Commercial Wall-mounted DC EV Charger
Wall-mount DC charger: 20/30/40kW, input ≤36/54/72A. Power-electronic device; no primary switchgear parameters. Short-circuit & lightning protection via external distribution.
Wall-mount DC charger: 20/30/40kW, input ≤36/54/72A. Power-electronic device; no primary switchgear parameters. Short-circuit & lightning protection via external distribution.
Wall‑mount DC charger 20‑40kW, wall‑installation with expansion bolts, bottom‑incoming cables. Requires external residual‑current, short‑circuit and lightning protection. No explicit IEC number in manual, generally complies with IEC 61851‑23, IEC 61851‑1 EV charging standards.
Instalación en pared con pernos de expansión M860. Herramientas necesarias: taladro eléctrico, broca M12, multímetro, destornillador Phillips/de punta plana, llave M13, etc. La profundidad de perforación deberá ser de 45-50 mm.
Para 20 kW se recomienda un cable de cobre de 6 mm² con un interruptor diferencial de 40 A; para 30 kW se recomienda un cable de cobre de 10 mm² con un interruptor de 64 A; para 40 kW se recomienda un cable de cobre de 16 mm² con un interruptor de 80 A. El armario de distribución deberá estar equipado con protección contra sobrecorrientes, cortocircuitos y descargas atmosféricas.
Inspeccione la carcasa del equipo en busca de daños o desprendimiento de pintura; verifique la integridad de la cubierta del cable; compruebe la pistola de carga en busca de roturas y asegúrese de que no haya objetos extraños en el interior de la cabeza de la pistola; mida con un multímetro para detectar cortocircuitos en la entrada de CA; confirme que el aislamiento y la puesta a tierra cumplen con los requisitos.