Search


Customization 27kV 33kV 33.5kV 34.5kV 35kV Outdoor High - Voltage Vacuum Three-phase recloser/reclosure

  • Customization 27kV 33kV 33.5kV 34.5kV 35kV Outdoor High - Voltage Vacuum Three-phase recloser/reclosure

Key attributes

Brand ROCKWILL
Series RCW
Rated voltage 27kV
Rated normal current 1250A
Rated peak value withstand current 31.5kA
Rated lightning impulse voltage 150kV
Description

Description:

Pioneer in China’s recloser industry and the first source manufacturer dedicated to this field — this is our identity forged by decades of deep cultivation. Over the past decades, we have consolidated our development foundation through technological breakthroughs, led the industry direction by formulating standards, and successfully built a fully independent system covering core technology R&D, large-scale mass production and delivery.

The RCW series automatic circuit reclosers are designed for use in overhead distribution lines and distribution substations. They are compatible with power systems operating at 50/60Hz, covering voltage classes from 11kV to 38kV. With a rated current capacity of up to 1250A, these reclosers integrate multiple functions, including control, protection, measurement, communication, fault detection, and real - time monitoring of closing and opening operations. Composed of an integration terminal, current transformer, permanent magnetic actuator, and a dedicated recloser controller, the RCW series vacuum reclosers offer a comprehensive solution for power distribution network management.

Features:

  • Flexible Current Ratings: Optional ratings within the rated current range to suit diverse application needs.

  • Customizable Protection: A variety of optional relay protection and logic schemes for users to choose from, ensuring adaptability to different system requirements.

  • Versatile Communication: Optional communication protocols and I/O ports available, enabling seamless integration with various monitoring and control systems.

  • User - Friendly Software: Equipped with PC software that supports controller testing, setup, programming, and updates, simplifying operation and maintenance.

Parameters:

The voltage classes of some of these Automatic Reclosers include 6kV, 6.3kV, 6.6kV, 6.9kV, 7.2kV, 10kV, 10.5kV, 11kV, 11.5kV, 12kV, 13.2kV, 13.8kV, 14.5kV, 14.4kV, 15kV, 15.5kV, 15.6kV, 17.5kV, 20kV, 21.9kV, 22kV, 24kV, 30kV, 33kV, 33.5kV, 34.5kV, 35kV, 36kV, 38kV, 38.5kV, 40.5kV, 44kV, 45kV, 46kV, 66kV and 69kV. Rated Short-Circuit Breaking Current includes 8kA, 12.5kA, 16kA, 20kA, 25kA, 31.5kA and customization is available.

Item

Specification

Rated maximum voltage

27kV

Rated maximum current

1250A

Rated frequency

50Hz

Rated short circuit breaking current

12.5kA

Rated peak value withstand current

31.5kA

Rated 1min power frequency withstand voltage (Three-phase Silicone rubber pole (unable the gas))

70kV

Rated lightning impulse voltage (Three-phase Silicone rubber pole (unable the gas))

150kV

Operation sequence

C-0.5-CO-2-CO-5-CO (Magnetic actuator)

Mechanical life

n:30000 (Magnetic actuator)

Power supply and operating voltage

110/220V (Customized)

Ratio of current transformer

400/1A (Customized)

Number of voltage sensors (Three-phase Silicone rubber pole (unable the gas))

≤3

Opening time

≤30ms (Magnetic actuator)

Closing time

≤40ms (Magnetic actuator)

Minimum creepage distance

31, level4 (mm/kV)

Minimum distance between phases

380mm

Potential transformer

110/220V (Customized)

Cable length

6,8,12m (Customized)

Cable clamp (Three-phase Silicone rubber pole (unable the gas))

2-hole NEMA

Lightning arrester

≤6

Mounting type

Single / double column

With optional relay protection & logics for user choice

Instantaneous over-current protection

Timing over-current protection

Negative sequence over-current protection

Directional over-current protection(⁽¹⁾)

Over-voltage protection / Under voltage protection

Programmable protection relay curves (total 10 nos ANSI/IEC curves)

Cold load pickup protection TCC + Hot line tag

Earth protection E/F SEF + Zone- Sequence Co-ordination

More relay functions can be customized

With optional communication protocols & I/O port for user choice

RS-232 and RS-485 ports supporting

DNP3.0 communication protocol support

Modbus communication protocol is optional

IEC 60870-501 communication protocol support

IEC 60870-5-104 communication protocol support

The recloser can communicate through GPRS(or) GSM(or) GPRS/GSM module with English or Specified language

With optional functions for use

Rated currents, System phase current,

Rated voltages, System phase voltage and secondary low voltage power supply voltage Frequency

power (kWh), reactive power (kVarh), power factor

With optional reclosing interval for user pre-program

reclosing times setting support

Dead time setting support

With events recording function

SOE 10000 operations record

Fault record and normal operation record

Note:mean should customized by manufacturer if needed

External dimensions:

企业微信截图_17103058136732.png

Environmental requirement:

Maximum temperature:

+40°C

Minimum temperature:

-30°C

Monthly average humidity

95%

Humidity:

90%

Above sea level:

2500m or higher

Ambient air Not apparently polluted by corrosive and flammable gas, vapor


 What are the key points for the selection of outdoor vacuum reclosers?

