Commercial Wall-mounted DC EV Charger
Wall-mount DC charger: 20/30/40kW, input ≤36/54/72A. Power-electronic device; no primary switchgear parameters. Short-circuit & lightning protection via external distribution.
Wall-mount DC charger: 20/30/40kW, input ≤36/54/72A. Power-electronic device; no primary switchgear parameters. Short-circuit & lightning protection via external distribution.
Wall‑mount DC charger 20‑40kW, wall‑installation with expansion bolts, bottom‑incoming cables. Requires external residual‑current, short‑circuit and lightning protection. No explicit IEC number in manual, generally complies with IEC 61851‑23, IEC 61851‑1 EV charging standards.
Wall‑mount installation with M860 expansion bolts. Required tools: electric drill, M12 drill bit, multimeter, Phillips /flat‑head screwdriver, M13 wrench etc. Drill hole depth shall be 45‑50 mm.
20kW recommends 6mm² copper cable with 40A residual‑current breaker; 30kW recommends10mm² copper cable with 64A breaker; 40kW recommends16mm² copper cable with 80A breaker. Distribution cabinet shall be equipped with over‑current, short‑circuit and lightning protection.
Check equipment shell for damage, paint peeling; inspect cable sheath integrity; check charging gun for breakage and no foreign matter inside gun head; measure for AC input short‑circuit with multimeter; confirm insulation & grounding meet requirements.