• 1100kV UHV SF6 Circuit Breaker
1100kV UHV SF6 Circuit Breaker
discuss personally
Model
LW10B-1100/4000-63
Basic info
Brand Wone
Model NO. 1100KV/4000A SF6 Circuit Breaker
Rated voltage 1100KV
Rated normal current 4000A
Series LW10B
Product Detail

Description:

SF6 circuit-breaker is a double-column four-fracture form, with a shunt capacitor and a closing resistor at interrupter chamber breaks; The circuit-breaker has compact structure, small arc extinguishing chamber, high contact speed, stable and reliable performance, long service life and high comprehensive technical and economic index.

SF6 circuit-breaker is outdoor three-phase AC 50Hz UHV transmission equipment, which is used to control, measure, protect and switch transmission lines in the power system with a rated voltage of 1000 kV. It can also be used to meet the capacitive current of the filter bank and capacitor bank to realize the control and protection of the filter bank and capacitor bank. The circuit-breaker is equipped with ABB HMB-8.12 compact spring hydraulic operating mechanism for division, closing and automatic reclosing. Each column has an independent hydraulic system, which can be operated in separate phases to realize single-phase automatic reclosing. Through the electrical linkage can also be three-phase linkage operation to achieve three-phase automatic reclosing.


Main Features:


  • Double column four fracture form, interrupter chamber fracture parallel capacitor and closing resistor, Cut back on oil.

  • The mechanical reliability of the product is good, to ensure the mechanical life of 10,000 times.

  • The circuit breaker structure is compact, the arc extinguishing chamber is small, the contact movement speed is high, the performance is stable and reliable, the service life is long, the comprehensive technical and economic indicators are high.

Technical parameter:


1719906238272.png

What kind of situation is the SF6 circuit breaker used?

Temperature Control:

  • Control the temperature of the installation environment to avoid adverse effects on the breaker's performance due to excessively high or low temperatures.

  • Avoid installing the breaker in locations exposed to direct sunlight or experiencing extreme temperature fluctuations.

Moisture Prevention Measures:

  • Implement moisture prevention measures to prevent water from entering the interior of the breaker, which can affect insulation performance and the normal operation of mechanical components.

  • Regularly inspect and clean the area around the equipment to remove dust and contaminants, preventing them from affecting the device's performance.


Know your supplier
Wone
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
The safe and economical operation of power transformers is related to the safety, economy, stability, and reliability of the operations of various industries. The limitations of conditions such as the investment economic indicators for its selection, the economic benefits of maintenance and operation, and the adaptability in the new environment (access of distributed power sources, configuration of energy storage, etc.) make it impossible to include comprehensive factors in other aspects.The cap
Leon
07/17/2025
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
1 IntroductionLow - voltage current transformers for metering, with a through - core type epoxy resin structure, are widely used in distribution transformer areas and for small - to - medium - sized industrial and commercial electricity consumption. As a range expander for electric energy metering, their performance directly relates to electricity consumption safety and the accuracy of users' trade calculations. Studying long - term immersion's impact on these transformers is practically signifi
Felix Spark
07/17/2025
What is reactive power measurement?
What is reactive power measurement?
The power which exists in the circuit when the voltage and current are out of phase to each other, such type of power is known as the reactive power. The formula measures the reactive power in the circuitReactive Power Measurement & VarmetersReactive power measurement is critical as it indicates circuit power loss: low reactive power worsens load power factor, increasing system losses. Varmeters (volt-ampere reactive meters) measure reactive power and are categorized by circuit phases:Single
Edwiin
07/17/2025
How to Design and Install a Solar PV System?
How to Design and Install a Solar PV System?
Design and Installation of Solar PV SystemsModern society relies on energy for daily needs like industry, heating, transport, and agriculture, mostly met by non-renewable sources (coal, oil, gas). However, these cause environmental harm, are unevenly distributed, and face price volatility due to limited reserves—driving demand for renewable energy.Solar energy, abundant and capable of meeting global needs, stands out. Standalone PV systems (Fig 1) offer energy independence from utilities.
Edwiin
07/17/2025
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
Low-voltage current transformers, as indispensable measurement and protection devices in power systems, often encounter various faults when used in combination with other power equipment due to environmental factors, equipment linkage issues, and improper installation and maintenance. These faults not only affect the normal operation of power equipment but may also endanger personal safety. Therefore, it is necessary to gain an in-depth understanding of fault types, judgment methods, and prevent
Felix Spark
07/17/2025
What are the monitoring methods and future development trends of low-voltage voltage transformers?
What are the monitoring methods and future development trends of low-voltage voltage transformers?
With the continuous advancement of smart grid technology, intelligent monitoring systems are playing an increasingly important role in preventing and addressing faults in voltage transformers. These modern intelligent monitoring systems can collect key parameters from voltage transformers in real time—such as partial discharge levels, temperature, and oil quality—and use data analysis algorithms to assess the health status of the equipment, enabling early fault warnings and precise l