• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


EEHC Distribution materials specification for 24kv ring mian units
Others · ROCKWILL

EEHC Distribution materials specification for 24kv ring mian units

Egypt urban medium voltage distribution network, indoor distribution substations, solar power plant collector switchgear, industrial park power supply, compact prefabricated substation, rural grid upgrading projects under EEHC framework.

Updated2026.09
LanguageEnglish
FilePDF · 572.6 KB
Distribution materials specification24kv ring mian unitsEEHC

Document description

This document applies to the technical requirements for the design, testing, supply, installation, and related supporting equipment (sensors, controllers, cables, etc.) of  Ring Main Units  on EEHC in 24kV HV Switchgear.

ROCKWILL 24kV Ring Main Unit is engineered to fully comply with EEHC Distribution Materials Specification EDMS 02-202-1 for Egyptian medium voltage distribution network. It covers both gas-insulated (GIS) and air-insulated (AIS) type, rated voltage 24kV, rated current up to 630A /1250A, short-time withstand current 20kA,25kA for 3 seconds. Primary conductors adopt high conductivity copper with silver-plated contact surfaces. Stainless steel welded gas tank for GIS version, fully mechanical five-prevention interlock, optional motorized actuator and DTU for distribution automation. Type tests shall be performed in accordance with IEC 62271 series standards and EEHC mandatory test clauses, suitable for urban distribution, solar farm and indoor substation projects in Egypt.

Related Products

Frequently asked questions

EEHC Distribution materials specification for 24kV ring main units requires main busbar to be high conductivity copper with silver-plated contact surfaces. The earthing busbar shall be copper with cross-section not less than 150 mm², capable to withstand the full rated short-time fault current for 3 seconds.

 EEHC Distribution materials specification for 24kV ring main units accepts both SF6 gas insulated (GIS) and air insulated (AIS) 24kV ring main units. The RMU shall be manually operable as standard design and retain mechanical interface for future motorized actuator and SCADA automation retrofit.

EEHC Distribution materials specification for 24kV ring main units mandates full set mechanical five-prevention interlock system. It shall mechanically block forbidden operations such as closing onto earth, earthing on live circuit, access to live compartment and wrong sequence operation.

EEHC Distribution materials specification for 24kV ring main units (EDMS 02-202-1) is the official technical document issued by Egyptian Electricity Holding Company. It defines the minimum material, design, test & supply requirements of 24kV GIS/AIS ring main units for Egyptian national medium voltage distribution network, applicable for tendering, factory acceptance and site commissioning.

EEHC Distribution materials specification for 24kV ring main units requires a complete IEC type test package including insulation test, temperature rise, short-time withstand current, load switching, partial discharge, internal arc test and environmental aging test, and witness test can be arranged for EEHC inspector.

WhatsApp