• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


semiconductor fuse link aR fuse DNT-J1L series

  • semiconductor fuse link aR fuse DNT-J1L series
  • semiconductor fuse link aR fuse DNT-J1L series
  • semiconductor fuse link aR fuse DNT-J1L series

Key attributes

Brand Switchgear parts
Model NO. semiconductor fuse link aR fuse DNT-J1L series
Rated voltage AC690V
Rated normal current 800-1600A
Breaking capacity 100kA
Series DNT-J1L

Product descriptions from the supplier

Description

What is a semiconductor fuse?

A semiconductor fuse, also known as a high-speed fuse or a fast-acting fuse, is a specialized type of electrical fuse designed to protect sensitive semiconductor devices from overcurrent conditions. These fuses are engineered to quickly interrupt the flow of current in a circuit when a fault or overcurrent event occurs.

Here are some key characteristics and features of semiconductor fuses:

1.Fast Response Time: Semiconductor fuses are designed to react very quickly to overcurrent events. This rapid response helps protect semiconductor devices that may be sensitive to short-duration, high-current spikes.

2.Specific Current Ratings: Semiconductor fuses are rated based on their current-carrying capacity. It’s crucial to select a fuse with a current rating that matches or slightly exceeds the nominal operating current of the protected semiconductor device.

3.Voltage Ratings: The voltage rating of the fuse should be equal to or greater than the voltage of the circuit it is protecting. Using a fuse with a lower voltage rating can lead to unreliable protection.

4.Application-Specific: Semiconductor fuses are commonly used in circuits containing sensitive electronic components like diodes, transistors, thyristors, and other semiconductor devices.

5.Construction: They are typically constructed with specialized materials and designs to handle the unique characteristics of semiconductor applications.

6.Coordination with Other Protection Devices: Semiconductor fuses are often used in conjunction with other protective devices like circuit breakers to provide comprehensive protection for an electrical system.

7.Standards and Compliance: Semiconductor fuses are subject to industry standards and certifications. Ensuring that the chosen fuse complies with relevant standards is essential for safety and performance.

8.Safety and Reliability: Proper selection and application of semiconductor fuses are crucial for the safe and reliable operation of electronic and electrical systems.

Semiconductor fuses play a critical role in safeguarding semiconductor devices from potentially damaging overcurrent conditions. Choosing the right fuse, based on factors like current ratings, voltage ratings, and response time, is essential for effective protection. Consulting with a qualified electrical engineer or expert in the field is recommended for proper selection and installation of semiconductor fuses.

 

Semiconductor fuses find application in a variety of industries and environments where sensitive electronic components need protection from overcurrent conditions.

Here are some common application areas for semiconductor fuses:

Industrial Automation: Semiconductor fuses are used in automation systems where sensitive electronic control circuits, such as PLCs (Programmable Logic Controllers), are employed. They protect these critical components from overcurrent events that could lead to damage or malfunction.

Power Electronics: In power electronics applications, semiconductor devices like diodes, thyristors, IGBTs (Insulated Gate Bipolar Transistors), and MOSFETs (Metal-Oxide-Semiconductor Field-Effect Transistors) are used. Semiconductor fuses are crucial to safeguard these devices from short-circuit and overcurrent conditions.

Telecommunications: They are used in telecommunications equipment to protect sensitive electronic components like transistors, diodes, and integrated circuits from electrical faults.

Renewable Energy Systems: Semiconductor fuses are employed in solar inverters, wind turbine converters, and other renewable energy systems to protect the sensitive electronics from overcurrent events.

Medical Equipment: Sensitive electronic components are present in various medical devices, and semiconductor fuses are used to ensure their protection from overcurrent conditions.

Electrical Distribution Systems: In large electrical distribution systems, semiconductor fuses can be used to protect critical electronic components in switchgear, control panels, and power distribution boards.

Automotive Electronics: Modern vehicles rely on a wide range of electronic systems. Semiconductor fuses play a role in protecting these electronic components from overcurrent events.

Consumer Electronics: Semiconductor fuses can be found in various consumer electronics devices like televisions, audio equipment, and computer systems, where sensitive semiconductor devices are used.

Regarding semiconductor devices themselves, they are a crucial component of modern electronics. Semiconductors are materials with electrical properties that lie between those of conductors (like metals) and insulators (like ceramics). They have the ability to conduct electrical current under certain conditions, and their conductivity can be controlled or modulated.

