Free Expert Guides on Power Systems, Circuit Design & Electrical Troubleshooting

Access free engineering resources from IEE Business—covering power design, circuit layout, equipment selection, and troubleshooting. Expert-developed guides help engineers, procurement, and project teams make better decisions. Stay ahead on smart grids, renewables, efficiency, and AI tools. Improve reliability, reduce downtime, and enhance outcomes with real-world solutions. Explore our knowledge hub today.
Location of Hazard Points and Safety Control Technology for High - voltage SF₆ Circuit Breakers
High - voltage SF₆ circuit breakers are the most widely used switchgear in substations. Regular inspection and maintenance of them are crucial for ensuring the stable operation of the power system. However, in the substation maintenance field, especially during the maintenance of high - voltage SF₆ circuit breakers, there are numerous hazard points (such as poisoning, electric shock, etc.), which seriously threaten the personal safety of workers. Based on this, this paper analyzes from the persp
05/08/2025
Consult
Tip
Consult
Tip
Analysis of the breakdown fault of the SF6 circuit breaker in a 750 kV substation
Due to its excellent electrical insulation properties and arc - extinguishing capabilities, sulfur hexafluoride (SF₆) gas has been widely used in high - voltage and extra - high - voltage power systems. Compared with traditional circuit breakers, SF₆ circuit breakers are more reliable and have a longer service life. However, as the usage time and load increase, the faults of SF₆ circuit breakers gradually emerge, especially the breakdown faults, which have become a hidden danger to the safe oper
05/08/2025
Consult
Tip
Consult
Tip
Circuit breakers basic control circuit functions diagram
Circuit Breakers Control Circuit Functions Diagram Description Circuit Breaker Main Contacts: These are not part of the control circuit. They serve as the primary conducting elements that open and close to interrupt or establish the main electrical circuit. Mechanical Operating Mechanism: This mechanism releases the energy required to move the main contacts between the open and closed positions. It is also excluded from the control circuit proper. Its role is crucial in physically actuating the
05/07/2025
Consult
Tip
Consult
Tip
What is Electronic Relay?
Definition and Basics of Electronic RelaysDefinition: An electronic relay is an electronic switch that operates to open or close circuit contacts using electronic components, eliminating the need for any mechanical movement. In electrical systems, the current carrier pilot relaying scheme is commonly employed in these relays for the protection of transmission lines. This approach enables efficient and precise detection of faults, ensuring the safety and reliability of the power grid.Electronic r
05/05/2025
Consult
Tip
Consult
Tip
Typical mechanical interlocks role for draw out circuit breakers in LV switchgears according to IEEE standard
Safety Features and Requirements for Circuit Breakers Interlocking to Prevent Unauthorized Movement: To ensure operational safety, it is imperative to prevent the movement of a circuit breaker to or from the connected position when the circuit breaker itself is in the closed state. This safeguard helps avoid potential electrical hazards and damage to the equipment. Pre - closing Conditions: Additionally, measures are in place to prevent the closing of the circuit breaker unless the primary disco
04/30/2025
Consult
Tip
Consult
Tip
Percentage Differential Relay
Definition: A percentage differential relay is defined as a type of relay that functions based on the phase difference of two or more similar electrical quantities. It represents an advanced form of differential protection relay. The sole distinction between it and other differential relays lies in the presence of a restraining coil. The percentage differential relay incorporates a restraining coil precisely to address issues stemming from discrepancies in the current ratio when dealing with hig
04/29/2025
Consult
Tip
Consult
Tip
Temperature-Rise test of Large Capacity Generator Circuit Breaker
The temperature rise test is a crucial test for generator circuit breakers to verify their current - carrying capacity. In this test, the maximum test current can reach as high as 35 kA to simulate the real operating environment. The test sample is a complete three - phase installation, but the test is only conducted on a single phase. The air temperature can be adjusted using cooling water.The implementation of this test mainly focuses on the following three aspects, and the layout of the exper
04/29/2025
Consult
Tip
Consult
Tip
Generator circuit breakers(GCB) role in gas turbine power plants
When starting a gas - turbine generator, its rotor must first be accelerated by external means to approximately 60% of the rated speed. Only then does the start - up process become self - sustaining, meaning the turbine can generate enough power to continue the process independently. To achieve this initial acceleration, energy can be supplied by various means, with a static frequency converter (SFC) being a common choice.Generator circuit breakers (GCBs) play a crucial role in this process. The
04/26/2025
Consult
Tip
Consult
Tip
Testing of Circuit Breaker
Circuit Breaker Testing: Challenges and ProceduresTesting circuit breakers is a far more intricate task compared to testing other electrical equipment such as transformers or machines, primarily due to the extremely large magnitudes of short - circuit currents involved. In contrast, the testing of transformers is typically categorized into two main groups: type tests and routine tests.Type Tests of Circuit BreakersType tests are essential for validating the capabilities and confirming the rated
04/25/2025
Consult
Tip
Consult
Tip
Air Blast Circuit Breaker
Air Blast Circuit Breakers: Operation, Advantages, and TypesAn air blast circuit breaker utilizes compressed air or gas as the arc - interrupting medium. Compressed air is stored in a tank and, when needed, released through a nozzle to generate a high - velocity jet. This jet plays a crucial role in extinguishing the arc that forms when the circuit breaker interrupts the electrical current.Air blast circuit breakers are commonly employed for indoor applications in the medium - high voltage range
04/25/2025
Consult
Tip
Consult
Tip
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.