Free Expert Guides on Power Systems, Circuit Design & Electrical Troubleshooting

Access free engineering resources from IEE Business—covering power design, circuit layout, equipment selection, and troubleshooting. Expert-developed guides help engineers, procurement, and project teams make better decisions. Stay ahead on smart grids, renewables, efficiency, and AI tools. Improve reliability, reduce downtime, and enhance outcomes with real-world solutions. Explore our knowledge hub today.
What is Mutually Induced EMF?
Definition of Mutually Induced EMFDefinition: The electromotive force (EMF) induced in a coil due to the change in magnetic flux produced by a neighboring coil linked to it is termedmutually induced EMF. To understand this phenomenon, consider the following example:Take coil AB where coil B, having N2 turns, is placed in close proximity to coil A withN1turns, as illustrated in the figure below:Mutually Induced EMF ExplanationWhen switch (S) in the circuit is closed, current I1 flows through coil
05/29/2025
Consult
Tip
Consult
Tip
Leakage Flux And Fringing
Leakage Flux and Fringing Effect AnalysisDefinition: Leakage flux refers to the magnetic flux that deviates from the intended path in a magnetic circuit. This can be illustrated using a solenoid to distinguish between leakage flux and fringing effect:When current passes through a solenoid, most flux forms the main flux along the core axis, while a fraction leaks outside the coil without fully following the core path—this is leakage flux. In a long solenoid, leakage flux primarily occur
05/28/2025
Consult
Tip
Consult
Tip
What is the research on the intelligent monitoring system for the operating status of high-voltage disconnectors?
1. IntroductionHigh voltage disconnect switches (HVDs), particularly 145kV models, are critical for power grid safety in Indonesia, where tropical climates and complex terrain pose unique operational challenges. This article presents an intelligent monitoring system (IMS) designed to address these challenges, integrating IP66 - rated environmental protection and compliance with IEC 60068 - 3 - 3. The system leverages sensor networks, data analytics, and remote control to enhance the reliability
05/28/2025
Consult
Tip
Consult
Tip
High Voltage Disconnect Switch: Practical Applications and Development Trends
High Voltage Disconnect Switch: Practical Applications and Development Trends1. IntroductionHigh voltage disconnect switches (HVDs) are pivotal components in electrical power systems. Their fundamental function is to isolate electrical equipment or circuits from the power supply, ensuring safety during maintenance, repair work, or in emergency situations. In a country like Indonesia, with its expanding power infrastructure and diverse geographical conditions, the role of HVDs, especially those r
05/28/2025
Consult
Tip
Consult
Tip
What requirements should be met for the maintenance of high-voltage disconnect switches?
Maintenance Requirements for High-Voltage Disconnect Switches in Indonesia: Focus on 72kV Systems with IP66 Protection1. IntroductionHigh-voltage disconnect switches (HVDs) are critical components in Indonesia's power grid, ensuring safe isolation of electrical equipment during maintenance and system operations. In a country characterized by tropical climates, high humidity, and diverse environmental conditions, maintaining 72kV HVDs with strict standards is paramount. This article outlines the
05/28/2025
Consult
Tip
Consult
Tip
Series Magnetic Circuit
Definition of Series Magnetic CircuitDefinition: A series magnetic circuit is defined as a magnetic pathway composed of multiple sections with varying dimensions and materials, all carrying the same magnetic field. Consider a circular coil or solenoid with distinct dimensional parameters, as illustrated in the figure below:Series Magnetic Circuit AnalysisA currentIflows through a solenoid withNturns wound around one section of a circular coil, inducing a flux Φ in the core. a₁, a₂, a₃: C
05/28/2025
Consult
Tip
Consult
Tip
Parallel Magnetic Circuit
Definition of Parallel Magnetic CircuitA parallel magnetic circuit is defined as a magnetic pathway with two or more branches for magnetic flux, analogous to a parallel electric circuit. Such circuits feature multiple flux paths with varying cross-sectional areas and materials, each potentially composed of different magnetic components.Parallel Magnetic Circuit AnalysisThe figure above depicts a parallel magnetic circuit, where a current-carrying coil is wound around the central limb AB. This co
05/28/2025
Consult
Tip
Consult
Tip
EMF Equation of a Transformer
Background of Transformer EMF Equation DerivationWhen a sinusoidal voltage is applied to the transformer's primary winding, an alternating flux ϕmis induced in the iron core. This sinusoidal flux links both primary and secondary windings, with its functional form described by a sine function.Mathematical Derivation of Flux Rate of ChangeThe following outlines the derivation of the transformer's EMF equation, with defined parameters: ϕm: Maximum flux (Weber) f: Supply frequency (Hz) N1: Number of
05/28/2025
Consult
Tip
Consult
Tip
Resistance and Reactance of the Transformer
Transformer Resistance and Reactance RepresentationResistance DefinitionThe resistance of a transformer refers to the internal resistance of its primary and secondary windings, denoted as R1 andR2. Corresponding reactances are X1 andX2, withKrepresenting the transformation ratio. To simplify calculations, impedances can be referred to either winding—either primary terms referred to the secondary side or vice versa.Voltage Drops in WindingsResistive and reactive voltage drops in primary
05/28/2025
Consult
Tip
Consult
Tip
Transformer on No Load Condition
No-Load Operation of TransformerWhen a transformer operates under no-load conditions, its secondary winding is open-circuited, eliminating load on the secondary side and resulting in zero secondary current. The primary winding carries a small no-load currentI0, comprising 2 to 10% of the rated current. This current supplies iron losses (hysteresis and eddy current losses) in the core and minimal copper losses in the primary winding.The lag angle ofI0is determined by transformer losses, with the
05/28/2025
Consult
Tip
Consult
Tip