Circuitus interruptor vacuus cum tank mortuo 145kV/123kV

  • 145kV/123kV Dead tank vacuum circuit breaker
  • 145kV/123kV Dead tank vacuum circuit breaker

Attributa principalia

Marca ROCKWILL
Numerus Modeli Circuitus interruptor vacuus cum tank mortuo 145kV/123kV
Votum nominatum 123/145kV
currus electricus nominatus 4000A
currentis rumpendi nominale in circuitu commutato 40kA
Series RVD

Descriptiones productorum a fornitori

Descriptio

Product overview

Ut nova generatio distributionis core aequipmenti specialiter designata pro systematis 145kV triphasico AC, RVD vacuum high-voltage tank circuit breaker "SF6 free environmental protection technology+high-performance vacuum arc extinguishing+high stability operating mechanism" sibi adhibet, limites traditionum circuitorum interrumperentium frangens. Id potest adaptari ad dura scenaria distributionis altae tensionis et valorem longum temporis creare utentibus ex perspectivis protectionis ambientalis, operationis et manutentionis, et securitatis. Nunc est electus solutio pro melioratione systematum distributionis altae tensionis in substationibus, plantis industrialibus, et aliis locis.

Main Features

  • Design sine SF6 gas, viridis et nullus onus: relictis traditionibus SF6 gas insulantis, non sunt emissiones gasium noxiorum per totum processum, secundum politicam bini carbonis et requisitos protectionis ambientalis, nec est necessarium portare costus compliance ambientalis et pericula rectificationis aequipmenti SF6.

  • Camera arc extinguishing vacui altae performance, protectio longa temporis aequipmenti: instructa cum componentibus arc extinguishing vacui optimi, celeritas responsus arc extinguishing est velox, quae potest cito arcum dirumpere, magnoque in minus redigere consumptionem contactuum conductivorum, a radice vitam partium core aequipmenti extollere, et frequentiam manutentionis et replacementis minuere.

  • Mechanismus operationis altae fidei, nulla erroris apertionis et clausurae: Mechanismus operationis customizatus et stabilis, cum exactitudine actionis alta et celeritate responsus, quod certificat ut omnis operatio apertionis et clausurae cito et efficaciter absolvatur, evitans errores operationis ab origine, et continuitatem operationis systematis distributionis garantens.

  • Structura sigillata can type, apta pro conditionibus laboris complexis: adoptante designum tank sigillatum penitus, habet excellentem performantiam contra pulvis, humiditatem, et pollutionem, et potest operari stabiliter in ambientes outdoor/indoor complexos sicut alta temperatura, alta humiditas, et alta pulvis.

  • Costus operationis et manutentionis bassi, altus ratio costus longi temporis: rata bassa perdendorum partium core, periculum parvum deficiendi, significanter reducens investitionem manu et capitali in replacementem partium spare et manutentionem in situ, et reducens costus usus longi temporis plus quam 30% comparato cum aequipmento traditionali.

  • Latus ambitus currentis, fortis compatibilitas scena: supportat multas selectiones currentis nominati 2000/3150/4000A, et potest flexibiliter congruere cum systematibus distributionis altae tensionis diversarum capacitatum sine necessitate customizationis et adjustmentis additionis.

product structure

RVD vacuum high-voltage tank circuit breaker principiter constat ex sequentibus partibus core:
Vacuum arc extinguishing unit: Instructa cum camera arc extinguishing vacui altae performance, integrata cum contactibus conductivis et sustentationibus insulantibus, est modulum core ad effectum arc extinguishing celerem;

Tank sigillatus: Sigillatus et packagatus cum materia metallica altae firmitudinis, cum ambiente insulantium vacui intra et tuba insulanti (structura spiralis in pictura) extra pro connectionibus externis;
Box mechanismi operationis: integrat stable mechanismus operationis, componentes controlis, et dispositivum display status, installatum infra tank, responsabile pro receptione instructionum et motu apertionis et clausurae;

Supporting frame: Usurans brachia structurae ferreae altae firmitudinis onus ferendae, aequipmentum potest stabiliter fixari ad fundamentum installationis, dum spatium reservat pro operatione et manutentione.

