What is short Circuit Voltage?

Master Electrician
Master Electrician
Field: Basic Electrical
0
China


What is short Circuit Voltage?


Short-circuit voltage definition


The secondary winding of the transformer is shorted, the primary winding is added to the supply voltage, at this time, when the secondary winding flows through the rated current, the voltage value measured at both ends of the primary winding.


Uk%=Ur/Ue ×100%


Physical meaning


Short-circuit voltage is an important characteristic parameter of transformer, which is the basis for calculating the equivalent circuit of transformer and analyzing whether the transformer can run in parallel and separately. When short-circuit occurs on the secondary side of transformer, how much short-circuit current will be generated is also closely related to the impedance voltage. Therefore, it is also an important basis for judging the thermal stability and dynamic stability of short circuit current and determining the setting value of relay protection.


Conversion formula


X=Uk%×Un2×1000/(100Sn)


Standardization of short-circuit voltage


In order to properly deal with the contradictory requirements of normal operation and accident operation, the state gives different regulations on the impedance voltage of various types of transformers. In general, the higher the voltage level, the greater the impedance voltage value. The impedance voltage is standardized to adapt to the parallel operation of transformers because the voltage fluctuations of transformers with different impedance voltages are not the same when loaded.



Give a tip and encourage the author!
Recommended
Maintenance and Repair Items for 10kV High-Voltage Switchgear
Maintenance and Repair Items for 10kV High-Voltage Switchgear
I. Routine Maintenance and Inspection(1) Visual Inspection of Switchgear Enclosure No deformation or physical damage to the enclosure. Protective paint coating shows no severe rust, peeling, or flaking. Cabinet is securely installed, clean on the surface, and free of foreign objects. Nameplates and identification labels are neatly affixed and not falling off.(2) Check of Switchgear Operating Parameters Instruments and meters indicate normal values (comparable to typical operating data, with no s
Edwiin
10/24/2025
Low-Voltage Vacuum Breaker Coil Types & Failures
Low-Voltage Vacuum Breaker Coil Types & Failures
Trip and Close Coils in Low-Voltage Vacuum Circuit BreakersThe trip and close coils are the core components that control the switching state of low-voltage vacuum circuit breakers. When the coil is energized, it generates a magnetic force that drives a mechanical linkage to complete the opening or closing operation. Structurally, the coil is typically made by winding enameled wire on an insulating bobbin, with an outer protective layer, and the terminals are fixed to the housing. The coil operat
Felix Spark
10/18/2025
Constant testing of high-voltage cable lines
Constant testing of high-voltage cable lines
1. Definition of High-Voltage Cable Line Constant TestingHigh-voltage cable line constant testing refers to the systematic measurement, using specialized instruments, of electrical parameters such as resistance, inductance, capacitance, and conductance before a cable line is commissioned or after major maintenance. The aim is to obtain fundamental data characterizing the electromagnetic properties of the cable, serving as a critical testing phase that provides accurate parameter support for powe
Oliver Watts
09/03/2025
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
1.Work Environment Requirements and Safeguard MeasuresBased on technical requirements for cable equipment storage, laying, transportation, laying, transposition, testing, and cable terminations, the project owner and construction units have conducted extensive trials and implemented protective measures regarding ambient temperature, humidity, bending radius, traction control, and route optimization. These measures ensure high-voltage cable quality and on-site safety under harsh winter conditions
James
09/03/2025
Related Products
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.