• AC voltage detector pen Tester with vibration mode HLX
  • AC voltage detector pen Tester with vibration mode HLX
  • AC voltage detector pen Tester with vibration mode HLX
  • AC voltage detector pen Tester with vibration mode HLX
AC voltage detector pen Tester with vibration mode HLX
$87.00
Model
VT-1000
VT-1000E
Basic info
Brand Wone
Model NO. UT12E-US UT12E-EU ac voltage detector pen Tester with vibration mode HLX
AC voltage 90V~1000V (high)
Frequency range 50/60Hz
Series VT12E-EU
Product Detail

Dscription

UT12E-EU and UT12M-EU are professional grade voltage detectors. They are designed with IP67 dust/water resistant and can withstand 2 meters drop. These durable devices are great for working in harsh environments. UT12E-EU has an optional vibration mode and UT12M-EU is able to detect magnetic fields.

Feature

Certifications: CE, UKCA, CETLUS

  • Auto power off

  • Buzzer

  • LED indication

  • IP 67

  • AC voltagedetection

  • High/Lowvoltage mode

  • Magnetic solenoiddetection (UT12M-EU)

  • Vibration mode(UT12E-EU)

Specifications

image.png

image.png

How does an AC voltage detector pen tester work?

The primary function of these detectors is to detect the presence of alternating current (AC) voltage and alert the user through visual and auditory signals. Detectors with the HLX vibration mode also feature haptic feedback, allowing for clear perception of voltage presence even in noisy environments.

  • Probe Contact: When the detector's probe comes into contact with electrical wires or equipment, the internal sensing elements (such as a sensing coil) detect changes in the AC electric field.

  • Signal Amplification: The detected weak electrical signal is amplified by the internal amplification circuit.

  • Threshold Detection: The amplified signal is compared with a preset threshold, and an alarm is triggered only if the signal strength exceeds the threshold.

  • Alarm Output: Once voltage exceeding the threshold is detected, the detector alerts the user through LED lights, beeping sounds, and vibration feedback.


Know your supplier
Wone
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
Analysis of Partial Discharge Principle (1)
Analysis of Partial Discharge Principle (1)
Analysis of Partial Discharge Principle (1)Under the action of an electric field, in an insulation system, discharge occurs only in some regions and does not penetrate between the conductors with the applied voltage. This phenomenon is called partial discharge. If partial discharge occurs near a conductor surrounded by gas, it can also be called corona.Partial discharge can occur not only at the edge of a conductor but also on the surface or inside an insulator. The discharge occurring on the su
Leon
07/19/2025
What types of FACTS controllers are there?
What types of FACTS controllers are there?
According to the type of connection FACTS Controller with the power system, it is classified as;Series Connected ControllerShunt Connected ControllerCombined Series-Series ControllerCombined Shunt-Series ControllerSeries-Connected ControllersSeries controllers introduce a voltage in series with the line voltage, typically using capacitive or inductive impedance devices. Their primary function is to supply or absorb variable reactive power as needed.When a transmission line is heavily loaded, the
Edwiin
07/19/2025
What are FACTS and related technologies?
What are FACTS and related technologies?
FACTS (Flexible Alternating Current Transmission System) refers to a power electronics-based system that uses static devices to enhance the power transfer capability and controllability of AC transmission networks.These power electronic devices are integrated into conventional AC grids to boost key performance metrics, including:Power transfer capacity of transmission linesVoltage stability and transient stabilityVoltage regulation precisionSystem reliabilityThermal limits of transmission infras
Edwiin
07/19/2025
What are the differences between HVAC and HVDC?
What are the differences between HVAC and HVDC?
Difference Between HVAC and HVDCElectricity generated in power plants is transmitted over long distances to electrical substations, which then distribute it to consumers. The voltage used for long-distance power transmission is extremely high, and we will explore the reasons for this high voltage later. Additionally, the transmitted power can be in either alternating current (AC) or direct current (DC) form. Therefore, power can be transmitted using either HVAC (High Voltage Alternating Current)
Edwiin
07/19/2025
What are the Advantages of HVDC over HVAC?
What are the Advantages of HVDC over HVAC?
What are the Advantages of HVDC over HVAC?Electricity travels long distances before reaching consumers. Power plants, often remote, supply electricity through hundreds of miles and multiple substations. High-voltage transmission reduces line losses, with both AC and DC used. Though AC is familiar via utility poles and home outlets, HVDC offers unique advantages in power transmission.The goal of power transmission is to minimize losses and costs. While both face influencing factors, HVDC has more
Edwiin
07/19/2025
Is the neutral - point grounding method of the power grid of 110kV and above only the neutral - point direct grounding method?
Is the neutral - point grounding method of the power grid of 110kV and above only the neutral - point direct grounding method?
Neutral - Point Grounding Modes and Protection of Transformers in Power GridsFor systems ranging from 110 kV to 500 kV, an effective grounding method shall be adopted. Specifically, under all operating conditions, the ratio of zero - sequence reactance to positive - sequence reactance X0/X1 of the system should be a positive value and not exceed 3. Meanwhile, the ratio of zero - sequence resistance to positive - sequence reactance R0/X1should also be a positive value and not exceed 1.In 330 kV a
Leon
07/19/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!