Regulator Bypass Switch na IEE-Business

  • Regulator Bypass Switch

Abubuwa gaba

Muhimmiya ROCKWILL
Model NO. Regulator Bypass Switch na IEE-Business
Rated Voltage 38kV
Raitidu kọ̀ọ̀kan 600A
Siri BPR

Bayani na sayen daga mai wuyaci

Sharararwa

An BPRS Station Class Regulator Bypass Switch na gaji ɗaya da tsohon kofin maimakon aiki da voltage regulators. An yi BPRS don amfani da shi a cikin station class voltage regulators da zai iya set su a neutral. BPRS ya fi yawa, an sauya ta musamman saboda ba za a iya gaji abu mai girma game da operator, kuma an amfani da wani interrupter da ake amfani a AR Switches muna samun excitation current ba a tabbata tsakanin. Yana da tsari mai yawa, saboda haka ana bukatar da ake sa shi a cikin sabbin source/load configuration. BPRS an amfani ESP Enhanced Silicone Polymer a matsayin yanayin masu jirgin ruwa mafi inganci. Tana da tasiri mai kyau 600A da 1200A, kuma za a iya bayarwa a 15kV 150kV, 29/38kV 200kV BIL. BPRS ya samu wannan station class insulation levels tare da amfani TR rated 3" BC porcelain insulator don bayar da leakage to ground. Base ce da ke M3S disconnects, kuma yana da kyau don amfani a cikin steel structures. Chance: Brand da Quality da Zan Yi Fara!!

  • Fully Compliant with ANSI/IEEE C37.30.1

  • For Station Class Regulator Bypass Applications

  • Designed for use with Regulators that can be set on Neutral

  • Single Pull Sequenced Operation

  • 15 & 27/38kV Voltage Classes

  • 150 & 200kV BIL Insulation Levels

  • 600A and 1200A Current Ratings

  • TR Rated Post Insulator to provide standoff for most substation requirements

  • Utilizes the Interrupter on our AR Automation Ready Gang Operated Switches

  • Station Base for Structure mounting

Designed for Applications

Daga rarrabe, BPR Regulator Bypass switch ya gaji ɗaya da tsohon kofin maimakon aiki da kuma bayyana distribution ko substation voltage regulator don jimla. An yi shi don amfani da duka voltage regulators da zai iya set su a neutral don switching operation. Wannan ya haɓaka duka single da three phase regulators, ba three-phase induction regulators ba.

BPR Switch an sauya ta musamman don bayyana voltage regulator a cikin ɗaya da tsohon kofin maimakon aiki, ba a tafara aiki na system ba. Ya ni, voltage regulator ya bayyana a cikin tsari mai yawa ba a tabbata abubuwa na operator.

Parameters

Maimakanta mai inganci
Kayan da ke zuwa
kima mai yiwuwa da wata
Waktu na kirma
100.0%
≤4h
Gaskiya ta hanyar kamfanin
Workplace: 108000m²m² Jami'a nanan mafi girma: 700+ Zama-zama na Farko da aka Fitowa a Shekarar (USD): 150000000
Workplace: 108000m²m²
Jami'a nanan mafi girma: 700+
Zama-zama na Farko da aka Fitowa a Shekarar (USD): 150000000
Aiki
Turanci Masana: Design/Manufakturi/Sallar
Ƙananunan Cigaba: Gwọ́n ọkụ̀ àbálòpà/Transformator
Mafarkin tsoro na yawan kulle
Kayan aiki na alaka da amfani, yin amfani, gyara-gyaran da kuma pasuwa na kayan karkashin yanayi, suka kentuwa da kaiwansu masu iko, ingantacciyar hankali da kuma amfani mai kyau.
mabudin aikatan kayan dabbobi sun dawo da idoni masu iko da ma'ajiriyya, sannan suka tabbata inganci, kwayoyin uku da na'ibbicci ne daga babban kayan aikin

