• Large-Capacity High-Speed Current-Limiting Circuit Breaker
Large-Capacity High-Speed Current-Limiting Circuit Breaker
discuss personally
Model
DGK-24/100
Basic info
Brand RW Energy
Model NO. Large-Capacity High-Speed Current-Limiting Circuit Breaker
Rated voltage 24kV
Rated normal current 100A
Rated frequency 50/60Hz
Series DGK
Product Detail

Product Introduction

  • The DGK is mainly applied in low-current systems, with a rated current of <630A and a rated breaking current of ≤200kA.

  • The DGK can complete current limiting and interrupt short-circuit current within 10ms, ensuring that the actual current present in the fault circuit is only 15~50% of the expected short-circuit current.

  • TXB3 = DGK + switchgear cabinets with different configurations. The TXB3 is assembled by connecting the DGK in series with general-purpose switchgear such as vacuum circuit breakers, load switches, or disconnectors. For normal switching operations and operations involving load current or overload current, these are performed via the switchgear (load switches or circuit breakers) integrated in the TXB3 device.

  • This product not only achieves low-cost interruption of short-circuit current but also eliminates the need to upgrade the dynamic and thermal stability parameters of relevant electrical equipment in branch circuits. Thus, it realizes rational circuit design and reduces the investment cost of project equipment.

Product Features and Benefits

  • Fast breaking speed (high speed), the whole breaking time is less than 10ms

  • The opening process has obvious current limiting characteristics (current limiting)

  • It is mainly used in small rated current systems

  • According to the needs of the project, the non-standard cabinet type is assembled, and there are a variety of configuration schemes

  • Reduce the cost of a large number of substation replacements of switches and other main equipment

Main technical parameters

serial number

Parameter Name

unit

Technical parameters

1

Rated voltage

kV

3.6~24

2

Rated current

A

6.3~500

3

Rated expected short-circuit breaking current

kA

20-120

4

Current limit coefficient = cut-off current / expected short-circuit current peak

%

15~50

5

Insulation level

Power frequency withstand pressure

       kV/1min

42/48

Lightning impact withstand pressure

            kV

75/85kV

Product Usage

  • Fast short-circuit protection of power branch bus in hydropower plants, limiting and quickly interrupting high-amplitude short-circuit current, avoiding the use of expensive generator circuit breakers, and improving technical economy

  • Large synchronous motor outlet

  • For fast breaking and rapid isolation of fault points in feeders prone to short circuit faults

 

Know your supplier
RW Energy
Zhejiang Rockwell Energy Technology Co., Ltd. is an international enterprise specializing in the research, development and manufacturing of recloser controllers, power quality management, power monitoring systems and other high-end power equipment. In today's critical period of global energy transition and power system upgrading, the company has gathered a group of top talents in the fields of power engineering, automation control, software development, etc., who carry the enthusiasm and persistence for the power business, and are committed to overcoming the complex problems in the power system, and promoting the intelligent development of the power industry with innovative technology. Mission: To make global electricity smarter, more reliable and more efficient with innovative technology. Vision: To be the leader in global power intelligence.
Main Categories
High Voltage Electrical Apparatus/New energy/Tester
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$100000000
Professional Experience
12 years
Workplace
30000m²
占位
占位
Related Products
Related Knowledges
What is the difference between a dielectric and an insulator?
What is the difference between a dielectric and an insulator?
Dielectrics and insulators are distinguished primarily by their applications. One of the main differences is that a dielectric can store electrical energy by becoming polarized in an electric field, whereas an insulator resists the flow of electrons to prevent current conduction. Other key differences between them are outlined in the comparison chart below.Definition of DielectricA dielectric material is a type of insulator that contains few or no free electrons. When subjected to an electric fi
Edwiin
08/30/2025
Fault Analysis and Treatment of Oil-Immersed Transformers
Fault Analysis and Treatment of Oil-Immersed Transformers
Oil Leakage at Welded JointsOil leakage at welded joints primarily stems from poor welding quality, such as incomplete or detached welds, and defects like pinholes and gas pores. Although oil-immersed transformers are initially coated with solder and paint during manufacturing, potentially masking these issues temporarily, the defects tend to surface during operation. Additionally, electromagnetic vibration can cause weld cracks, leading to oil leakage.To resolve such leaks, the first critical s
Edwiin
08/29/2025
What losses occur during operation of the transformer? How to reduce losses?
What losses occur during operation of the transformer? How to reduce losses?
Transformers experience various types of losses during operation, primarily categorized into two main types: copper losses and iron losses.Copper LossesCopper losses, also known as I²R losses, are caused by the electrical resistance of the transformer windings—typically made of copper. As current flows through the windings, energy is dissipated in the form of heat. These losses are proportional to the square of the load current (I²R), meaning they increase significantly with high
Rockwell
08/29/2025
Cable Fault Detection, Testing, Location and Repair
Cable Fault Detection, Testing, Location and Repair
I. Methods for Cable Testing and Inspection:Insulation Resistance Test: Use an insulation resistance tester to measure the insulation resistance value of the cable. A high insulation resistance value indicates good insulation, while a low value may suggest insulation problems requiring further investigation.Voltage Withstand Test: Apply a high-voltage test using a high-voltage tester to verify whether the cable can withstand high voltage under its rated operating conditions. Under normal circums
Leon
08/29/2025
Cable Quality Inspection and Cable Detection & Testing
Cable Quality Inspection and Cable Detection & Testing
Power cable quality inspection and cable testing are conducted to ensure that the cable's quality and performance meet specified requirements, thereby guaranteeing the safe and stable operation of power systems. Below are some common contents of power cable quality inspection and cable testing:Visual Inspection: Check the cable surface for physical defects such as damage, deformation, or scratches to ensure the cable's exterior is intact.Dimensional Measurement: Measure dimensional parameters su
Edwiin
08/29/2025
Transformer Detection, Testing, Maintenance and Servicing
Transformer Detection, Testing, Maintenance and Servicing
Transformer testing, inspection, and maintenance are essential tasks to ensure normal operation and extend the service life of transformers. Below are some recommended steps:Visual Inspection: Regularly inspect the transformer's exterior, including the enclosure, cooling system, and oil tank. Ensure the enclosure is intact, free from corrosion, damage, or leakage.Insulation Resistance Testing: Use an insulation resistance tester to check the transformer's insulation system. Verify that the insul
Vziman
08/29/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!