145kV/123kV Dead tank vacuum circuit breaker

  • 145kV/123kV Dead tank vacuum circuit breaker
  • 145kV/123kV Dead tank vacuum circuit breaker

Key attributes

Brand ROCKWILL
Model NO. 145kV/123kV Dead tank vacuum circuit breaker
Rated voltage 123/145kV
Rated normal current 4000A
Rated short circuit breaking current 40kA
Series RVD

Product descriptions from the supplier

Description

Product overview

As a new generation of distribution core equipment specially designed for 145kV three-phase AC systems, RVD vacuum high-voltage tank circuit breaker takes "SF6 free environmental protection technology+high-performance vacuum arc extinguishing+high stability operating mechanism" as its core, breaking the limitations of traditional tank circuit breakers. It can adapt to harsh high-voltage distribution scenarios and create long-term value for users from the perspectives of environmental protection, operation and maintenance, and safety. It is currently the preferred solution for upgrading high-voltage distribution systems in substations, industrial plants, and other areas.

Main Features

  • No SF6 gas design, green and zero burden: Abandoning traditional SF6 greenhouse gas insulation media, there are no harmful gas emissions throughout the process, in line with the dual carbon policy and environmental protection requirements, and there is no need to bear the environmental compliance costs and rectification risks of SF6 equipment.

  • High performance vacuum arc extinguishing chamber, long-term protection equipment: equipped with high-quality vacuum arc extinguishing components, the arc extinguishing response speed is fast, which can quickly cut off the arc, greatly reduce the erosion loss of conductive contacts, extend the life of equipment core components from the root, and reduce the frequency of maintenance and replacement.

  • High reliability operating mechanism, zero opening and closing errors: Customized and stable operating mechanism with high action accuracy and fast response speed, ensuring that each opening and closing operation is completed quickly and effectively, avoiding operational failures from the source, and ensuring the continuous operation of the distribution system.

  • Can type sealed structure, suitable for complex working conditions: adopting a fully sealed tank design, it has excellent dustproof, moisture-proof, and anti pollution performance, and can operate stably in complex outdoor/indoor environments such as high temperature, high humidity, and high dust.

  • Low operation and maintenance costs, high long-term cost-effectiveness: low loss rate of core components, low risk of failure, significantly reducing manpower and capital investment in spare parts replacement and on-site maintenance, and reducing long-term usage costs by more than 30% compared to traditional equipment.

  • Wide adaptation current range, strong scene compatibility: supports multiple rated current selections of 2000/3150/4000A, and can flexibly match high-voltage distribution systems of different capacities without the need for additional customization and adjustment.

product structure

The RVD vacuum high-voltage tank circuit breaker mainly consists of the following core components:
Vacuum arc extinguishing unit: Equipped with a high-performance vacuum arc extinguishing chamber, integrated with conductive contacts and insulating supports, it is the core module for achieving rapid arc extinguishing;

Sealed tank: It is sealed and packaged with high-strength metal material, with a vacuum insulated environment inside and an insulated sleeve (spiral structure in the picture) on the outside for external wiring;
Operating mechanism box: integrated stable operating mechanism, control components, and status display device, installed below the tank, responsible for receiving instructions and driving opening and closing actions;

Supporting frame: Using steel structure brackets with high-strength load-bearing performance, the equipment can be stably fixed to the installation foundation, while reserving space for operation and maintenance.

Technical Parameters

Specifications

Unit

Value

Rated voltage

kV

145

Rated current

A

2000/3150/4000

Rated short circuit breaking current

kA

31.5/40

Rated frequency

HZ

50/60

Operational altitude

M

≤2000

Operating ambient temperature

-45~50

Operating pollution class

Class

Wind speed resistance

m/s

34

Aseismatic class

Class

0.5G(AG5)

Rated short-time withstand current (r.m.s)

kA

40

Rated short-circuit withstand time

kA

3

1min rated power frequency withstand voltage (r.m.s)

Phase to earth

kV

275

Across isolating distance

kV

275(+40)

Phase to phase

kV

275

Rated lightning impulse withstand voltage (peak)

Phase to earth

kV

650

Across isolating distance

kV

650(+100)

Phase to phase

kV

650

Vacuum degree of arc extinguishing chamber

 

≤1.33x10⁻3

circuit-breaker class

Class

E2-C2-M2

Mechanical life

Times

10K

Opening time

ms

25正负5

Closing time

ms

45±10

Closing-Opening time

ms

≤60

Disconnector class

Class

M2

bus-transfer current/voltage switching by disconnector

A/V

1600/100

Application scenarios

  • 110kV/145kV substation: As the core switchgear of the main distribution circuit, it replaces traditional SF6 circuit breakers and adapts to the environmental upgrading and stable operation needs of the substation;

  • High voltage distribution system in large industrial plants: used for high-voltage incoming lines/distribution circuits in large enterprises such as steel and chemical industries, ensuring power supply stability in high load and continuous production scenarios;

  • New energy power station (wind/photovoltaic): adapted to the distribution system of wind and photovoltaic power stations, in line with the environmental protection requirements of green power projects, while withstanding the fluctuating load of new energy power generation;

  • Municipal infrastructure power distribution: used for high-voltage power distribution in urban rail transit and large data centers, meeting high safety and low fault operation standards.