Common semiconductor materials include silicon, gallium arsenide, and other compounds. Semiconductors are used in a wide range of electronic devices, including transistors, diodes, integrated circuits, and more. They form the backbone of modern electronics and are found in applications ranging from microchips in computers to power devices in electrical systems.

Basic parameters of fuse links

Product model size Rated voltage          V Rated current         A Rated breaking  capacity    kA
DNT1-J1L-100 1 AC 690 100 100
DNT1-J1L-125 125
DNT1-J1L-160 160
DNT1-J1L-200 200
DNT1-J1L-250 250
DNT1-J1L-315 315
DNT1-J1L-350 350
DNT1-J1L-400 400
DNT1-J1L-450 450
DNT1-J1L-500 500
DNT1-J1L-550 550
DNT1-J1L-630 630
DNT2-J1L-350 2 350
DNT2-J1L-400 400
DNT2-J1L-450 450
DNT2-J1L-500 500
DNT2-J1L-550 550
DNT2-J1L-630 630
DNT2-J1L-710 710
DNT2-J1L-800 800
DNT2-J1L-900 900
DNT2-J1L-1000 1000
DNT2-J1L-1100 1100
DNT2-J1L-1250 1250
DNT3-J1L-800 3 800
DNT3-J1L-900 900
DNT3-J1L-1000 1000
DNT3-J1L-11003 1100
DNT3-J1L-1250 1250
DNT3-J1L-1400 1400
DNT3-J1L-1500 1500
DNT3-J1L-1600* 1600
Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Low Voltage Electrical Apparatus/Instrument meters/Production equipment/Tester/High Voltage Electrical Apparatus/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding Electrodes
    Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding ElectrodesWhen the grounding electrode of an Ultra-High-Voltage Direct Current (UHVDC) transmission system is located close to a renewable energy power station, the return current flowing through the earth can cause a rise in ground potential around the electrode area. This ground potential rise leads to a shift in the neutral-point potential of nearby power transformers, inducing DC bias (or DC offset) in their
    01/15/2026
  • HECI GCB for Generators – Fast SF6 Circuit Breaker
    1.Definition and Function1.1 Role of the Generator Circuit BreakerThe Generator Circuit Breaker (GCB) is a controllable disconnect point located between the generator and the step-up transformer, serving as an interface between the generator and the power grid. Its primary functions include isolating generator-side faults and enabling operational control during generator synchronization and grid connection. The operating principle of a GCB is not significantly different from that of a standard c
    01/06/2026
  • Distribution Equipment Transformer Testing, Inspection, and Maintenance
    1.Transformer Maintenance and Inspection Open the low-voltage (LV) circuit breaker of the transformer under maintenance, remove the control power fuse, and hang a “Do Not Close” warning sign on the switch handle. Open the high-voltage (HV) circuit breaker of the transformer under maintenance, close the grounding switch, fully discharge the transformer, lock the HV switchgear, and hang a “Do Not Close” warning sign on the switch handle. For dry-type transformer maintenance: first clean the porcel
    12/25/2025
  • How to Test Insulation Resistance of Distribution Transformers
    In practical work, insulation resistance of distribution transformers is generally measured twice: the insulation resistance between thehigh-voltage (HV) windingand thelow-voltage (LV) winding plus the transformer tank, and the insulation resistance between theLV windingand theHV winding plus the transformer tank.If both measurements yield acceptable values, it indicates that the insulation among the HV winding, LV winding, and transformer tank is qualified. If either measurement fails, pairwise
    12/25/2025
  • Design Principles for Pole-Mounted Distribution Transformers
    Design Principles for Pole-Mounted Distribution Transformers(1) Location and Layout PrinciplesPole-mounted transformer platforms should be located near the load center or close to critical loads, following the principle of “small capacity, multiple locations” to facilitate equipment replacement and maintenance. For residential power supply, three-phase transformers may be installed nearby based on current demand and future growth projections.(2) Capacity Selection for Three-Phase Pole-Mounted Tr
    12/25/2025
  • Transformer Noise Control Solutions for Different Installations
    1.Noise Mitigation for Ground-Level Independent Transformer RoomsMitigation Strategy:First, conduct a power-off inspection and maintenance of the transformer, including replacing aged insulating oil, checking and tightening all fasteners, and cleaning dust from the unit.Second, reinforce the transformer foundation or install vibration isolation devices—such as rubber pads or spring isolators—selected based on the severity of vibration.Finally, strengthen sound insulation at weak points of the ro
    12/25/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file

IEE Business will not sell or share your personal information.

Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.