  • System Parameter Matching: Choose a recloser that matches the rated voltage, rated current, and short-circuit current levels of the power system. Ensure that the rated voltage of the recloser is equal to or higher than the system voltage, the rated current meets the requirements of the line load current, and the rated short-circuit breaking and making currents are greater than the maximum possible short-circuit current in the system.

  • Reclosing Performance Requirements: Consider the specific requirements of the power system for the reclosing function, such as the number of reclosures, reclosing time intervals, and reclosing success rate. Based on different application scenarios and power supply reliability requirements, select a recloser with appropriate reclosing performance. For example, for critical power supply lines, a recloser with a higher number of reclosures and flexible reclosing time intervals may be required.

  • Type of Operating Mechanism: Choose an appropriate operating mechanism based on actual needs. Spring-operated mechanisms are suitable for outdoor environments where high reliability is required and maintenance conditions are relatively poor. Permanent magnet-operated mechanisms are better suited for applications requiring high action speed and frequent operations.

  • Environmental Adaptability: Given the harsh conditions of outdoor environments, consider the environmental adaptability of the recloser. This includes weather resistance, pollution resistance, and water and dustproof performance. Selecting a recloser with good environmental adaptability ensures stable performance during long-term outdoor operation.

  • Brand and Quality: Choose well-known brands and high-quality recloser products. These products have strict quality control systems in design, manufacturing, and testing, ensuring the performance and reliability of the product. Additionally, good after-sales service is an important factor to consider when choosing a brand, as it ensures timely resolution of issues that may arise during equipment operation.


Solutions - Vacuum recloser

Case Studies - Vacuum recloser

  • Successful Case of 263 Units of 33kV Oil-immersed 32-step Voltage Regulator Controller Project in Bangladesh
    Successful Case of 263 Units of 33kV Oil-immersed 32-step Voltage Regulator Controller Project in Bangladesh01 Overall Project Overview1.1 Project BackgroundIn June 2024, 263 units of 33kV oil-immersed 32-step voltage regulator controller were officially delivered and applied to the Bangladesh Medium Voltage Distribution Network Upgrade Project. R&D and manufactured by Rockwill, these devices are used for voltage stability regulation, load fluctuation adaptation and power supply quality impr
  • DTEK Grid Upgrade: Operation of Rockwill 10kV Smart Recloser in -40°C Extreme Cold Environment Ukraine Case Study
    As a benchmark for Chinese‑manufactured medium‑voltage distribution equipment going global, Rockwill established in‑depth cooperation with DTEK Kyiv Power Grid, Ukraine. Tailored outdoor vacuum recloser solutions were mass‑deployed to address existing weaknesses in local 10 kV distribution networks, comprehensively improving regional power supply reliability and automation to build a flagship distribution grid modernization project in Kyiv.01 Project Background: Core Pain Points of DTEK Kyiv Dis
  • Rockwill Ukraine 186 Units 12kV Outdoor Vacuum Recloser Project Success Case
    In response to the operational characteristics of Ukraine’s local power grid and targeting harsh high-latitude outdoor working conditions, we rely on core technologies of intelligent reclosing and self-healing to precisely adapt to the complex grid environment with frequent thunderstorms and drastic diurnal temperature variations, steadily promoting the automatic and intelligent upgrade of regional rural power grids and suburban distribution networks.01 Project Overview1.1 Project BackgroundIn 2
  • Successful Case of 170 Sets of 11kV Automatic Recloser Project in Kenya
    Against the backdrop of quality upgrading for Kenya’s urban and rural power grids, 11kV auto-reclosers deliver reliable performance to suit local climates and grid conditions. It enables rapid fault isolation and efficient operation and maintenance, forming a core safeguard for the upgrading of Kenya’s urban and rural distribution networks.01 Project Overview1.1 Project BackgroundIn May 2023, 170 sets of 11kV Automatic Reclosers (Model: RCW12M) were officially supplied and applied to the medium-

