6~20kV pre-installed substation high and low voltage wiring scheme

Master Electrician
Master Electrician
Field: Basic Electrical
0
China

6~20kV pre-installed substation high and low voltage wiring scheme

屏幕截图 2024-09-27 141408.jpg

Give a tip and encourage the author!
Recommended
What are the technical measures for loss reduction and energy saving in distribution systems?
What are the technical measures for loss reduction and energy saving in distribution systems?
1.Reasonable Use of TransformersTransformers should be selected with flexible winding configurations according to the power consumption characteristics of industrial enterprises, and load adjustments should be made promptly based on each transformer’s load rate to ensure operation at optimal loading conditions. Three-phase loads on transformers should be kept as balanced as possible; unbalanced operation not only reduces output capacity but also increases losses. Energy-efficient transformers sh
Echo
11/06/2025
What are the advantages of using a common grounding system in power distribution, and what precautions should be taken?
What are the advantages of using a common grounding system in power distribution, and what precautions should be taken?
What Is Common Grounding?Common grounding refers to the practice where a system’s functional (working) grounding, equipment protective grounding, and lightning protection grounding share a single grounding electrode system. Alternatively, it may mean that grounding conductors from multiple electrical devices are connected together and linked to one or more common grounding electrodes.1. Advantages of Common Grounding Simpler system with fewer grounding conductors, making maintenance and inspecti
Echo
11/05/2025
Relay Protection Types in Substations: A Complete Guide
Relay Protection Types in Substations: A Complete Guide
(1) Generator Protection:Generator protection covers: phase-to-phase short circuits in stator windings, stator ground faults, inter-turn short circuits in stator windings, external short circuits, symmetrical overload, stator overvoltage, single- and double-point grounding in the excitation circuit, and loss of excitation. Tripping actions include shutdown, islanding, limiting fault impact, and alarm signaling.(2) Transformer Protection:Power transformer protection includes: phase-to-phase short
Echo
11/05/2025
What Are the Top 10 Taboos and Precautions in the Installation of Distribution Boards and Cabinets?
What Are the Top 10 Taboos and Precautions in the Installation of Distribution Boards and Cabinets?
There are many taboos and problematic practices in the installation of distribution boards and cabinets that must be noted. Especially in certain areas, improper operations during installation may lead to serious consequences. For cases where the precautions were not followed, some corrective measures are also provided here to remedy previous mistakes. Let’s follow along and take a look at common installation taboos from manufacturers regarding distribution boxes and cabinets!1. Taboo: Lighting
James
11/04/2025