Technical Parameters

Specifications

Unit

Value

Rated voltage

kV

145

Rated current

A

2000/3150/4000

Rated short circuit breaking current

kA

31.5/40

Rated frequency

HZ

50/60

Operational altitude

M

≤2000

Operating ambient temperature

-45~50

Operating pollution class

Class

Wind speed resistance

m/s

34

Aseismatic class

Class

0.5G(AG5)

Rated short-time withstand current (r.m.s)

kA

40

Rated short-circuit withstand time

kA

3

1min rated power frequency withstand voltage (r.m.s)

Phase to earth

kV

275

Across isolating distance

kV

275(+40)

Phase to phase

kV

275

Rated lightning impulse withstand voltage (peak)

Phase to earth

kV

650

Across isolating distance

kV

650(+100)

Phase to phase

kV

650

Vacuum degree of arc extinguishing chamber

 

≤1.33x10⁻3

circuit-breaker class

Class

E2-C2-M2

Mechanical life

Times

10K

Opening time

ms

25正负5

Closing time

ms

45±10

Closing-Opening time

ms

≤60

Disconnector class

Class

M2

bus-transfer current/voltage switching by disconnector

A/V

1600/100

Scenarii applicationis

  • Substatio 110kV/145kV: Ut apparatum commutationis principalem circuiti distributionis, id loco circuitorum interrumperendorum SF6 traditorum substituit et ad exigentias renovationis ambientalis ac stabilitatis operationis substations accommodatur;

  • Sistema distributionis altae tensionis in magnis plantis industrialibus: pro lineis incoming/distributionis altae tensionis in magnis corporibus sicut siderurgia et industria chimica, securitatem supplytionis electricae in scenariis altae oneris et productionis continua garantit;

  • Statio potestatis novae (ventus/photovoltaicus): ad systema distributionis stationum venti et photovoltaicarum adaptatur, cum requisitis protectionis ambientalis projectorum viridis potestatis congruens, simulque fluctuantem onus generationis potestatis novae tolerans;

  • Distributio potestatis infrastructurae municipalis: pro distributione altae tensionis in transitu rail urbano et magnis centris datarum, standarda altioris securitatis et minoris operationis defectivae complens.


