NAL12kV indoor air insulated isolation switch

  • NAL12kV indoor air insulated isolation switch

Key attributes

Brand Switchgear parts
Model NO. NAL12kV indoor air insulated isolation switch
Rated voltage 12kV
Rated normal current 1250A
Series NAL

Product descriptions from the supplier

Description

NAL Indoor Air Switch Disconnector is an air insulated isolation switch designed specifically for indoor power distribution scenarios. Its core is used for safe isolation and on/off control of circuits. With air as the insulation medium, it does not require SF6 gas and is suitable for the intrinsic safety and environmental protection needs of medium and low voltage distribution systems. It is a key electrical accessory to ensure the safety of circuit maintenance and equipment upkeep.
Core Features
Adopting an air insulated structure, there are no greenhouse gases such as SF6, making it environmentally friendly and pollution-free. There is no need to worry about gas leakage risks during installation and use, which is in line with the trend of green power distribution.
The switch mechanism is designed with precision, with clear opening and closing actions and accurate positioning. The insulation performance of the fracture is stable, which can reliably achieve physical isolation of the circuit and ensure maintenance safety.
Integrate multiple anti misoperation interlocks (such as opening and closing position interlocks, grounding interlocks), strictly follow power safety regulations, and effectively avoid safety hazards caused by misoperations.
The shell is made of corrosion-resistant and anti-aging materials, with high mechanical strength, suitable for complex environments such as indoor distribution rooms, industrial plants, and commercial buildings, and easy installation and maintenance.
Applicable scenarios
Adapting to medium and low voltage indoor distribution systems, it is widely used in transformer circuits, distribution line branches, electrical equipment front-end and other scenarios. It can be used as a key component for maintenance isolation, load isolation and circuit conversion, and is suitable for industrial distribution, urban distribution networks, commercial complexes, data centers and other places.

Standard

The LBS complies with the following specifications in accordance with DIN VDE and therelevant IEC publications:60129, 60265, 60694, GOST 1516.3-96, GOST 17717-79, and CSA Standard No.C22.2, No. 193, and IEC62271-105, all of which consider switches for general use and ensurethere is safe switching coordination between a switch disconnector and a current limiting fuse.

parameter table

Model NO.

NAL

Poles Number

3

Type

Circuit Breaker

Function

Over current Protection, Load Break Switch

Certification

ISO9001-2000, CCC, Type Testing

Transport Package

Normal Export Case

Origin

China

HS Code

8538900000

FAQ
Q: What advantages does NAL12kV indoor air insulated isolation switch have?
A:

Key advantages: ① Air insulation design, no SF6 gas, environmentally friendly and maintenance-free; ② Visible breaking gap, in line with safety operation specifications, easy to check isolation status; ③ Compact structure, small installation space, suitable for indoor switchgear; ④ High mechanical strength, reliable operation, service life up to 10,000 times of opening and closing; ⑤ Good corrosion resistance, adaptable to harsh indoor industrial environments.

Q: What is the core function and working principle of NAL12kV indoor air insulated isolation switch?
A:

Its core function is to provide visible isolation in 12kV indoor power distribution systems, ensuring safe maintenance of electrical equipment and isolating faulty sections to avoid power grid accidents. Working principle: It relies on air as the insulation medium, and realizes circuit on/off and isolation through manual or electric operation of the moving contact and fixed contact. When opened, it forms a visible breaking gap that meets the standard, achieving reliable electrical isolation between the power source and the load.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Low Voltage Electrical Apparatus/Instrument meters/Production equipment/Tester/High Voltage Electrical Apparatus/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding Electrodes
    Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding ElectrodesWhen the grounding electrode of an Ultra-High-Voltage Direct Current (UHVDC) transmission system is located close to a renewable energy power station, the return current flowing through the earth can cause a rise in ground potential around the electrode area. This ground potential rise leads to a shift in the neutral-point potential of nearby power transformers, inducing DC bias (or DC offset) in their
    01/15/2026
  • HECI GCB for Generators – Fast SF6 Circuit Breaker
    1.Definition and Function1.1 Role of the Generator Circuit BreakerThe Generator Circuit Breaker (GCB) is a controllable disconnect point located between the generator and the step-up transformer, serving as an interface between the generator and the power grid. Its primary functions include isolating generator-side faults and enabling operational control during generator synchronization and grid connection. The operating principle of a GCB is not significantly different from that of a standard c
    01/06/2026
  • Distribution Equipment Transformer Testing, Inspection, and Maintenance
    1.Transformer Maintenance and Inspection Open the low-voltage (LV) circuit breaker of the transformer under maintenance, remove the control power fuse, and hang a “Do Not Close” warning sign on the switch handle. Open the high-voltage (HV) circuit breaker of the transformer under maintenance, close the grounding switch, fully discharge the transformer, lock the HV switchgear, and hang a “Do Not Close” warning sign on the switch handle. For dry-type transformer maintenance: first clean the porcel
    12/25/2025
  • How to Test Insulation Resistance of Distribution Transformers
    In practical work, insulation resistance of distribution transformers is generally measured twice: the insulation resistance between thehigh-voltage (HV) windingand thelow-voltage (LV) winding plus the transformer tank, and the insulation resistance between theLV windingand theHV winding plus the transformer tank.If both measurements yield acceptable values, it indicates that the insulation among the HV winding, LV winding, and transformer tank is qualified. If either measurement fails, pairwise
    12/25/2025
  • Design Principles for Pole-Mounted Distribution Transformers
    Design Principles for Pole-Mounted Distribution Transformers(1) Location and Layout PrinciplesPole-mounted transformer platforms should be located near the load center or close to critical loads, following the principle of “small capacity, multiple locations” to facilitate equipment replacement and maintenance. For residential power supply, three-phase transformers may be installed nearby based on current demand and future growth projections.(2) Capacity Selection for Three-Phase Pole-Mounted Tr
    12/25/2025
  • Transformer Noise Control Solutions for Different Installations
    1.Noise Mitigation for Ground-Level Independent Transformer RoomsMitigation Strategy:First, conduct a power-off inspection and maintenance of the transformer, including replacing aged insulating oil, checking and tightening all fasteners, and cleaning dust from the unit.Second, reinforce the transformer foundation or install vibration isolation devices—such as rubber pads or spring isolators—selected based on the severity of vibration.Finally, strengthen sound insulation at weak points of the ro
    12/25/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86

IEE Business will not sell or share your personal information.

Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.