12kV Indoor High Voltage Vacuum Circuit Breaker
discuss personally
Model
VDS4-12-3150
VDS4-12-2500
VDS4-12-2000
VDS4-12-1600
VDS4-12-1250
VDS4-12-630
Basic info
Brand ROCKWILL
Model NO. 12kV Indoor High Voltage Vacuum Circuit Breaker
Rated voltage 12kV
Rated normal current 3150A
Series VDS4
Product Detail

Product Introduction

The VDS4 series indoor high-voltage AC vacuum circuit breaker is designed for three-phase AC 50Hz power systems with a rated voltage ranging from 7.2 to 40.5kV. Widely applied in substations, power plants, industrial facilities, airports, and buildings, it excels at controlling and safeguarding electrical equipment. With its capabilities for frequent operations and rapid reclosing, it ensures reliable power management.

This breaker adheres to national standards, including GB/T 1984-2014 "High Voltage AC Circuit Breaker", JB/T 3855-2008 "High Voltage AC Vacuum Circuit Breaker", and DL/T 403-2000 "12kV~40.5kV Indoor AC High Voltage Vacuum Circuit Breaker Ordering Technical Requirements". It also complies with international regulations set by the International Electrotechnical Commission, such as IEC 62271-100, IEC 60694, and IEC 62271-1, guaranteeing quality and global compatibility.

Technical parameters

The following table details the key technical specifications of the product, comprehensively covering electrical performance, mechanical characteristics, and dimensional parameters to provide a clear reference for technical selection and application scenarios.

Features
The product offers multiple significant advantages, which can fully meet the diverse needs of industrial and power systems. Specifically included are:

  •  Excellent Electrical Performance of Fully Enclosed Pole

The main circuit of the VSV series vacuum circuit breaker adopts a fully enclosed structure, available in two types: insulated cylinder or solid pole.

  • Insulated Cylinder Structure:

The main electrical components are longitudinally installed in an epoxy resin cylinder cast via the APG process. This structure offers superior arc resistance, anti-aging properties, and high mechanical strength. It effectively shields the vacuum interrupter from external factors such as mechanical impacts and environmental pollution while enhancing the conductive circuit’s capability to withstand rated short-term (peak) withstand currents.

  • Sealed Pole Structure (P Series):

The miniaturized vacuum interrupter and other main circuit components are directly sealed in epoxy resin using advanced APG technology. This not only simplifies the pole assembly process and improves the reliability of the vacuum interrupter’s conductive circuit but also protects the interrupter’s outdoor surface from external mechanical forces and environmental influences.

  •  Corrosion-Resistant Mechanism with Advanced Design

Structural components undergo super anti-corrosion and anti-salt spray zinc-nickel alloy treatment.

Transmission parts are treated with high-hardness, wear-resistant, and corrosion-resistant nickel-phosphorus alloy.

International brand INA oil-free graphite bearings are used for transmission, ensuring high strength and excellent wear resistance.

  •  C2-Level Circuit Breaker Compliance

During capacitive current interruption, the breaker exhibits an extremely low probability of re-strike, fully meeting the requirements for C2-level circuit breakers.

  •  E2-Level Circuit Breaker Certification

The breaker has successfully passed all tests at the Shenyang High Voltage Electrical Appliance Research Institute and Xi’an High Voltage Electrical Appliance Research Institute testing centers. It complies with the E2-level standard, demonstrating:

  • 30 operations with full-rated short-circuit current for low-current breakers.

  • 20 operations with full-rated short-circuit current for high-current breakers.

 

 

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Analysis of Partial Discharge Principle (1)
Analysis of Partial Discharge Principle (1)
Analysis of Partial Discharge Principle (1)Under the action of an electric field, in an insulation system, discharge occurs only in some regions and does not penetrate between the conductors with the applied voltage. This phenomenon is called partial discharge. If partial discharge occurs near a conductor surrounded by gas, it can also be called corona.Partial discharge can occur not only at the edge of a conductor but also on the surface or inside an insulator. The discharge occurring on the su
Leon
07/19/2025
What types of FACTS controllers are there?
What types of FACTS controllers are there?
According to the type of connection FACTS Controller with the power system, it is classified as;Series Connected ControllerShunt Connected ControllerCombined Series-Series ControllerCombined Shunt-Series ControllerSeries-Connected ControllersSeries controllers introduce a voltage in series with the line voltage, typically using capacitive or inductive impedance devices. Their primary function is to supply or absorb variable reactive power as needed.When a transmission line is heavily loaded, the
Edwiin
07/19/2025
What are FACTS and related technologies?
What are FACTS and related technologies?
FACTS (Flexible Alternating Current Transmission System) refers to a power electronics-based system that uses static devices to enhance the power transfer capability and controllability of AC transmission networks.These power electronic devices are integrated into conventional AC grids to boost key performance metrics, including:Power transfer capacity of transmission linesVoltage stability and transient stabilityVoltage regulation precisionSystem reliabilityThermal limits of transmission infras
Edwiin
07/19/2025
What are the differences between HVAC and HVDC?
What are the differences between HVAC and HVDC?
Difference Between HVAC and HVDCElectricity generated in power plants is transmitted over long distances to electrical substations, which then distribute it to consumers. The voltage used for long-distance power transmission is extremely high, and we will explore the reasons for this high voltage later. Additionally, the transmitted power can be in either alternating current (AC) or direct current (DC) form. Therefore, power can be transmitted using either HVAC (High Voltage Alternating Current)
Edwiin
07/19/2025
What are the Advantages of HVDC over HVAC?
What are the Advantages of HVDC over HVAC?
What are the Advantages of HVDC over HVAC?Electricity travels long distances before reaching consumers. Power plants, often remote, supply electricity through hundreds of miles and multiple substations. High-voltage transmission reduces line losses, with both AC and DC used. Though AC is familiar via utility poles and home outlets, HVDC offers unique advantages in power transmission.The goal of power transmission is to minimize losses and costs. While both face influencing factors, HVDC has more
Edwiin
07/19/2025
Is the neutral - point grounding method of the power grid of 110kV and above only the neutral - point direct grounding method?
Is the neutral - point grounding method of the power grid of 110kV and above only the neutral - point direct grounding method?
Neutral - Point Grounding Modes and Protection of Transformers in Power GridsFor systems ranging from 110 kV to 500 kV, an effective grounding method shall be adopted. Specifically, under all operating conditions, the ratio of zero - sequence reactance to positive - sequence reactance X0/X1 of the system should be a positive value and not exceed 3. Meanwhile, the ratio of zero - sequence resistance to positive - sequence reactance R0/X1should also be a positive value and not exceed 1.In 330 kV a
Leon
07/19/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!