Documentation Resource Library
Public.
RVD-145 Dead tank vacuum circuit breaker catalogue
Catalogue
English
Restricted
145kV(123kV)Dead tank vacuum circuit breaker drawing
Drawing
English
Consulting
Consulting
FAQ for
Q: What are the characteristics of high-voltage vacuum circuit breakers ?
A:
  1. Special Arc-Extinguishing Chamber: Needs larger volume (tens of mm electrode spacing), high-purity copper electrodes, and stricter vacuum (10⁻⁶~10⁻⁸Pa) to meet enhanced insulation/arc tolerance at high voltage. Optimized electrode shapes suppress arc diffusion.
  2. Breaking Capacity & Lifespan: Handles 25kA~63kA short-circuits via multi-break or magnetic arc tech. Mechanical lifespan reaches 5,000~10,000 cycles, suiting frequent operations (e.g., new energy grids).
  3. Reinforced Insulation: Internal insulation relies on high vacuum; external uses large-diameter ceramic/composite shells (≥25mm/kV creepage for 252kV) with extra skirts for high altitudes (>3000m).
  4. Eco & O&M Advantages: No SF₆, uses recyclable materials. O&M only needs checking mechanisms/shells, cycle 1~2 years, cost 30%~50% lower than SF₆ breakers.
Q: What is the difference between vacuum circuit breaker and SF6 circuit breaker?
A:
  1. Their core difference is arc-extinguishing media: Vacuum breakers use high vacuum (10⁻⁴~10⁻⁶Pa) for insulation and arc extinction; SF₆ breakers rely on SF₆ gas, which adsorbs electrons well to quench arcs.
  2. In voltage adaptation: Vacuum breakers fit medium-low voltages (10kV, 35kV; some up to 110kV), rarely 220kV+. SF₆ breakers suit high-ultra high voltages (110kV~1000kV), mainstream for ultra-high voltage grids.
  3. For performance: Vacuum breakers extinguish arcs fast (<10ms), have 63kA~125kA breaking capacity, suit frequent use (e.g., power distribution) with long life (>10,000 cycles). SF₆ breakers excel in stable large/inductive current breaking but work less frequently, needing insulation recovery time post-extinction.
  4. Compared to SF6 gas circuit breakers, vacuum circuit breakers can achieve zero greenhouse gas emissions and are more environmentally friendly because the arc extinguishing device does not contain any gas
Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • A Brief Discussion on the Issues of Converting Reclosers into Outdoor Vacuum Circuit Breakers for Use
    The rural power grid transformation plays an important role in reducing rural electricity tariffs and accelerating rural economic development. Recently, the author participated in the design of several small-scale rural power grid transformation projects or conventional substations. In rural power grid substations, conventional 10kV systems mostly adopt 10kV outdoor auto circuit vacuum reclosers.To save investment, we adopted a scheme in the transformation that removes the control unit of the 10
    12/12/2025
  • A Brief Analysis of Automatic Circuit Recloser in Distribution Feeder Automation
    An Automatic Circuit Recloser is a high-voltage switching device with built-in control (it inherently possesses fault current detection, operation sequence control, and execution functions without requiring additional relay protection or operating devices) and protective capabilities. It can automatically detect the current and voltage in its circuit, automatically interrupt fault currents according to inverse-time protection characteristics during faults, and perform multiple reclosures accordi
    12/12/2025
  • Recloser Controllers: Key to Smart Grid Reliability
    Lightning strikes, fallen tree branches, and even Mylar balloons are enough to interrupt current flow on power lines. That’s why utility companies prevent outages by equipping their overhead distribution systems with reliable recloser controllers.In any smart grid environment, recloser controllers play a critical role in detecting and interrupting transient faults. Although many short circuits on overhead lines can resolve themselves, reclosers help improve service continuity by automatically re
    12/11/2025
  • Application of Fault Diagnosis Technology for 15kV Outdoor Vacuum Automatic Circuit Reclosers
    According to statistics, the vast majority of faults on overhead power lines are transient, with permanent faults accounting for less than 10%. Currently, medium-voltage (MV) distribution networks commonly employ 15 kV outdoor vacuum automatic circuit reclosers in coordination with sectionalizers. This setup enables rapid restoration of power supply after transient faults and isolates faulty line segments in the event of permanent faults. Therefore, it is essential to monitor the operational sta
    12/11/2025
  • Application of 10kV Reclosers and Sectionalizers in Rural Distribution Networks
    1 Current Grid StatusWith the continuous deepening of rural power grid transformation, the health level of rural grid equipment is constantly improving, and power supply reliability basically meets user needs. However, regarding the current grid status, due to funding constraints, ring networks have not been implemented, dual power supplies are unavailable, and lines adopt a single radial tree-like power supply method. This resembles a tree trunk with many branches—meaning the lines have numerou
    12/11/2025
  • What’s the Difference Between a Recloser and a Pole-Mounted Breaker?
    Many people have asked me: “What’s the difference between a recloser and a pole-mounted circuit breaker?” It’s hard to explain in one sentence, so I’ve written this article to clarify. In fact, reclosers and pole-mounted circuit breakers serve very similar purposes—they are both used for control, protection, and monitoring on outdoor overhead distribution lines. However, there are significant differences in the details. Let’s examine them one by one.1.Different MarketsThis may be the biggest dis
    11/19/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.