What is Sag Template?

Edwiin
Edwiin
Field: Power switch
China

Definition: A sag template is a tool used to accurately determine the positioning and height of supports on a profile. It defines the limits for vertical and wind loads, and also establishes minimum clearance angles between the sag and the ground for safety. Typically crafted from transparent materials such as celluloid or plexiglass (and occasionally cardboard), the sag template features the following marked curves:

  • Hot Template Curve (Hot Curve)

  • Ground Clearance Curve

  • Support Foot or Tower Curve

  • Cold Curve (Uplift Curve)

Detailed explanations of these curves are provided below.

Hot Curve: The hot curve is generated by plotting the sag values at the maximum temperature against the corresponding span lengths. It serves as a guide to determine the precise locations where supports must be positioned to ensure that the specified ground clearance requirements are met.

Ground Clearance Curve: Positioned below the hot curve, the ground clearance curve runs parallel to it. The vertical distance between these two curves is equivalent to the ground clearance value mandated by regulations for the particular line, thereby providing a clear margin for safety and compliance.

Support Foot Curve: This curve is specifically designed to aid in accurately locating the positions of supports for tower lines. It indicates the height measurement from the base of the standard support structure to the attachment point of the lower conductor. In the case of wood or concrete pole lines, however, there is no necessity to draw this curve, as these poles can be installed in any location that offers practical convenience.

Cold Curve or Uplift Curve: The uplift curve is derived by plotting the sag values at the minimum temperature under windless conditions against the span lengths. Its primary purpose is to assess the likelihood of conductor uplift on any support. Uplift of the conductor may occur at low temperatures, especially when one support is significantly lower than its adjacent supports, and this curve helps in identifying such potential scenarios.

Preparation of the Sag Template: Initially, the aforementioned curves are meticulously drawn on graph paper using the same scale as that of the line profile, with appropriate scales carefully selected for accuracy. Subsequently, with the assistance of a sharp - pointed probe, these curves are precisely transferred onto transparent celluloid or perspex sheets. Finally, the celluloid or perspex is cut along the line representing the maximum sag, which is the hot curve, completing the creation of the sag template.

Give a tip and encourage the author!
Recommended
Composition and Working Principle of Photovoltaic Power Generation Systems
Composition and Working Principle of Photovoltaic Power Generation Systems
Composition and Working Principle of Photovoltaic (PV) Power Generation SystemsA photovoltaic (PV) power generation system is primarily composed of PV modules, a controller, an inverter, batteries, and other accessories (batteries are not required for grid-connected systems). Based on whether it relies on the public power grid, PV systems are divided into off-grid and grid-connected types. Off-grid systems operate independently without relying on the utility grid. They are equipped with energy-s
Encyclopedia
10/09/2025
How to Maintain a PV Plant? State Grid Answers 8 Common O&M Questions(2)
How to Maintain a PV Plant? State Grid Answers 8 Common O&M Questions(2)
1. On a scorching sunny day, do damaged vulnerable components need to be replaced immediately?Immediate replacement is not recommended. If replacement is necessary, it is advisable to do so in the early morning or late afternoon. You should contact the power station’s operation and maintenance (O&M) personnel promptly, and have professional staff go to the site for replacement.2. To prevent photovoltaic (PV) modules from being hit by heavy objects, can wire mesh protective screens be install
Encyclopedia
09/06/2025
How to Maintain a PV Plant? State Grid Answers 8 Common O&M Questions(1)
How to Maintain a PV Plant? State Grid Answers 8 Common O&M Questions(1)
1. What are the common faults of distributed photovoltaic (PV) power generation systems? What typical problems may occur in various components of the system?Common faults include inverters failing to operate or start due to voltage not reaching the startup set value, and low power generation caused by issues with PV modules or inverters. Typical problems that may occur in system components are burnout of junction boxes and local burnout of PV modules.2. How to handle common faults of distributed
Leon
09/06/2025
Short Circuit vs. Overload: Understanding the Differences and How to Protect Your Power System
Short Circuit vs. Overload: Understanding the Differences and How to Protect Your Power System
One of the main differences between a short circuit and an overload is that a short circuit occurs due to a fault between conductors (line-to-line) or between a conductor and earth (line-to-ground), whereas an overload refers to a situation where equipment draws more current than its rated capacity from the power supply.Other key differences between the two are explained in the comparison chart below.The term "overload" typically refers to a condition in a circuit or connected device. A circuit
Edwiin
08/28/2025
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.