Magnetization Curve of DC Generator

Encyclopedia
Encyclopedia
Field: Encyclopedia
0
China

Magnetization Curve of DC Generator

Key learnings:

  • Magnetization Curve Definition: The magnetization curve of a DC machine shows the relationship between field current and armature terminal voltage on an open circuit.

  • Importance: The magnetization curve indicates the saturation of the magnetic circuit, crucial for understanding the generator’s efficiency.

  • Saturation Point: This point, also known as the knee of the curve, shows where further increases in field current yield minimal increases in flux.

  • Molecular Alignment: As field current increases, magnetic molecules align, increasing flux and generated voltage until saturation.

  • Residual Magnetism: Even when current is zero, some magnetism remains in the generator’s core, influencing the magnetization curve.

图片5.png

DC generator is that curve which gives the relation between field current and the armature terminal voltage on open circuit.

When the DC generator is driven by a prime mover then an emf is induced in the armature. The generated emf in the armature is given by an expression is constant for a given machine.it is replaced by K in this equation.

图片1.png

Here,

φ is the flux per pole,

P is the no. of poles,

N is the no. of revolution made by armature per minute,

Z is the no. of armature conductors,

A is no. of parallel paths.

045fa314adb1b57e317da7a9d65c4b9b.jpeg

Now, from the equation we can clearly see that the generated emf is directly proportional to the product of flux per pole and the speed of the armature.

If the speed is constant, then the generated emf is directly proportional to the flux per pole.

As the excitation current or field current (If) increases, the flux and the generated emf also increase.

图片4.png

If we plot the generated voltage on the Y axis and field current on the X-axis then the magnetization curve will be as shown in the figure below.

The magnetization curve of a DC generator is important because it shows the saturation of the magnetic circuit. This curve is also known as the saturation curve.

According to the molecular theory of magnetism the molecules of a magnetic material, which is not magnetized, are not arranged or aligned in definite order. When current passed through the magnetic material then its molecules are arranged in definite order. Up to a certain value of field current the maximum molecules are arranged. In this stage the flux established in the pole increased directly with the field current and the generated voltage is also increased.

Here, in this curve, point B to point C is showing this phenomena and this portion of the magnetization curve is almost a straight line. Above a certain point (point C in this curve) the nu-magnetized molecules become very fewer and it became very difficult to further increase in pole flux.This point is called saturation point. Point C is also known as the knee of the magnetization curve. A small increase in magnetism requires very large field current above the saturation point. That is why upper portion of the curve (point C to point D) is bend as shown in figure.

Magnetization curve of a DC generator does not start from zero initially. It starts from a value of generated voltage due to residual magnetism.

Residual Magnetism

In ferromagnetic materials, magnetic power and generated voltage increase as current flows through the coils. When the current is reduced to zero, some magnetic power remains in the coil’s core, known as residual magnetism. The core of a DC machine is made of ferromagnetic material.

Give a tip and encourage the author!
Recommended
SST Technology: Full-Scenario Analysis in Power Generation, Transmission, Distribution, and Consumption
SST Technology: Full-Scenario Analysis in Power Generation, Transmission, Distribution, and Consumption
I. Research BackgroundPower System Transformation NeedsChanges in energy structure are placing higher demands on power systems. Traditional power systems are transitioning toward new-generation power systems, with the core differences between them outlined as follows: Dimension Traditional Power System New-Type Power System Technical Foundation Form Mechanical Electromagnetic System Dominated by Synchronous Machines and Power Electronic Equipment Generation-Side Form M
Echo
10/28/2025
Rectifier vs Power Transformer: Key Differences
Rectifier vs Power Transformer: Key Differences
Differences Between Rectifier Transformers and Power TransformersRectifier transformers and power transformers both belong to the transformer family, but they differ fundamentally in application and functional characteristics. The transformers commonly seen on utility poles are typically power transformers, while those supplying electrolytic cells or electroplating equipment in factories are usually rectifier transformers. Understanding their differences requires examining three aspects: working
Echo
10/27/2025
SST Transformer Core Loss Calculation and Winding Optimization Guide
SST Transformer Core Loss Calculation and Winding Optimization Guide
SST High-Frequency Isolated Transformer Core Design and Calculation Material Characteristics Impact:Core material exhibits varying loss behavior under different temperatures, frequencies, and flux densities. These characteristics form the foundation of overall core loss and require precise understanding of nonlinear properties. Stray Magnetic Field Interference:High-frequency stray magnetic fields around windings can induce additional core losses. If not properly managed, these parasitic losses
Dyson
10/27/2025
Upgrade Traditional Transformers: Amorphous or Solid-State?
Upgrade Traditional Transformers: Amorphous or Solid-State?
I. Core Innovation: A Dual Revolution in Materials and StructureTwo key innovations:Material Innovation: Amorphous AlloyWhat it is: A metallic material formed by ultra-rapid solidification, featuring a disordered, non-crystalline atomic structure.Key Advantage: Extremely low core loss (no-load loss), which is 60%–80% lower than that of traditional silicon steel transformers.Why it matters: No-load loss occurs continuously, 24/7, throughout a transformer’s lifecycle. For transformers with low loa
Echo
10/27/2025
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.