• 3.2KW 5KW 8KW 11KW PC/PW PV inverter
  • 3.2KW 5KW 8KW 11KW PC/PW PV inverter
3.2KW 5KW 8KW 11KW PC/PW PV inverter
$4800.00
Model
PVINV1-8000
PVINV1-5000
PVINV1-3200
PVINV-11000
PVINV-8000
PVINV-5000
PVINV-3200
Basic info
Brand Wone
Model NO. PC/PW PV inverter
Mounting type rackmounting
Rated Output Rating 8kW
Input Voltage DC48V
Rated PV input power 8kW
Series PC/PW series
Product Detail

Photovoltaic inverter 

Peculiarity

  •  Dual phase inverter.

  •  IP54 protection grade, support outdoor use.

  •  Backward compatible with traditional lead batteries, colloidal batteries.

  •  PC/PW up to 9 parallel, output power up to 45KW.

  • The panel integrates a variety of interfaces, supporting a variety of protocols of the host computer and battery pack.

  • Integrated MPPT, maximize the press of the remaining power of the photovoltaic panel.

  •  Highly integrated, feature-rich, one machine at most.

  • Can be customized adjustment management battery charging and discharging strategy.

  • Modular design, easy maintenance.

Technical parameter

image.png

image.png

image.png

How does MPPT dynamically adjust the input voltage and current?

The output characteristics of photovoltaic (PV) panels change with variations in factors such as light intensity and temperature. Under different conditions, the output power curve of the PV panel will vary, and there is an optimal working point—the Maximum Power Point (MPP). At this point, the panel's output power is at its maximum. The goal of MPPT (Maximum Power Point Tracking) technology is to find and track this maximum power point in real time, ensuring that the photovoltaic system always operates at the most efficient state. The Perturb and Observe (P&O) method is a common approach used for MPPT.

  • Basic Principle: By periodically changing the output voltage (or current) of the photovoltaic array and observing the change in output power, it is possible to determine whether the system is close to the maximum power point.

  • Working Process: If the output power increases after changing the voltage (or current), continue to change in that direction; if the output power decreases, change in the opposite direction.

  • Advantages and Disadvantages: The P&O method is simple and easy to implement, but it may lead to oscillation, especially under rapidly changing light conditions.

  • Working Process: If the output power increases after changing the voltage (or current), continue to change in that direction; if the output power decreases, change in the opposite direction.



Know your supplier
Wone
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
The safe and economical operation of power transformers is related to the safety, economy, stability, and reliability of the operations of various industries. The limitations of conditions such as the investment economic indicators for its selection, the economic benefits of maintenance and operation, and the adaptability in the new environment (access of distributed power sources, configuration of energy storage, etc.) make it impossible to include comprehensive factors in other aspects.The cap
Leon
07/17/2025
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
1 IntroductionLow - voltage current transformers for metering, with a through - core type epoxy resin structure, are widely used in distribution transformer areas and for small - to - medium - sized industrial and commercial electricity consumption. As a range expander for electric energy metering, their performance directly relates to electricity consumption safety and the accuracy of users' trade calculations. Studying long - term immersion's impact on these transformers is practically signifi
Felix Spark
07/17/2025
What is reactive power measurement?
What is reactive power measurement?
The power which exists in the circuit when the voltage and current are out of phase to each other, such type of power is known as the reactive power. The formula measures the reactive power in the circuitReactive Power Measurement & VarmetersReactive power measurement is critical as it indicates circuit power loss: low reactive power worsens load power factor, increasing system losses. Varmeters (volt-ampere reactive meters) measure reactive power and are categorized by circuit phases:Single
Edwiin
07/17/2025
How to Design and Install a Solar PV System?
How to Design and Install a Solar PV System?
Design and Installation of Solar PV SystemsModern society relies on energy for daily needs like industry, heating, transport, and agriculture, mostly met by non-renewable sources (coal, oil, gas). However, these cause environmental harm, are unevenly distributed, and face price volatility due to limited reserves—driving demand for renewable energy.Solar energy, abundant and capable of meeting global needs, stands out. Standalone PV systems (Fig 1) offer energy independence from utilities.
Edwiin
07/17/2025
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
Low-voltage current transformers, as indispensable measurement and protection devices in power systems, often encounter various faults when used in combination with other power equipment due to environmental factors, equipment linkage issues, and improper installation and maintenance. These faults not only affect the normal operation of power equipment but may also endanger personal safety. Therefore, it is necessary to gain an in-depth understanding of fault types, judgment methods, and prevent
Felix Spark
07/17/2025
What are the monitoring methods and future development trends of low-voltage voltage transformers?
What are the monitoring methods and future development trends of low-voltage voltage transformers?
With the continuous advancement of smart grid technology, intelligent monitoring systems are playing an increasingly important role in preventing and addressing faults in voltage transformers. These modern intelligent monitoring systems can collect key parameters from voltage transformers in real time—such as partial discharge levels, temperature, and oil quality—and use data analysis algorithms to assess the health status of the equipment, enabling early fault warnings and precise l
Echo
07/16/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!