• 252kV HV SF6 circuit breaker
252kV HV SF6 circuit breaker
$1300.00
Model
LW43-252
Basic info
Brand ROCKWILL
Model NO. LW43-252 high voltage SF6 circuit breaker
Rated voltage 252kV
Rated normal current 4000A
elevation 1000m
Series LW43-252
Product Detail

Description:

LW43-252 High Voltage SF6 Circuit Breaker is a three-pole AC 50Hz outdoor high voltage switchgear. It is mainly used for the control and protection of 220kV power system, and can also be used as a contact circuit breaker.

Industry applications:

LW43-252 High Voltage SF6 Circuit Breaker is a three-pole AC 50Hz outdoor high voltage switchgear. It is mainly used in 220kV power system.

Control and protection, can also be used as a contact circuit breaker.

Features:

  • Strong self-energy arc extinguishing and breaking ability.

  • The structure is simple.

  • An elongated spout is used, and a new filler is added to the material.

  • Long electrical life.

  • Strong carrying capacity.

  • Good insulation performance.

  • The seal structure is reliable.

  • Low radio interference voltage.

  • Low operating noise.

  • There is no oil leakage and air leakage in the mechanism.

  • Easy on-site installation.

  • Low amount of operation and maintenance.

Technical parameters:

image.png

image.png

Dimension:

image.png

Product show:


20140827084407.jpg


Why choose us:

  • We have a professional service team.

  • We have good after-sales.

  • We can guarantee the quality of our products.

What are the pressure requirements in the interrupter interrupter of a tank circuit breaker?

The SF₆ gas in the arc quenching chamber of a tank-type circuit breaker needs to be maintained within a certain pressure range, typically between 0.4 MPa and 0.7 MPa. Maintaining the appropriate gas pressure is a key factor in ensuring the insulation and arc-quenching performance of the gas.

  • High Pressure: If the gas pressure is too high, it can place excessive stress on the sealing structure of the arc quenching chamber, increasing the risk of leaks.

  • Low Pressure: If the gas pressure is too low, the insulation strength and arc-quenching capability of the SF₆ gas will decrease, making it ineffective in extinguishing arcs. This can even lead to circuit breaker failures.

As the ambient temperature changes, the pressure of the SF₆ gas will also change accordingly. Therefore, it is necessary to monitor and adjust the gas pressure under different temperature conditions to ensure that it remains within the normal operating pressure range.



Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
What is the difference between a dielectric and an insulator?
What is the difference between a dielectric and an insulator?
Dielectrics and insulators are distinguished primarily by their applications. One of the main differences is that a dielectric can store electrical energy by becoming polarized in an electric field, whereas an insulator resists the flow of electrons to prevent current conduction. Other key differences between them are outlined in the comparison chart below.Definition of DielectricA dielectric material is a type of insulator that contains few or no free electrons. When subjected to an electric fi
Edwiin
08/30/2025
Fault Analysis and Treatment of Oil-Immersed Transformers
Fault Analysis and Treatment of Oil-Immersed Transformers
Oil Leakage at Welded JointsOil leakage at welded joints primarily stems from poor welding quality, such as incomplete or detached welds, and defects like pinholes and gas pores. Although oil-immersed transformers are initially coated with solder and paint during manufacturing, potentially masking these issues temporarily, the defects tend to surface during operation. Additionally, electromagnetic vibration can cause weld cracks, leading to oil leakage.To resolve such leaks, the first critical s
Edwiin
08/29/2025
What losses occur during operation of the transformer? How to reduce losses?
What losses occur during operation of the transformer? How to reduce losses?
Transformers experience various types of losses during operation, primarily categorized into two main types: copper losses and iron losses.Copper LossesCopper losses, also known as I²R losses, are caused by the electrical resistance of the transformer windings—typically made of copper. As current flows through the windings, energy is dissipated in the form of heat. These losses are proportional to the square of the load current (I²R), meaning they increase significantly with high
Rockwell
08/29/2025
Cable Fault Detection, Testing, Location and Repair
Cable Fault Detection, Testing, Location and Repair
I. Methods for Cable Testing and Inspection:Insulation Resistance Test: Use an insulation resistance tester to measure the insulation resistance value of the cable. A high insulation resistance value indicates good insulation, while a low value may suggest insulation problems requiring further investigation.Voltage Withstand Test: Apply a high-voltage test using a high-voltage tester to verify whether the cable can withstand high voltage under its rated operating conditions. Under normal circums
Leon
08/29/2025
Cable Quality Inspection and Cable Detection & Testing
Cable Quality Inspection and Cable Detection & Testing
Power cable quality inspection and cable testing are conducted to ensure that the cable's quality and performance meet specified requirements, thereby guaranteeing the safe and stable operation of power systems. Below are some common contents of power cable quality inspection and cable testing:Visual Inspection: Check the cable surface for physical defects such as damage, deformation, or scratches to ensure the cable's exterior is intact.Dimensional Measurement: Measure dimensional parameters su
Edwiin
08/29/2025
Transformer Detection, Testing, Maintenance and Servicing
Transformer Detection, Testing, Maintenance and Servicing
Transformer testing, inspection, and maintenance are essential tasks to ensure normal operation and extend the service life of transformers. Below are some recommended steps:Visual Inspection: Regularly inspect the transformer's exterior, including the enclosure, cooling system, and oil tank. Ensure the enclosure is intact, free from corrosion, damage, or leakage.Insulation Resistance Testing: Use an insulation resistance tester to check the transformer's insulation system. Verify that the insul