Bibliotheca Documentorum Rerum
Restricted
RVD-145 Dead tank vacuum circuit breaker catalogue
Catalogue
English
Consulting
Consulting
Restricted
145kV(123kV)Dead tank vacuum circuit breaker drawing
Drawing
English
Consulting
Consulting
FAQ
Q: Quae sunt characteristicae circuitorum interrumpendorum vacui alti voltaginis?
A:
  1. Special Arc-Extinguishing Chamber: Indiget maius volumen (inter spatia electrodum decem ad centenas millimetros), electrodos cuprei purissimi, et vacuum strictius (10⁻⁶~10⁻⁸Pa) ut insulatio/arcus tolerentia sub alto voltage satisfaciantur. Formae electrodorum optimatae arcum diffundere prohibent.
  2. Breaking Capacity & Lifespan: Tractat 25kA~63kA circuitus brevis per technologiam multi-break vel magneticam arcus. Vitae mechanicae durant 5,000~10,000 cyclis, apta operationibus frequentibus (sicut in reticulis novae energiae).
  3. Reinforced Insulation: Insulatio interna dependet a vacuo alto; externa utitur testis ceramicis/compositis magni diametri (≥25mm/kV creepage pro 252kV) cum ulnis additis pro altitudinibus altis (>3000m).
  4. Eco & O&M Advantages: Nullum SF₆, utitur materialibus recyclabilibus. O&M tantum mechanismos/testas inspicere indiget, cyclus 1~2 annos, costum 30%~50% minus quam interruptores SF₆.
Q: Quid est differentia inter circuitum interruptorem vacui et circuitum interruptorem SF
A:
  1. Diversitas eorum principalis est in medio arcus extinguendi: interruptores vacui utuntur alto vacuo (10⁻⁴~10⁻⁶Pa) ad insulationem et extinctionem arcus; interruptores SF₆ confidunt in gas SF₆, quod electrona bene adsorbet ad extinguendum arcum.
  2. In adaptatione voltus: interruptores vacui conveniunt ad media et parva voltage (10kV, 35kV; nonnulli usque ad 110kV), raro supra 220kV. Interruptores SF₆ apti sunt ad altas et ultra-altas voltus (110kV~1000kV), praecipue in rete ultra-alti voltaginis.
  3. De performance: interruptores vacui celeriter arcus extinguunt (<10ms), habent capacitatem interrumpendi 63kA~125kA, et conveniunt ad frequentem usum (sicut in distributione electricitatis) cum longa vita (>10,000 cyclus). Interruptores SF₆ excellunt in stabiliter magnas et inductivas currentes interrumpendo, sed minus frequenter operantur, post extinctionem requirunt tempus ad restitutionem insulationis.
Cognosce tui fornitori
Venditio Online
Ratio praestabilitae tradendae
Tempus responsionis
100.0%
≤4h
Brevis Descriptio Societatis
Locus Operis: 108000m²m² Numerus omnium laborantium: 700+ Summa Annua Exportatio (USD): 150000000
Locus Operis: 108000m²m²
Numerus omnium laborantium: 700+
Summa Annua Exportatio (USD): 150000000
Servitia
Genus Negotii: Design/Fabricatio/Venditio
Categorias Principales: apparatus electrum altum voltus/transformator
Gubernatio vitae
Servitia gestionis curae integralis pro quaestu, usu, conservatione et post-venditionem apparatus electricorum, securitatem operationis, continuationem imperii et usum electricitatis sine cura garantia.
Fornitori instrumentorum praeteritus est certificationem qualificationis platformae et iudicium technicum, ut ex fonte conformitas, professionalitas et fiducia servantur.

Producta Connexa

Cognitio Connexa

  • HECI GCB for Generators – Cepus SF₆ Circuit Breaker
    1. Definitio et Functio1.1 Munus Interruptoris Circuiti GeneratorisInterruptor Circuitus Generatoris (GCB) est punctum disiunctionis controllabile situatum inter generator et transformator incrementalis, servans ut interficium inter generator et rete electricitatis. Principales eius functiones includunt isolationem defectuum lateris generatoris et facilitationem controlis operationis durante synchronizatione generatoris et connectione ad rete. Principium operativum GCB non differt significanter
    01/06/2026
  • Apparatus Distributionis Transformatorisque Experimentatio Inspectio et Conservatio
    1. Manutentio et Inspectio Transformatoris Aperi interruptorem circuitus bassae tensionis (LV) transformatoris in manu, remove fusum alimenti controlis, et pende signum “Noli Claudere” super manubrium commutationis. Aperi interruptorem circuitus altae tensionis (HV) transformatoris in manu, claudi commutatorem terrae, exsolvare totaliter transformatorem, claude armarium interruptoris HV, et pende signum “Noli Claudere” super manubrium commutationis. Pro manutentione transformatoris sicci: primo
    12/25/2025
  • Quomodo Resistentiam Isolationis Transformatorum Distributionis Probes
    In operibus practicis, resistentia insulationis transformatorum distributionis saepe bis metitur: resistentiam inter spiram alti voltaginis (HV) et spiram bassi voltaginis (LV) plus vasum transformatoris, et resistentiam inter spiram LV et spiram HV plus vasum transformatoris.Si ambae mensurationes valores acceptabiles praebent, indicat quod insulatio inter spiram HV, spiram LV, et vasum transformatoris est probata. Si una mensuratio deficiat, testes pairwise resistentiae insulationis inter omne
    12/25/2025
  • Principia Design pro Transformeribus Distributionis in Columna Fixis
    Principia Design Pro Distributionibus Transformerum in Polum Fixis(1) Principia Locorum et DispositionumPlataformae transformerum in polum fixarum debent collocari iuxta centrum oneris aut prope onera critica, secundum principium “parva capacitas, plura loca” ad facilitatem substitutionis et maintenance. Ad distributionem electricitatis domesticam, transformatores triphasici possunt instaurari iuxta necessitatem praesentem et projectiones futurorum incrementorum.(2) Selectio Capacitatis pro Tran
    12/25/2025
  • Solutio Controlis Stridoris Transformatorum pro Diversis Installationibus
    1. Mitigatio sonoris pro camera transformatoris independente in superficie terraeStrategia mitigationis:Primum, fac inspectionem et maintenance cum potestate interrupta, includens renovationem olei insulantis vetustatis, examinationem et consolidationem omnium fixorum, et mundationem pulvis a unitate.Deinde, reficere fundamentum transformatoris vel installare dispositiva isolationis vibrationis—ut gommae vel isolatores springalis—selecta secundum gravitatem vibrationis.Tandem, fortificare insula
    12/25/2025
  • Identificatio Risorum et Mensorum Controli pro Operibus Substitutionis Transformatoris Distributionis
    1. Praeventio et Controulus Periculi Fulgoris ElectriciIuxta standards designi typici pro renovationibus rete distributionis, distantia inter fusibile cadens transformatoris et terminale alta tensio est 1.5 metri. Si grua ad substitutionem utitur, saepe impossibile est retinere praescriptam minimum clearance securitatis 2 metri inter brachium gruae, apparatus levandi, funes, funes filiferae, et partes vivae 10 kV, quod periculum grave fulgoris electrici praebet.Mensurae Controuli:Mensura 1:Exsti
    12/25/2025

