition, testing, and cable terminations, the project owner and construction units have conducted extensive trials and implemented protective measures regarding ambient temperature, humidity, bending radius, traction control, and route optimization. These measures ensure high-voltage cable quality and on-site safety under harsh winter conditions
James
09/03/2025
Withstand voltage test of high-voltage cables
Withstand voltage test of high-voltage cables
Withstand voltage test is an insulation test, but it is a destructive test that can reveal insulation defects difficult to detect in non-destructive testing.The test cycle for high-voltage cables is three years, and it must be conducted after non-destructive tests. In other words, the withstand voltage test is performed only after all non-destructive tests have been passed.Most high-voltage cables used today are cross-linked polyethylene (XLPE) cables, which can have large cross-sections and cov
Oliver Watts
09/03/2025
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
I. Introduction to Cable Grounding Loop CurrentCables rated 110 kV and above use a single-core structure. The alternating magnetic field generated by the operating current induces a voltage on the metallic sheath. If the sheath forms a closed circuit through the earth, a grounding loop current will flow on the metallic sheath. Excessive grounding loop current (loop current exceeding 50 A, more than 20% of the load current, or a ratio of maximum-to-minimum phase current greater than 3) not only a
Felix Spark
09/03/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!