• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


RHD-40.5 Dead tank SF6 gas circuit breaker FLYER
Brochure · ROCKWILL

RHD-40.5 Dead tank SF6 gas circuit breaker FLYER

40.5kV SF6 dead‑tank circuit‑breaker, rated current 1600‑3150A, short‑circuit breaking current 25‑31.5kA, self‑blast arc‑extinguishing, three‑phase post‑type porcelain insulator for outdoor substation.

Updated2026.09
LanguageEnglish
FilePDF · 142.3 KB
SF6 gas circuit breakerDead tank Dead tank
Download

Document description

This PDF product flyer is a technical reference for medium‑high‑voltage SF6 dead‑tank circuit‑breaker, used for tender comparison, preliminary project selection and pre‑sales technical evaluation. The product follows IEC 62271‑100 and GB/T 1984 standards.

This datasheet records full‑set performance indicators including lightning impulse and one‑minute power‑frequency withstand voltage, creepage distance, partial discharge requirement, SF₆ alarm‑blocking pressure threshold, gas moisture limit, annual gas leakage rate, mechanical operating life, first‑open‑pole factor 1.5, 4‑second short‑circuit duration and O‑0.3s‑CO‑180s‑CO special reclosing operation sequence.

It is equipped with pointer‑type density relays to monitor SF6 pressure and density in real‑time, and specifies power‑supply parameters for anti‑condensation heater, energy‑store motor and control circuit. Custom‑manufacturing services covering design, assembly and factory test are available for substation projects. Please contact us to get complete outline dimension drawings and full set of type‑test reports.

Related Products

Frequently asked questions

Low partial discharge value proves sound internal insulation, reduces insulation ageing risk and extends the whole service life of high‑voltage equipment. Please contact us for relevant test data.

It reflects the capability to switch on and off no‑load overhead lines, an important indicator for distribution and substation equipment selection. Please contact us for application boundary explanation.

Excessive moisture may cause internal condensation, reduce dielectric strength and accelerate corrosion of internal metal and insulating components. Please contact us for on‑site gas handling guidance.

WhatsApp
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.
Login
or continue with
New here?
Register