Primary SF6-Free Switchgear

Primary distribution switchgear with no SF6 in the tank — G3 clean gas, dry air and conditioned-air RMUs plus air-insulated primary panels, from 12kV to 40.5kV, built for zero-GWP networks.

GWP 0            No SF6, no F-gas accounting
12–40.5kV      Primary voltage range
630–1250A     Busbar ratings
20–31.5kA      Short-time withstand

Primary SF6-Free Switchgear

What primary SF6-free switchgear is

Primary SF6-free switchgear does the same job as a conventional primary SF6 ring main unit — receive, sectionalise and protect the feeders below a substation transformer — but replaces SF6 with a dielectric that has no global warming potential: G3 clean gas, dry air, conditioned air, or simply atmospheric air in air-insulated panels.

The switching medium does not change: sealed vacuum interrupters still break the current. Only the insulation changes, which is why an SF6-free board can carry the same 630–1250A and 20–31.5kA ratings as the SF6 unit it replaces.

The practical driver is regulatory and procurement, not performance. F-gas rules are progressively closing the market for new SF6 medium-voltage equipment, and utilities increasingly write "SF6-free" into tenders before the rules require it. Choosing the route early avoids redesigning the switch room later.

  • Dielectric optionsG3 clean gas · dry air · conditioned air · atmospheric air
  • Voltage classes12 / 24 / 36 / 33 / 35 / 40.5kV
  • Ratings630 / 1250A, 20 / 25 / 31.5kA
  • InterruptionSealed vacuum interrupter or VCB
  • GWP0 — no SF6, no F-gas reporting
  • StandardsIEC 62271-1, -100, -102 / -103, -200

 

SF6-free primary switchgear range

Three SF6-free routes, one voltage class. Each product links to its dedicated page with full specifications.

G3 clean-gas primary SF6-free switchgear

Primary Gas Insulated RMU — G3

Sealed G3 clean-gas primary RMU covering 12kV to 40.5kV in one tank family, near-zero GWP with no F-gas reporting.

  • Series: RMR / REC
  • Rated voltage: 12 / 24 / 33 / 40.5kV
  • Power-freq withstand: 28 / 50 / 70kV (by class)
  • Lightning impulse: 75 / 125 / 170kV (by class)
  • Busbar current: 630 / 1250A (up to 2000A)
  • Short-time withstand: 20 / 25kA, 3s
  • Insulation: G3 clean gas, SF6-free
  • Standard: IEC 62271-1, -102 / -103
View product →
 
Maintenance-Free G3 RMU 33/35/40.5kV

G3 clean-gas ring main unit for 33kV through 40.5kV primary distribution — sealed for life, no gas top-up.

  • Series: RMR
  • Rated voltage: 33 / 35 / 40.5kV
  • Power-freq withstand: 70 / 80 / 95kV
  • Lightning impulse: 170 / 185 / 250kV
  • Frequency: 50 / 60Hz
  • Insulation: G3 clean gas, maintenance-free
View product →
 
Eco-Friendly Gas-Insulated RMU 12kV

REC-series eco-friendly gas-insulated RMU for 12kV distribution, 1250A busbar with SF6-free insulation.

  • Series: REC
  • Rated voltage: 12kV
  • Rated normal current: 1250A
  • Frequency: 50 / 60Hz
  • Insulation: Eco-friendly gas, SF6-free
View product →
Primary SF6-Free Switchgear

Dry air and pure-air SF6-free RMU

Dry Air RMU 12–40.5kV

Dry-air insulated RMU integrating LBS, VCB, earthing switches, CT/VT and protection relays in a sealed assembly, with IEC 61850 / DNP3 communication.

  • Rated voltage: 12 / 24 / 36 / 40.5kV
  • Rated current: 630 / 1250A
  • Short-time withstand: 20 / 25 / 31.5kA
  • Insulating medium: Dry air, SF6-free
  • Switching devices: Load break switch, vacuum circuit breaker
  • Protection: Overcurrent, earth fault, over/under voltage, auto-reclose
  • Communication: IEC 61850, DNP3, Modbus, IEC 60870-5-101/104
  • Protection rating: IP54 / IP65 optional
  • Ambient: -25°C to +55°C
  • Standards: IEC 62271-200, -100, -102
View product →
 
Maintenance-Free Pure Air / N₂ RMU 12–36kV

Pure air or nitrogen insulated RMU, maintenance-free with zero SF6, covering 12kV up to 36kV.

