Transformerbeskyttelsesinnstillinger: Guide for nullsekvens og overspenning

Vziman
Felt: Produksjon
China

1. Nullsekvens overstrømsvern

Arbeidsstrømmen for nullsekvens overstrømsvernet av jordtransformatorer er vanligvis bestemt basert på transformatorens nominale strøm og den maksimale tillatte nullsekvensstrømmen under systemjordfeil. Den generelle innstillingsspannet er omtrent 0,1 til 0,3 ganger den nominale strømmen, med arbeidstid vanligvis satt mellom 0,5 til 1 sekund for å raskt fjerne jordfeil.

2.Overvoltage Protection

Overvoltage protection is a critical component of grounding transformer protection configuration. For ungrounded neutral systems, when a single-phase ground fault occurs, the voltage of sound phases will rise. The overvoltage protection setting value is generally set at 1.2 to 1.3 times the rated phase voltage to prevent transformer insulation damage from overvoltage conditions.

3.Differential Protection

Differential protection for grounding transformers can effectively distinguish between internal and external transformer faults. The calculation of differential protection operating current must consider factors such as transformer turns ratio and unbalanced current. It is typically set to avoid magnetizing inrush current during transformer energization, approximately 2 to 3 times the rated current.

4.Overcurrent Protection

Overcurrent protection serves as backup protection for grounding transformers. The operating current must avoid the transformer's maximum load current, typically set at 1.2 to 1.5 times the rated current. Operating time is determined based on coordination with upstream and downstream protection devices, generally ranging from 1 to 3 seconds.

5.Zero-Sequence Overvoltage Protection

Zero-sequence overvoltage protection primarily addresses abnormal increases in zero-sequence voltage in the system. Its setting value is determined based on normal zero-sequence voltage fluctuation range during system operation, typically 15 to 30V (secondary side), with operating time generally set between 0.5 to 1 second.

6.Temperature Protection

Temperature protection is crucial for ensuring safe operation of grounding transformers. Resistance temperature detectors (RTDs) or thermocouples are typically used to measure transformer oil and winding temperatures. When oil temperature exceeds 85°C or winding temperature exceeds 100°C, an alarm signal is issued. When exceeding higher set values (oil temperature 95°C, winding temperature 110°C), the protection trips the circuit breaker.

7.Negative-Sequence Current Protection

For grounding transformers, negative-sequence current protection is also an important configuration. The negative-sequence current setting value is determined based on the transformer's capability to withstand negative-sequence current, generally 0.05 to 0.1 times the rated current, to protect the transformer from negative-sequence current effects caused by asymmetrical faults.

8.Over-Excitation Protection

Over-excitation protection is indispensable in grounding transformer protection systems. The over-excitation multiple is typically determined based on the transformer core's saturation characteristics, usually set at 1.1 to 1.2 times rated. When over-excitation occurs, the protection promptly operates to safeguard the equipment.

9.Buchholz Relay Protection (Light Gas)

Light gas protection for grounding transformers activates when minor internal faults occur, producing small amounts of gas that accumulate in the Buchholz relay, causing the oil level to drop. When the oil level drops to a certain degree (typically 25-35mm), the light gas protection operates to send an alarm signal, alerting maintenance personnel to investigate.

10.Buchholz Relay Protection (Heavy Gas)

Heavy gas protection is a critical defense line for grounding transformer protection. When serious internal faults occur in the transformer, producing large amounts of gas and oil flow that impact the Buchholz relay, the heavy gas protection operates to trip the circuit breaker. Its operating flow velocity is generally set between 0.6 to 1 m/s.

Gi en tips og oppmuntre forfatteren

Anbefalt

Intelligente jordingstransformatorer for øygridsupport
1. ProsjektbakgrunnFordelte solenergi (PV) og energilagringprosjekter utvikler raskt seg over hele Vietnam og Sørøst-Asia, men står overfor betydelige utfordringer:1.1 Nettustabilitet:Vietnams kraftnett opplever hyppige fluktuerasjoner (spesielt i nordlige industriområder). I 2023 førte mangel på kullkraft til store strømbrudd, som resulterte i daglige tap over USD 5 millioner. Tradisjonelle PV-systemer mangler effektive evner for nøytral jordforbindelse, noe som gjør utstyr sårbart for skade og
12/18/2025
Funksjoner og valg av jordtransformatorer i solkraftverk
1.Nøytralpunktetablering og systemstabilitetI solcelleanlegg etablerer jordtransformatorer effektivt et systemnøytralpunkt. Ifølge relevante strømregler sikrer dette nøytralpunktet at systemet opprettholder en viss stabilitet under asymmetriske feil, og fungerer som en "stabilisator" for hele strømsystemet.2.Evne til å begrense overspenningFor solcelleanlegg kan jordtransformatorer effektivt begrense overspenninger. Generelt kan de kontrollere overspenningsamplitude innenfor 2,6 ganger systemets
12/17/2025
Elektrisk beskyttelse: Jordtransformatorer og busslading
1. HøyresistansjordningssystemHøyresistansjordning kan begrense jordstrøm og redusere overvoltage på jord på en passende måte. Det er imidlertid ikke nødvendig å koble en stor høyverdis resistor direkte mellom generatorens nøytralpunkt og jord. I stedet kan en liten resistor brukes sammen med en jordtransformator. Primærspolen av jordtransformator er koblet mellom nøytralpunktet og jord, mens sekundærspolen er koblet til en liten resistor. Ifølge formelen er impedansen sett fra primær siden lik
12/17/2025
Koblingsmetoder og parametere for jordtransformatorer
Konfigurasjoner av jordtransformatorvindingerJordtransformatorer deles inn i to typer basert på vindingforbindelse: ZNyn (zigzag) eller YNd. Deres neutrale punkter kan forbinder til en bueløsningsspole eller en jordresistor. For øyeblikket er zigzag (Z-type) jordtransformator forbundet via en bueløsningsspole eller en lavverdi-resistor mer vanlig.1. Z-Type JordtransformatorZ-type jordtransformatorer kommer både i oljeimpregneret og tørre isolasjonstyper. Av disse er harskilt en type tørr isolasj
12/05/2025
Send forespørsel
+86
Klikk for å laste opp fil
Last ned
Hent IEE Business-applikasjonen
Bruk IEE-Business-appen for å finne utstyr få løsninger koble til eksperter og delta i bransjesamarbeid hvor som helst når som helst fullt støttende utviklingen av dine energiprojekter og forretning