What is Oil Immersed Electrical Equipment?

Encyclopedia
Field: Encyclopedia
0
China

What is Oil Immersed Electrical Equipment?

Transformer Oil Sampling Definition

Transformer oil sampling is defined as the process of collecting a sample of oil from a transformer or other oil-immersed electrical equipment for analysis.

e9f33124d27537989aa55cf16183ae8a.jpeg

Importance of Oil Sampling

Regular oil sampling helps detect potential problems, ensuring the reliability and efficiency of transformers.

Sampling Frequency

The frequency of transformer oil sampling depends on several factors, such as:

  • The type and size of the transformer

  • The age and condition of the oil

  • The operating environment and load

  • The manufacturer’s recommendations

  • The industry standards and regulations

Safety Precautions

  • Wear personal protective equipment (PPE), such as gloves, goggles, and fire-resistant clothing.

  • Use proper tools and equipment that are suitable for high-voltage applications.

  • Avoid sampling in adverse weather conditions, such as rain, snow, fog, dust, or high humidity.

  • Keep away from sources of ignition or heat near the transformer or oil.

  • Dispose of waste oil and materials properly according to environmental regulations.

Benefits of Transformer Oil Sampling

  • It helps extend the life span and efficiency of the transformer by detecting and preventing potential problems before they become serious or irreversible.

  • It helps reduce maintenance costs and downtime by optimizing maintenance schedules and interventions based on actual oil conditions rather than fixed intervals.

  • It helps improve safety and reliability by reducing the risk of failures or faults.

Methods of Oil Testing

  • Visual analysis

  • Dielectric breakdown voltage (BDV) test

  • Color analysis

  • Dissolved gas analysis (DGA) test

  • Flashpoint or fire point test

  • Dissolved metals test

  • Furanic compound test

Give a tip and encourage the author!
Recommended
Strange Devices on Transmission Lines: 5 Little-Known Practical Functions(1)
1 Aviation Warning SpheresAviation warning spheres, also known as reflective safety spheres, are used on overhead transmission lines near airports, especially on extra-high-voltage (above 220kV) lines and river-crossing transmission lines. Highly visible aviation marker spheres (aviation warning spheres) must be installed along the lines to provide warning signals.The aviation marker sphere (aviation warning sphere) has a diameter of ф=600mm. The sphere can be manufactured in various bright colo
Leon
09/04/2025
Transmission Line
In transmission lines, a "π" connection involves breaking the original line from Substation A to Substation B and inserting Substation C, forming a "π" configuration. After the "π" connection, the original single line is divided into two independent transmission lines. Following the "π" connection, Substations B and C may both be powered by Substation A (in this case, Substation C receives power via a feeder from Substation B's busbar, or possibly from another voltage point within Substation B);
Encyclopedia
09/04/2025
What are the principles of forced re-energization of transmission lines?
Principles of Forced Re-energization of Transmission LinesRegulations for Forced Re-energization of Transmission Lines Correctly select the forced re-energization end of the line. If necessary, change the connection configuration before forced re-energization, taking into account the reduction of short-circuit capacity and its impact on grid stability. There must be a transformer with its neutral point directly grounded on the busbar at the forced re-energization end. Pay attention to the impact
Edwiin
09/04/2025
Analysis of Accident Handling in Transmission Lines
Analysis of Transmission Line Fault HandlingAs a fundamental component of the power grid, transmission lines are widely distributed and numerous, often exposed to diverse geographical and climatic conditions, making them highly susceptible to faults. Common causes include overvoltage, pollution flashover, insulation damage, tree encroachment, and external damage. Line tripping is one of the most frequent faults in power plant and substation operations, with fault types including single-phase-to-
Leon
09/04/2025
Seed Inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.