  • Series: REC
  • Rated voltage: 36kV
  • Rated normal current: 630A
  • Frequency: 50 / 60Hz
  • Insulation: Pure air / nitrogen, SF6-free
  • Operation: Maintenance-free
View product →

Air-insulated primary SF6-free panels

Primary Air Insulated RMU 12/24kV

Conditioned-air, SF6-free primary RMU with sealed vacuum interruption — 2 ring incomers plus transformer feeder.

  • Rated voltage: 12kV / 24kV
  • Power-freq withstand: 50kV, 1 min
  • Lightning impulse: 125kV
  • Frequency: 50 / 60Hz
  • Insulation medium: Conditioned air — SF6-free, GWP 0
  • Breaking device: Sealed vacuum interrupter
  • Busbar current: 630A (up to 1250A on request)
  • Short-time withstand: 20kA / 3s (25kA on request)
  • Configuration: 2 ring incomers + transformer feeder (switch-fuse / VCB)
  • Standard: IEC 62271-1, -102 / -103
View product →
 
Primary Air Insulated Switchgear 12/24kV

Conditioned-air primary switchgear with sealed VCB, panel types for incomer, feeder, metering, bus-tie and transformer protection. 36kV on request.

  • Rated voltage: 12kV / 24kV (36kV on request)
  • Power-freq withstand: 50kV, 1 min
  • Lightning impulse: 125kV
  • Frequency: 50 / 60Hz
  • Insulation medium: Conditioned air — SF6-free, GWP 0
  • Breaking device: Sealed vacuum circuit breaker
  • Rated normal current: 630 / 1250A (up to 2000A on request)
  • Short-time withstand: 20kA / 3s (25kA on request)
  • Panel types: Incomer, feeder, metering, bus-tie, transformer protection
View product →

Primary SF6-Free Switchgear

Four SF6-free routes — how to choose

All four eliminate SF6. They differ in footprint, pressure, and how much of the switch room you have to rebuild.

  G3 clean gas Dry air (sealed) Conditioned air Atmospheric air
Dielectric Fluoro-ketone gas mix Dry air under pressure Conditioned air in a sealed tank Air at atmospheric pressure
GWP Near zero 0 0 0
Footprint Compact Compact Compact tank Largest — needs a switch room
Pressure Sealed, low pressure Sealed, low pressure Sealed, near atmospheric No tank pressure
Best for Closest drop-in for SF6 RMU Coastal, humid, polluted sites Indoor primary distribution Substations with space and ventilation
ROCKWILL range Primary Gas Insulated RMU (G3)
G3 RMU 33/35/40.5kV
Eco-Friendly GIS RMU 12kV
Dry Air RMU 12–40.5kV
Pure Air / N₂ RMU 12–36kV
Primary Air Insulated RMU 12/24kV
Primary Air Insulated Switchgear
Metal-Clad AIS Panel 12kV
Metalclad AIS Panel 24kV
Primary SF6-Free Switchgear
 
Project situation Recommended route Why
Replacing an SF6 RMU in an existing room G3 gas RMU Same compact footprint and cable positions, minimal civil work
Tender explicitly requires zero GWP Dry air / conditioned air GWP 0 with no fluorinated gas at all
Coastal, humid or heavily polluted site Dry Air RMU Sealed tank immune to humidity and salt, IP65 option
New indoor substation with space Primary Air Insulated Switchgear Withdrawable VCB, easy maintenance, lowest equipment cost
Smart-grid / automation requirement Dry Air RMU IEC 61850, DNP3 and IEC 60870-5-101/104 built in

Standards and testing

IEC 62271 family

Common clauses IEC 62271-1, circuit breakers IEC 62271-100, disconnectors and earthing switches IEC 62271-102, RMUs IEC 62271-103, metal-enclosed assemblies IEC 62271-200.

