Dielectric Properties of Insulating Materials (Formula & Constant)

Electrical4u
Electrical4u
Field: Basic Electrical
0
China

What Are The Dielectric Properties Of Insulating Materials

We can first go through the description of dielectric materials. It actually does not conduct electricity. They are insulators having very low electrical conductivity. So we have to know the difference between dielectric material and insulating material. The difference is that insulators block the flow of current but the dielectrics accumulate electrical energy. In capacitors, it performs as electrical insulators.
dielectric properties of insulationNext, we can come to the topic. The dielectric properties of insulation include breakdown voltage or dielectric strength, dielectric parameters like permittivity, conductivity, loss angle and power factor. The other properties include electrical, thermal, mechanical and chemical parameters. We can discuss the main properties in detail below.

Dielectric Strength or Breakdown Voltage

The dielectric material has only some electrons in normal operating condition. When the electric strength is increased beyond a particular value, it results in breakdown. That is, the insulating properties are damaged and it finally becomes a conductor. The electrical field strength at the time of breakdown is called breakdown voltage or dielectric strength. It can be expressed in minimum electrical stress that will result in breakdown of the material under some condition.

It can be reduced by ageing, high temperature and moisture. It is given as
Dielectric strength or Breakdown voltage =
V→ Breakdown Potential.
t→ Thickness of the dielectric material.
Relative permittivity
It is also called as specific inductive capacity or dielectric constant. This gives us the information about the
capacitance of the capacitor when the dielectric is used. It is denoted as εr. The capacitance of the capacitor is related with separation of plates or we can say the thickness of dielectrics, cross sectional area of the plates and the character of dielectric material used. A dielectric material having high dielectric constant is favoured for capacitor.
Relative permeability or dielectric constant =

We can see that if we substitute air with any dielectric medium, the capacitance (capacitor) will get improved. The dielectric constant and dielectric strength of some dielectric materials are given below.

Dielectric material

Dielectric Strength(kV/mm)

Dielectric Constant

Air

3

1

Oil

5-20

2-5

Mica

60-230

5-9

Table no.1

Dissipation Factor, Loss Angle and Power Factor

When a dielectric material is given an AC supply, no power utilization takes place. It is perfectly achieved only by vacuum and purified gases. Here, we can see that the charging current will head the voltage applied by 90o which is shown in figure 2A. This implies there is no loss in power in insulators. But most of the cases, there is a dissipation of energy in the insulators when alternating current is applied. This loss is known as dielectric loss. In practical insulators, the leakage current will never lead the voltage applied by 90o (figure 2B). The angle formed by the leakage current is the phase angle (φ). It will be always less than 90. We will also get the loss angle (δ) from this as 90- φ.
dielectric properties of insulationThe equivalent circuit with capacitance and resistor in collateral (parallel) are represented below.
dielectric properties of insulationFrom this, we will get the dielectric power loss asX → Capacitive reactance (1/2πfC)
cosφ → sinδ
In most cases, δ is small. So we can take sinδ = tanδ.
So, tanδ is known as power factor of dielectrics.
The importance of the knowledge of the properties of dielectric material is in the scheming, manufacturing, functioning and recycling of the dielectric (insulating) materials and it can be determined by calculation and measurement.

Statement: Respect the original, good articles worth sharing, if there is infringement please contact delete.

Give a tip and encourage the author!
Recommended
THD Measurement Error Standards for Power Systems
THD Measurement Error Standards for Power Systems
Error Tolerance of Total Harmonic Distortion (THD): A Comprehensive Analysis Based on Application Scenarios, Equipment Accuracy, and Industry StandardsThe acceptable error range for Total Harmonic Distortion (THD) must be evaluated based on specific application contexts, measurement equipment accuracy, and applicable industry standards. Below is a detailed analysis of key performance indicators in power systems, industrial equipment, and general measurement applications.1. Harmonic Error Standar
Edwiin
11/03/2025
Busbar-Side Grounding for 24kV Eco-Friendly RMUs: Why & How
Busbar-Side Grounding for 24kV Eco-Friendly RMUs: Why & How
Solid insulation assistance combined with dry air insulation is a development direction for 24 kV ring main units. By balancing insulation performance and compactness, the use of solid auxiliary insulation allows passing insulation tests without significantly increasing phase-to-phase or phase-to-ground dimensions. Encapsulation of the pole can address the insulation of the vacuum interrupter and its connected conductors.For the 24 kV outgoing busbar, with the phase spacing maintained at 110 mm,
Dyson
11/03/2025
How Vacuum Tech Replaces SF6 in Modern Ring Main Units
How Vacuum Tech Replaces SF6 in Modern Ring Main Units
Ring main units (RMUs) are used in secondary power distribution, directly connecting to end-users such as residential communities, construction sites, commercial buildings, highways, etc.In a residential substation, the RMU introduces 12 kV medium voltage, which is then stepped down to 380 V low voltage through transformers. The low-voltage switchgear distributes electrical energy to various user units. For a 1250 kVA distribution transformer in a residential community, the medium-voltage ring m
James
11/03/2025
What Is THD? How It Affects Power Quality & Equipment
What Is THD? How It Affects Power Quality & Equipment
In the field of electrical engineering, the stability and reliability of power systems are of paramount importance. With the advancement of power electronics technology, the widespread use of nonlinear loads has led to an increasingly serious problem of harmonic distortion in power systems.Definition of THDTotal Harmonic Distortion (THD) is defined as the ratio of the root mean square (RMS) value of all harmonic components to the RMS value of the fundamental component in a periodic signal. It is
Encyclopedia
11/01/2025
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.