Access free engineering resources from IEE Business—covering power design, circuit layout, equipment selection, and troubleshooting. Expert-developed guides help engineers, procurement, and project teams make better decisions. Stay ahead on smart grids, renewables, efficiency, and AI tools. Improve reliability, reduce downtime, and enhance outcomes with real-world solutions. Explore our knowledge hub today.
A Brief Analysis of Maintenance and Management of High-Voltage Disconnectors
High-voltage disconnectors are widely used in China’s power systems due to their convenient operation and strong practicality. However, during long-term operation, serious faults such as insulator fracture and failure to open/close still occur, significantly impacting the normal operation of power systems [1]. Based on this, this paper analyzes common faults of high-voltage disconnectors during operation and proposes corresponding solutions based on actual working conditions to improve managemen
11/15/2025
Consult
Tip
Consult
Tip
Winter Maintenance Essentials for GW5-Type Disconnectors
In substations with voltage levels of 110 kV and below, the GW5-type disconnector is widely used due to its simple structure, reliable contact performance, and self-cleaning contact function. Every winter, the failure rate of abnormal heating in GW5-type disconnectors shows an upward trend. Therefore, improving winter maintenance practices for GW5-type disconnectors (hereinafter referred to as “disconnectors”) and promptly detecting and addressing overheating faults are of critical importance to
11/12/2025
Consult
Tip
Consult
Tip
What environments is the 35kV high-voltage disconnector suitable for?
35kV Outdoor Wind-Resistant High-Voltage Disconnector— Suitable for wind farms, overhead line pole-mounted applications, and substation installations.Model series: GW5-40.5 outdoor high-voltage disconnector (hereinafter referred to as “disconnector”).This disconnector is designed for use in 50Hz, 35kV power systems to open or close circuits under no-load voltage conditions. The pollution-resistant variant meets the requirements of users in heavily polluted areas and effectively mitigates polluti
11/11/2025
Consult
Tip
Consult
Tip
Key Operating Procedures for Opening and Closing Isolating Switches and Handling Interlock Failures
When performing switching operations, operating personnel must carefully verify that the circuit breaker is indeed in the open position. For three-pole interlocked isolating switches, all three phases must move simultaneously, with a maximum allowable vertical discrepancy of no more than 3 mm, before any opening or closing operation of the isolating switch is permitted.1. Key Points for Closing an Isolating SwitchFor manual operation, operating personnel should first remove the interlock pin bef
11/10/2025
Consult
Tip
Consult
Tip