Makarantar Mai Yawanci

Zan'antar Ilimi

  • Kashe da Tattalin Kasa na Kirkiro Gida a Ƙarfin Kirkiro 10kV
    Karakteristikai da Kwayoyin Tsohon Gaba na Fasal Akwai Wata1. Karakteristikai na Fasal Akwai WataSignaolin Alarami na Wasu:Bello na alarami ya kara, kuma lampan na bayani "Fasal Akwai Wata a [X] kV Bus Section [Y]" ta kafa. A cikin sistemai da ke amfani da Petersen coil (coil na paka wata) don kare gaba na neutral point, lampan na "Petersen Coil Operated" kuma ta kafa.Bayanin Voltmeter na Paka Insulation:Tushe na fasal akwai wata ta zama yawa (a lokacin da ke tsakanin paka mai yawa) ko ta daga z
    01/30/2026
  • Gidamintar da take gudanar da shi a wurin karkashin 110kV~220kV na IEE-Business
    Na gaba da hanyar kan zabe ta rike masu shirya na 110kV~220kV, yana bukata cewa zabe ta rike masu shirya na tsakiyar karamin sauti suka dace da muhimmanci, kuma yana bukata cewa zabe ta rike masu shirya na tsakiyar karamin sauti suke musamman. Kuma yana bukata cewa zabe ta rike masu shirya na tsakiyar karamin sauti ba suka fi yawa da tare da uku da zabe ta rike masu shirya na tsakiyar karamin sauti.Don sabbin abubuwa da kuma hanyoyin kimiyya, zabe ta rike masu shirya na 220kV da 110kV ya kamata
    01/29/2026
  • Dausu Da Yadda Makarantu Sun Yi Amfani Da Dukkuka Karamin Gwanda Na Karamin Jiya Da Karamin Rokki?
    Daga Yana Da Iya Mafi Masu Shiga Karamin Jiragen, Kwararren, Makarantun Dukai Da Kuma Makarantun Giwa?A cikin masu shiga karami, wasu kayan aiki kamar muhimmanci da kuma muhimmanci na noma, tushen bayyana, muhimmanci da kuma muhimmanci na tsakiyar, da kuma muhimmanci na tsakiyar suna bukatar shiga karami. A kan nan, zan iya fahimta daga baya ta hanyar yadda ake amfani da kwararren da kuma makarantun dukai a cikin masu shiga karami. Ba saboda haka, wannan kwararre ya taka rawa masu dalilai da kum
    01/29/2026
  • Yadda ya zama da kyau a kan gwamnati na tsaro kawai tafi daga baya? Ba a tabbas cewa a kan gwamnati na tsaro kawai tafi daga mafi girma?
    Daga cewa Mafi yadda Annabiya na Transformer Daidai Don?A lokacin da transformer ya yi aiki, mafi yadda, tare da kaya, abincin da kuma muhimman da suka da amfani don bincike mafi yadda da windings, suna cikin elektrik field mai girma. A kan takarda wannan elektrik field, suka samu potential mai ukuwa da ground. Idan mafi yadda ba da ground, za a cikin mafi yadda da kaya da tank, zai kasance potential difference wanda zai iya haifar da discharge mai yawa.Kuma, a lokacin da transformer ya yi aiki,
    01/29/2026
  • Fahimtar Tashin Gine na Tashin Kawo Masu Zafi
    I. Maimaita Neutral Point?A cikin transforma da kuma maimaitarai, maimaita neutral point shine maimaitar tana da aiki a kan yawan winding inda tsari mai zurfi daga wannan maimaitar zuwa har daidai na terminal sama da duka. A cikin diagrammin da ake bayar, maimaita O yana nufin maimaita neutral point.II. Yadda Ake Iya Sabon Duka Don Maimaita Neutral Point?Sauran hanyoyi na elektrik da take sabon duka don maimaita neutral point da kasa a cikin systemin AC three-phase yana nufin sabon dukar neutral
    01/29/2026
  • Me kuke so kuɗi a wasu Rectifier Transformers da Power Transformers?
    Mai shi ne mai Transformer na Rectifier?"Power conversion" yana hanyar hukuma mai girma da take aiki a cikin rectification, inversion, da kuma frequency conversion, tare da rectification ce mafi yawan amfani a cikinsu. Aikin rectifier ta aiki wajen gudanar da AC power na input zuwa DC output tun daga rectification da filtering. Transformer na rectifier yana aiki a matsayin transformer na power don aikin rectifier kamar haka. A cikin amfani na takamakawa, akwai karin DC power supplies suka samun
    01/29/2026

Halayyar Bubuwa

  • Koƙari na Ƙaunsi 24kV na Tana Iya Mai Tsabta Daji
    A cikin ɗaya da take da Solid Insulation Assist + Dry Air Insulation yana nuna hanyar zama na RMUs na 24kV. Ta haka, tana iya kula da al'amuran insulation da kuma gudummawa, ta haka za a iya tabbatar da ci gaba da insulation tests ba zan iya karfin ƙarin inganci daga phase-to-phase da phase-to-ground. An fi pole column fitowa don samun insulation masu vacuum interrupter da connecting conductors.Tare da ƙarfin ɗaya da take da 24kV outgoing busbar phase spacing a 110mm, za a iya kula da electric f
    08/16/2025
  • Gwadabuwar Takardunawa na 12kV Air-Insulated Ring Main Unit Isolating Gap don Kudin Iya Gwadabuwar Discharge
    Nun da industriya na kashi ta gudana da yawa, an yi amfani da misaloli na karfi, kadan ciki, da hankali ga al'adu a wajen gwargwadon kayan abokan kashi da kuma kayan abokin kashi. Ring Main Unit (RMU) shi ne wuri mai mahimmanci a tashar kayan abokan kashi. Hukuma, hankali ga al'adu, ingancin aiki, kadan ciki, da kuma tattalin arziki suna da muhimmanci a cikin tushen. RMUs na gargajiya sun hada da RMUs mai gas SF6. Saboda ingancin aiki na SF6 da kuma ƙarfinsa mai ƙarin, ana amfani da su da yawa.
    08/16/2025
  • Analisis na Mafiya da Duk da a 10kV Gas-Insulated Ring Main Units (RMUs)
    Introduccio:​​Ie RMUs insulados con gas de 10kV son ampliamente utilizados debido a sus numerosas ventajas, como estar completamente cerrados, poseer un alto rendimiento de aislamiento, no requerir mantenimiento, tener un tamaño compacto y ofrecer una instalación flexible y conveniente. En esta etapa, han llegado a ser gradualmente un nodo crítico en la red de distribución urbana de alimentación en anillo y juegan un papel significativo en el sistema de distribución de energía. Los problemas den
    08/16/2025
Babu samun mai arliƙi daidai ba? Sai ma'arikin mai arliƙi gane kika. Samun Kwatanti Yanzu
Babu samun mai arliƙi daidai ba? Sai ma'arikin mai arliƙi gane kika.
Samun Kwatanti Yanzu
Aika tambaya
+86
Dauke kake saita fayil
Kwamfuta
Samun IEE Business Application
Yi amfani da IEE-Business app don samun abubuwan aikin, samun halayyin, haɗi da malamai, kuma kai tsauraran takaiddun kasoshin duka lokaci, duka wurin—dole bai karfin takamaltar hulɗin ku na alintakargida da kasuwanci.