Solutiones Relatae

  • Design Solution of 24kV Siccum Aera Insulatum Ring Main Unit
    Combinatio Solidi Insulationis Adiuvantis + Insulationis Aereae Siccae repraesentat directionem pro RMU 24kV. Per requirementa insulationis cum compactitate equilibrata et adiuvante solidum insulationis, testes insulationis sine magnificatione significativa dimensionum inter phasos et inter phasos et terram transigi possunt. Inclusio columnae pole solidificat insulationem pro interruptore vacuo et conductoribus eius coniunctis.Maintinendo spatium phasorum exiens 24kV ad 110mm, intensitas electri
    08/16/2025
  • Optimizatio Design Schematum pro Unitate Circulorum Principalium Aere Insulata 12kV ad Minuendam Probabilitatem Disruptionis Emissionis
    Cum celeri progressus industriae electricitatis, conceptus ecologicus de carbonis minore, energiae servanda, et conservatione ambientis profundissime integratus est in designum et fabricam productorum electricorum pro distributione et generatione electricitatis. Unitas Distributiva Circuli (RMU) est dispositivum electricum clavem in retibus distributionis. Securitas, conservatio ambientis, fides operativa, efficacia energetica, et oeconomia sunt tendentiae inevitabiles in eius progressu. RMUs tr
    08/16/2025
  • Analyse communium problematum in unitatibus principali circuitu isolatis gas 10kV (RMUs)
    Introductio:​​RMUs insulati gaseis 10kV sunt amplissime usitati propter multas suas utilitates, sicut quod sint perfecte clausi, habeant excellentem insulativam qualitatem, non requirant maintenance, sint compacti, et praebent installationem flexibilem et commodam. In hoc stadio, paulatim facti sunt nodus criticus in rete distributionis urbano anulari et iocabuntur partem significativam in systemate distributionis electricitatis. Difficultates in RMUs insulatis gaseis possunt graviter impingere
    08/16/2025
Non invenisti adhuc opportunos fornitoris ut te inveniant Citationem Nunc Accipe
Non invenisti adhuc opportunos fornitoris ut te inveniant
Citationem Nunc Accipe
Inquiry
Descarica
Obtine Applicatio Commerciale IEE-Business
Utiliza app IEE-Business ad inveniendum apparatus obtinendumque solutiones coniungendum cum peritis et participandum in collaboratione industriale ubique et semper propter totam supportionem tuorum projectorum electricitatis et negotiorum