Type and routine tests

Dielectric, temperature-rise, short-circuit and mechanical endurance type tests at recognised laboratories; routine dielectric and operation tests on every unit.

Tender documentation

Single-line drawings, gas data, IP ratings and IEC test reports issued with the offer, so the SF6-free claim can be verified by the reviewer.

Primary SF6-Free Switchgear

Specify your SF6-free primary switchgear

Tell us the voltage class, single-line diagram and whether the project requires zero GWP. We will propose the right dielectric route with a type-tested datasheet and quote.

Documentation Resource Library G3 Switchgear

SM66 type 36kV 40.5kV air insulated Ring Main Unit (RMU)
Restricted
SM66 type 36kV 40.5kV air insulated Ring Main Unit (RMU) SM66 type 36kV 40.5kV air insulated Ring Main Unit (RMU)
Catalogue
English
PDF
ZF HV Gas-Insulated Switchgear (GIS)
Restricted
ZF HV Gas-Insulated Switchgear (GIS) ZF HV Gas-Insulated Switchgear (GIS)
Catalogue
English
PDF
ZHW-145-HGIS HV Gas Insulated Switchgear
Restricted
ZHW-145-HGIS HV Gas Insulated Switchgear ZHW-145-HGIS HV Gas Insulated Switchgear
Catalogue
English
PDF
3.6kV to 12kV Indoor Metal-clad Withdrawable Switchgear Catalog
Restricted
3.6kV to 12kV Indoor Metal-clad Withdrawable Switchgear Catalog 3.6kV to 12kV Indoor Metal-clad Withdrawable Switchgear Catalog
Catalogue
English
PDF
SF6-free MV air-insulated switchgear catalogue
Public
SF6-free MV air-insulated switchgear catalogue SF6-free MV air-insulated switchgear catalogue
Catalogue
English
SF6-free MV air-insulated switchgear used manual
Public
SF6-free MV air-insulated switchgear used manual SF6-free MV air-insulated switchgear used manual
Operating Instruction
English
SF6-free MV air-insulated switchgear drawing
Public
SF6-free MV air-insulated switchgear drawing SF6-free MV air-insulated switchgear drawing
Drawings
English

Certifcations G3 Switchgear

  • XGN(RMR)-40.5-V/1250-31.5 Complete Sealed and Gas Insulated Ring Main Unit Switchgear
  • KYN28-24/3150-40 Indoor ac armored removable switchgear
  • SM66-24/DM 24kV Medium Voltage Switchgear
  • SM66-24/QM Medium Voltage Switchgear
  • SM66-24/IM Medium Voltage Switchgear
  • KYN28-24/2000-25 indoor ac metal-clad switchgear

Frequently asked questions

Primary distribution switchgear that performs the same duty as an SF6 ring main unit but uses a zero-GWP dielectric instead — G3 clean gas, dry air, conditioned air or atmospheric air — with vacuum interrupters still doing the switching.

No. Voltage, current and fault ratings are set by the vacuum interrupter and the tank design, not by the gas. ROCKWILL SF6-free units cover 12–40.5kV, 630–1250A and 20–31.5kA, matching equivalent SF6 models.

G3 is the closest drop-in for an existing SF6 RMU because the footprint barely changes. Dry air suits coastal, humid or polluted sites and adds smart-grid communication. Conditioned air is the economical choice for new indoor primary substations.

Usually yes if the replacement keeps the same tank envelope and cable termination positions — which is why G3 units are preferred for retrofit. Where space is generous, air-insulated panels can also be used with modified civil works.

IEC 62271-1 with IEC 62271-100, -102 / -103 and -200 depending on the switching devices and assembly type, supported by type-test reports and routine tests per unit.

Know your supplier

Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m² Total staff: 700+ Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: Medium and High Voltage Switchgear/Power and Distribution Transformers/Instrument Transformers and Sensors/Lightning Protection and Electrical Insulation/Substations and E-Houses/Electrical Panel and Controlgear

Comments

Share your question or perspective
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.
Login
or continue with
New here?
Register