• 10kV Short-Circuit Current Limiter
10kV Short-Circuit Current Limiter
discuss personally
Model
DDX1-12/630
Basic info
Brand RW Energy
Model NO. 10kV Short-Circuit Current Limiter
Rated voltage 12kV
Rated normal current 630A
Rated frequency 50/60Hz
Series DDX
Product Detail

Product Introduction

The DDX1 Short-Circuit Current Limiter (abbreviated as: Current Limiter) is a high-speed switch with short-circuit current breaking capability. It can completely interrupt the short-circuit current within 10ms after a short-circuit fault occurs, before the instantaneous value of the short-circuit current rises to the expected peak.It integrates fast cutting technology, high-voltage current limiting technology, electronic measurement and control technology, and high-voltage insulation technology. This integration enables rapid current limiting and breaking of short-circuit currents in power generation, distribution, and consumption systems, preventing key power equipment such as generators and transformers from being impacted by catastrophic short-circuit currents.At the same time, it can also optimize the operation mode of the distribution system, achieving the effects of energy conservation and consumption reduction, improving power quality, and enhancing power supply reliability.

Product Features and Benefits

  • Strong short-circuit breaking ability (large capacity): rated breaking short-circuit current 50kA~200kA.

  • Fast breaking speed (high speed): full breaking time less than 10ms.

  • The breaking process has obvious current limiting characteristics (current limiting).

  • The action criterion adopts the instantaneous value of current and the instantaneous value of current change rate.

  • The current sensor is integrated with the fast isolator, and the structure is simplified.

  • The electronic controller works independently in three phases through high temperature and strong interference tests to ensure the overall reliability of the product.

Electrical parameters

serial number

Parameter Name

unit

Technical parameters

1

Rated voltage

kV

12

2

Rated current

A

630-6300

3

Rated expected short-circuit breaking current

kA

50-200

4

Current limit coefficient = cut-off current / expected short-circuit current peak

%

15~50

5

Insulation level

Power frequency withstand pressure

kV/1min

42

Lightning impact withstand pressure

kV

75

Product Usage

  • Bypass current limiting reactor (energy saving and consumption reduction, eliminating reactor reactive power, and improving power supply quality).

  • Parallel operation of segmented buses in large-capacity power distribution system (optimizing load distribution and reducing network impedance).

  • Short-circuit protection at generator outlet or low voltage side of transformer.

  •  Short-circuit protection for power plant branch buses and plant high variations.

 

Know your supplier
RW Energy
Zhejiang Rockwell Energy Technology Co., Ltd. is an international enterprise specializing in the research, development and manufacturing of recloser controllers, power quality management, power monitoring systems and other high-end power equipment. In today's critical period of global energy transition and power system upgrading, the company has gathered a group of top talents in the fields of power engineering, automation control, software development, etc., who carry the enthusiasm and persistence for the power business, and are committed to overcoming the complex problems in the power system, and promoting the intelligent development of the power industry with innovative technology. Mission: To make global electricity smarter, more reliable and more efficient with innovative technology. Vision: To be the leader in global power intelligence.
Main Categories
High Voltage Electrical Apparatus/New energy/Tester
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$100000000
Professional Experience
12 years
Workplace
30000m²
占位
占位
Related Products
Related Knowledges
What is the difference between a dielectric and an insulator?
What is the difference between a dielectric and an insulator?
Dielectrics and insulators are distinguished primarily by their applications. One of the main differences is that a dielectric can store electrical energy by becoming polarized in an electric field, whereas an insulator resists the flow of electrons to prevent current conduction. Other key differences between them are outlined in the comparison chart below.Definition of DielectricA dielectric material is a type of insulator that contains few or no free electrons. When subjected to an electric fi
Edwiin
08/30/2025
Fault Analysis and Treatment of Oil-Immersed Transformers
Fault Analysis and Treatment of Oil-Immersed Transformers
Oil Leakage at Welded JointsOil leakage at welded joints primarily stems from poor welding quality, such as incomplete or detached welds, and defects like pinholes and gas pores. Although oil-immersed transformers are initially coated with solder and paint during manufacturing, potentially masking these issues temporarily, the defects tend to surface during operation. Additionally, electromagnetic vibration can cause weld cracks, leading to oil leakage.To resolve such leaks, the first critical s
Edwiin
08/29/2025
What losses occur during operation of the transformer? How to reduce losses?
What losses occur during operation of the transformer? How to reduce losses?
Transformers experience various types of losses during operation, primarily categorized into two main types: copper losses and iron losses.Copper LossesCopper losses, also known as I²R losses, are caused by the electrical resistance of the transformer windings—typically made of copper. As current flows through the windings, energy is dissipated in the form of heat. These losses are proportional to the square of the load current (I²R), meaning they increase significantly with high
Rockwell
08/29/2025
Cable Fault Detection, Testing, Location and Repair
Cable Fault Detection, Testing, Location and Repair
I. Methods for Cable Testing and Inspection:Insulation Resistance Test: Use an insulation resistance tester to measure the insulation resistance value of the cable. A high insulation resistance value indicates good insulation, while a low value may suggest insulation problems requiring further investigation.Voltage Withstand Test: Apply a high-voltage test using a high-voltage tester to verify whether the cable can withstand high voltage under its rated operating conditions. Under normal circums
Leon
08/29/2025
Cable Quality Inspection and Cable Detection & Testing
Cable Quality Inspection and Cable Detection & Testing
Power cable quality inspection and cable testing are conducted to ensure that the cable's quality and performance meet specified requirements, thereby guaranteeing the safe and stable operation of power systems. Below are some common contents of power cable quality inspection and cable testing:Visual Inspection: Check the cable surface for physical defects such as damage, deformation, or scratches to ensure the cable's exterior is intact.Dimensional Measurement: Measure dimensional parameters su
Edwiin
08/29/2025
Transformer Detection, Testing, Maintenance and Servicing
Transformer Detection, Testing, Maintenance and Servicing
Transformer testing, inspection, and maintenance are essential tasks to ensure normal operation and extend the service life of transformers. Below are some recommended steps:Visual Inspection: Regularly inspect the transformer's exterior, including the enclosure, cooling system, and oil tank. Ensure the enclosure is intact, free from corrosion, damage, or leakage.Insulation Resistance Testing: Use an insulation resistance tester to check the transformer's insulation system. Verify that the insul
Vziman
08/29/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!