• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


RHD-362 SF6 Gas Dead tank Circuit Breaker
Drawings · ROCKWILL

RHD-362 SF6 Gas Dead tank Circuit Breaker

Widely used in 362kV EHV transmission substations, power plant switchyards, hybrid gas insulated switchgear projects for power grid switching, overload and short-circuit fault protection.

Updated2026.09
LanguageEnglish
FilePDF · 419.2 KB
Dead tank Circuit BreakerSF6 Gas Circuit Breaker
Download

Document description

This drawing specifies outline dimension and performance indexes of RHD-362 SF6 dead tank circuit breaker.

RHD-362 is SF6 gas insulated dead tank circuit breaker complying with IEC 62271-1 and IEC 62271-100 and KEMA type tested. Rated voltage 362kV, rated current up to 5000A, short-circuit breaking current up to 63kA. It adopts self-blast arc quenching and oil-free pure spring operating mechanism. Bushing-integrated CT is optional. It is widely applied for circuit switching and fault protection in 362kV extra-high voltage transmission substations.

Related Products

Frequently asked questions

In a live tank breaker, the arc chamber is mounted at the top or side of the column, exposed to ambient air. In a dead tank breaker, the arc chamber is placed inside the metal tank, fully sealed.

 Live tank breakers are well-suited for outdoor high-voltage distribution with a dispersed layout. Dead tank breakers flexibly adapt to both indoor and outdoor applications, especially in space-constrained substations or where compact installation is required.

The RHD series features a specialized low-center-of-gravity design that provides 9-grade seismic resistance. This ensures the Dead Tank Vacuum Circuit Breaker remains structurally sound and maintains rock-solid performance even during high-intensity earthquake events, making it a proven choice for high-risk geographical areas.

Q:How does the Dead Tank Vacuum Circuit Breaker achieve zero-pollution operation?

A:Unlike traditional high-voltage equipment, this Dead Tank Vacuum Circuit Breaker uses high-vacuum technology (degree 10⁻⁴Pa) for arc extinction instead of SF6 gas. By eliminating greenhouse gases, it removes the risk of toxic leaks and aligns with global green energy trends and strict environmental standards.

Q:Can this Dead Tank Vacuum Circuit Breaker be customized for non-standard power grids?

A:Yes, we offer "all-round customization" for the Dead Tank Vacuum Circuit Breaker. While it covers standard 40.5kV to 252kV grades, we can craft seamless-fit solutions for non-standard voltages (such as 46kV, 69kV, or 75kV) and current ratings from 1250A up to 6300A in single, two, or three-phase configurations.

Q:What are the maintenance benefits of using a Dead Tank Vacuum Circuit Breaker ?

A:The RHD series is designed to be virtually maintenance-free. It utilizes an oil-free and gas-free spring-operated mechanism and a vacuum interrupter rated for over 10,000 cycles. Additionally, every Dead Tank Vacuum Circuit Breaker is fully assembled and tested at the factory, so no on-site disassembly or high-voltage testing is required during installation.

WhatsApp