Related Blogs - Vacuum recloser

  • Industry Analysis: Medium-Voltage Automatic Reclosers — The 0.5A–16,000A Full-Range Protection Capability That Redefines
    1. What Makes a Recloser Truly World-Class? Starting from the "0.5A–16,000A" Range Ratio The global pole-mounted automatic recloser market is undergoing a paradigm shift from "protective switches" to "intelligent distribution nodes." With distributed energy resources connecting to distribution grids at scale, bidirectional power flow and high-impedance fault detection demands are becoming increasingly prominent. Grid operators now impose stringent requirements on a recloser's ability to precisel
  • Rockwill RCW Series Automatic Circuit Reclosers: World-Class Technology & Global Track Record
    The Rockwill RCW Series Automatic Circuit Reclosers are intelligent Automatic Circuit Reclosers (ACR) fully compliant with both IEC 62271-111 and ANSI/IEEE C37.60 international standards, covering the full voltage range from 11kV to 38kV for 50/60Hz power systems. As a pioneer in China's recloser sector and a leading medium-to-high voltage power equipment original manufacturer, Rockwill serves over 100 countries worldwide, offering a Chinese-origin solution that competes head-to-head with intern

Documentation Resource Library Vacuum recloser

Public
27kV automatic recloser technology specification 27kV automatic recloser technology specification
Technical Data
English
Restricted
10 to 38kV auto vacuum break recloser Catalog 10 to 38kV auto vacuum break recloser Catalog
Catalogue
English
PDF
Restricted
15kV/27kV/38kV outdoor auto break vacuum recloser 15kV/27kV/38kV outdoor auto break vacuum recloser
Brochure
English
PDF
Restricted
Specification for 33kV Vacuum Automatic Recloser by Kenya Power and Lighting Company Limited (KPLC) Specification for 33kV Vacuum Automatic Recloser by Kenya Power and Lighting Company Limited (KPLC)
Others
English
PDF
Restricted
SEC SPECIFICATIONS FOR SMART MV AUTO-RECLOSER SEC SPECIFICATIONS FOR SMART MV AUTO-RECLOSER
Others
English
PDF
Public
DEKRA Recloser Test Report DEKRA Recloser Test Report
Test Report
English
Public
RCW-E38M/1250-20 MV Outdoor Vacuum Recloser RCW-E38M/1250-20 MV Outdoor Vacuum Recloser
Drawings
English

Frequently asked questions

Yes. The RCWP, a cost-optimized option in the RCW+ series, features dual sensors, flagship controller, and 30,000 operations with permanent magnet three-phase linkage, while offering downgrade options (lock box removal, lockout removal, sensor/controller downgrade) so customers pay only for what they need.

Yes. Rockwill vacuum recloser stands behind the RCW series with one of the most comprehensive warranties in the recloser industry: a full 10-year warranty covering the complete recloser, including the vacuum interrupter, permanent magnet operating mechanism, and control electronics.

Any failure resulting from material or manufacturing defects during the warranty period is eligible for free replacement. Our warranty terms are straightforward and transparent, with no hidden conditions or complex exclusions, giving you complete peace of mind.

The ZW32-type VCB is a basic circuit breaker or demarcation switch without built-in auto-reclosing logic, whereas the  RCW vacuum recloser is specifically engineered as a full-function recloser with integrated protection, sensors, and communication for smart grid applications.

Unlike the ZW32, which requires an external controller for automation, the RCW series complies with IEC 62271-111 and ANSI C37.60, and is supported by complete type test reports.With silicone rubber or epoxy insulation offering superior aging resistance and low water absorption, the RCW series is the professional choice for international distribution automation projects.

Yes. The solid-dielectric design is maintenance-friendly and suited to outdoor pole mounting. It supports single or double column mounting, making it suitable for pole mounted recloser projects.

The compact structure and lightweight design also help reduce installation time and on-site labor costs. If you are upgrading an existing overhead line, the RCW series can usually be integrated without major structural changes.

Our team provides technical support for controller setup, protection configuration, communication debugging, and after-sales service. Please contact us with your project details, and we will recommend a suitable recloser solution.

Support includes PC software operation, parameter setting, communication testing, and troubleshooting guidance. This helps customers complete commissioning faster and reduce downtime.

The Rockwill standard smart recloser offers high precision with a wide measuring range (2A–16,000A). Simply ensure your normal current is within this standard range when making a selection.

Yes. In addition to the standard 2A–16,000A range, Rockwill provides custom-configured units for ultra-low current measurement and protection in the 0.1A–2A range.

Know your supplier

Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m² Total staff: 700+ Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: Medium and High Voltage Switchgear/Power and Distribution Transformers/Instrument Transformers and Sensors/Lightning Protection and Electrical Insulation/Substations and E-Houses/Electrical Panel and Controlgear
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.
Login
or continue with
New here?
Register