Outdoor LV Pole‑Mounted Circuit‑breaker, rated 440V, 165‑265A, for 50/100/160kVA pole‑mount transformers. 4‑pole, air arc‑extinguishing, integrated digital trip unit, pole‑mount type, ‑40℃~+70℃ wide ambient temperature range.

Add us on Google
Updated2026.10
LanguageEnglish
FilePDF · 474.3 KB
LV Pole Mounted BreakerD165T LV Pole Mounted BreakerD265T LV Pole Mounted Breaker

Document description

This document introduces outdoor LV pole‑mounted circuit‑breaker complying with HN 63‑S‑11 and IEC 60947‑2:2024 standards, specially developed for protection of outdoor pole‑mount distribution transformers.

It adopts weather‑proof GRP enclosure and air‑type arc‑extinguishing with metal grid arc chute. Integrated digital trip unit supports 50kVA, 100kVA, 160kVA transformer ratings, covering balanced & unbalanced three‑phase overload and cumulative‑overload trip function.

4‑pole construction (3 protected poles plus neutral pole), operated via ground‑level linkage handle with padlock‑capable anti‑tamper feature. Neutral‑to‑earth connection for transformer neutral is realised when breaker is open. Documentation covers outline dimension, pole‑mount layout drawing, wiring schematic and internal assembly drawing.

Cable specification, installation requirements, trip‑time characteristics under varying temperature and periodic maintenance instructions are documented.

Widely used for pole‑mount transformer protection in rural and suburban overhead‑line distribution networks against overload, short‑circuit and phase‑unbalance faults.

Related Products

Frequently asked questions

Outline drawing, pole‑mount installation sketch and wiring schematic are available. Test reports complying with HN 63‑S‑11 and IEC 60947‑2 are supplied. Support includes capacity‑selection consultation and tender‑phase technical documentation.

There is no auto‑reclose function. Manual reset via ground‑level handle is required after every trip. Troubleshoot transformer and LV circuit before reset & close. Forced reset with existing fault is strictly prohibited.

Breaker body is fitted upper‑mid pole, connected to ground handle by standard metal drive pipe. It fits circular utility pole by default; square pole shall be specified at order stage. Split pin must lock linkage pin to avoid dropping during operation. Padlock can be applied on ground handle to prevent unauthorised operation.

Conventional overload protection monitors real‑time current only. Cumulative‑overload trip calculates thermal accumulation considering current magnitude, duration and ambient temperature, simulating real transformer thermal ageing. Short‑time overload is permitted; tripping triggers only when total thermal stress exceeds limit, better matching transformer thermal behaviour.

Each setting corresponds to rated capacity of protected pole‑mount transformer with dedicated overload, unbalance and short‑circuit trip curves per HN 63‑S‑11. Setting can be switched on‑site to match actual transformer without hardware replacement.

Comments

Share your question or perspective
WhatsApp
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.
Login
or continue with
New here?
Register