Search


VD4 MV Vacuum Circuit Breakers
Brochure · ROCKWILL

VD4 MV Vacuum Circuit Breakers

12‑24 kV indoor vacuum circuit‑breaker, 630‑4000A rated current, 20‑40kA short‑circuit breaking, M2/E2/C2 class, modular spring‑mechanism, up‑to‑30000 maintenance‑free mechanical‑cycles for primary distribution switchgear.

Add us on Google
Updated2026.09
LanguageEnglish
FilePDF · 296.3 KB
VD4 MV Vacuum Circuit Breakers
Download

Document description

This PDF product flyer targets power utilities, EPC contractors and panel‑builders for tender comparison, cabinet‑type‑selection and pre‑sales technical evaluation. This indoor vacuum circuit‑breaker complies with IEC 62271‑1, IEC 62271‑100 and relevant ANSI standards.

It adopts vacuum‑interrupter with modular spring‑stored‑energy operating‑mechanism, achieving up‑to‑30 000 overhaul‑free mechanical operations, and meets M2 mechanical‑class, E2 electrical‑endurance and C2 capacitive‑current‑breaking‑class.

This flyer records complete dielectric‑withstand values, making‑breaking‑capacity, O‑0.3s‑CO‑15s‑CO operating‑sequence, opening‑closing‑arcing‑time parameters, 4‑second short‑time withstand‑current, control‑voltage range 24‑250 V, secondary‑circuit insulation‑level, ‑15 ℃ ~ +40 ℃ operating‑temperature.

It supports rich standardized accessories & spare‑parts, and offers custom‑manufacturing including parameter adjustment, accessory configuration and project‑specific factory‑acceptance‑test for transformer, motor, capacitor‑bank and overhead‑cable protection scenarios. Please contact us for dimension drawings and full‑set type‑test‑reports.

Related Products

Frequently asked questions

It complies with IEC 62271 series, UTE NFC standards, RoHS and REACH requirements. Production site holds ISO 9001 and Green Premium sustainability certification.

Custom‑available items include parameter tuning, coil‑voltage selection, accessory‑combination optimisation and project‑specified factory‑acceptance‑test‑items. Please contact us to submit your technical‑specification.

Need to verify installation‑dimensions, rack‑in‑out interface, interlock‑logic, secondary‑wiring arrangement and control‑coil‑voltage of original cabinet. Please contact us for retrofit‑assessment support.

WhatsApp
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.
Login
or continue with
New here?
Register