1. Background ng Proyekto
Ang mga proyektong distributibong photovoltaic (PV) at pag-imbak ng enerhiya ay lumalago nang mabilis sa Vietnam at Southeast Asia, ngunit naranasan ang malubhang mga hamon:
1.1 Kabuluhan ng Grid:
1.2 Pagganap sa Polisiya at Seguridad:
1.3 Mga Kahitinan sa Kapaligiran:
2. Solusyon: Intelligent High-Voltage Disconnecting Switch System
2.1 Core Technology Design
Ginagamit ang double-break rotary structure, rated voltage ≥15kV, rated current 6300A (forced air-cooling design), na sumasaklaw sa pangangailangan ng malaking distributibong power plants.
Pag-optimize ng Pag-extinguish ng Arc:May built-in magnetic blowout arc extinguishing devices, DC arc breaking time ≤20ms, na nagpapahintulot na hindi magkaroon ng apoy dahil sa arc faults. Ang mabilis na pag-extinguish ng arc ay isang mahalagang safety feature ng High voltage Disconnect Switch.
Ang enclosure ay may IP65 protection rating; ang core components ay ginto-plated upang makatipon sa corrosion ng salt spray (sumasang-ayon sa IEC 60068-2-52 standard). Ang mga proteksyon na ito ay nag-aasure ng long-term reliability ng High voltage Disconnect Switch.
Thermal Design:Idinagdag ang aluminum alloy heat sinks, temperature rise controlled at ≤40K (sa 40°C ambient). Ang epektibong thermal management ay mahalaga para sa High voltage Disconnect Switch sa mga tropikal na klima.
2.2 Intelligent Monitoring and Protection System
Real-time monitoring ng contact temperature, arc signals, at insulation status; data synchronized sa local SCADA at cloud platforms (e.g., Hoymiles S-miles Cloud) sa loob ng milliseconds. Ang continuous monitoring ay nagpapataas ng safety profile ng High voltage Disconnect Switch.
Collaboration with Circuit Breakers:Automatically opens within 10 seconds upon detecting grid voltage drop to 20% UN (meeting Vietnam's low-voltage lockout requirement).
Cooperation with AFCI (Arc Fault Circuit Interrupter) System:Cuts off the fault circuit within 0.5 seconds. This fast protection logic integrates seamlessly with the High voltage Disconnect Switch.
2.3 Localized Adaptation Improvements
Supports EVN-required islanding test mode, simulating seamless switch to energy storage supply after grid interruption. The High voltage Disconnect Switch is integral to passing this critical test.
Pre-installed sealing wire interfaces to meet Vietnam's mandatory metering room sealing requirements.
Contact lifespan ≥10,000 operations; maintenance cycle extended to 5 years, reducing O&M costs in tropical regions. The durability of the High voltage Disconnect Switch significantly lowers lifetime costs.
3. Nakamit na Resulta
3.1 Pinataas na Seguridad at Reliability
3.2 Economic Benefits and Compliance
3.3 Pinatatag na Kakayahan ng Grid Support
Passed dynamic curtailment clause testing: Supports power regulation of up to 30% installed capacity under EVN's flexible dispatch (when grid load <75%), enabling power plants to participate in the Frequency Regulation Market (FRP). The High voltage Disconnect Switch contributes to this grid support functionality.