Nizkočestotna on-line napajalna enota UPS (3fazni vhod in 3fazni izhod)

  • Low frequency on-line UPs power supply (3phase in and 3phase out)

Ključne lastnosti

Znamka Switchgear parts
Model št Nizkočestotna on-line napajalna enota UPS (3fazni vhod in 3fazni izhod)
Nominativna frekvenca 50/60Hz
Vhodna napetost 380VAC
Kapaciteta 10kVA
Serija HBS

Opisi izdelkov od dobavitelja

Opis

Serija HBS visokomosne tri v tri izhodne inteligentne neprekinjene napajalne enote ima kapaciteto enega stroja, ki se giblje od 6KVA do 400KVA. Ta izdelek je zelo inteligenten napajalni izdelek, ki združuje digitalizacijo, informatizacijo in omrežje. Uporablja hitri mikroprocesor (MCU) in ASIC DDC nadzorno tehnologijo ter ima močno
Sistem za shranjevanje velikih informacij, sistem za obdelavo signalov, nadzorni sistem in sistem celostnega zaščite; široko uporabljajo v različnih električnih okoljih, kot so visoki stroski, javno osvetlitev, električna energija, industrijska in rudarska podjetja, omrežne računalniške dvoranice in druge industrije. Personalizirano oblikovanje, prijazna funkcija človek-računalnik interakcije, intuitivni slovenski in angleški barvni
Barvni zaslonski prikaz in statusna indikatorja nadzorne ploskev omogočata preprosto uporabo in raba.

Značilnosti izdelka

Inteligentna digitalna nadzorna tehnologija:
Uporaba hitrih mikrokrmilnikov in programabilnih logičnih naprav za dosego nadzora krmarjenja, nastavitve parametrov, upravljanja delovanja, naprednih samopregledov in samodiagnostike, lahko izvaja samopreglede in analizo napak na vseh neodvisnih vezavskih povezavah na vezivu. Lahko polnost zaupate v digitalno pretvorjeno sinusoidno napetost in novo rešitev za popolno delovanje, da bi ustrezali vašim dejanskim potrebam. )
Učinkovita IGBT (Izolirana vrata dvopolarni tranzistor) inverterna tehnologija:
Dobra značilnost hitrega preklopa IGBT; imajo delovne značilnosti visoke napetosti in visokega toka; uporaba nadzora tipa napetost, za katerega je potreben le majhen kontrolni vir napetosti. Peta generacija IGBT ima nižjo nasičeno padec napetosti, višjo učinkovitost inverterja in višjo zaupanja vrednost.
Prilagodljiva vzporedna tehnologija:
Ustreza enemu stroju, 1+1 vzporedno, in N+1 vzporedno redundancijskim sistemom s različnimi obremenitvami.
Izstopajoče značilnosti obremenitve:
Uporaba popolnoma neodvisne PWM modulacije in polnega mosta IGBT inverterne tehnologije, popolnoma zadostva za prehod od 0 do 100% obremenitve brez preklopa na omrežje, in varuje stabilno in zanesljivo izhodno napetost.
Človeku prijazna 7-inčna velika LCD zaslona s slovenskim in angleškim barvnim dotikom zaslona:
Veliki 7-inčni LCD zaslon prikazuje slovenska in angleška menija, z jasnim tokom prikaza stanja delovanja in prilagodljive funkcije človek-računalnik interakcije. Dotikalni zaslon ima prikaz zapisov dogodkov in operacije menija v slovenščini in angleščini so na voljo.
Popolna funkcija zaščite:
Večkratna sistemska zaščitna in alarmna funkcija, vključno s prekomernim in izhodnim prekomernim nadzorom, vhodno valovno zaščito, fázno zaporedje zaščite, baterijsko prekomerno nabiranje in razpiranje zaščite, izhodno preobremenitev in krajšanje zaščite, in visoka temperatura zaščite.
Visoko zmogljivi dinamični značilnosti:
Uporaba večkratne povratne nadzorne metode, kot sta trenutna nadzorna in efektivna vrednost, za dosego visokih dinamičnih regulacij in zmanjšanje prekrivnice napetosti.
6 impulsov (fakultativno 12 impulsov)
Rectifier charger dodaja tudi vhodni harmonski filter za učinkovito utlačevanje vhodne harmonske onesnaženosti, izboljšanje vhodnega faktorja moči UPS napajalnika in zmanjšanje vhodnega harmonskega toka.
Inteligentno upravljanje baterije:
Inteligentno nabiranje baterije, avtomatsko prilagodi parametre nabiranja baterije glede na konfiguracijo baterije uporabnika, in izvaja enačenje in plavajočo nabiranje, temperaturno kompenzacijo nabiranja, razpiranje upravljanja glede na okolje oskrbe, da bi podaljšali življenjski čas baterije in zmanjšali breme administratorjev.
Popolna izolacijska tehnologija
Vhod in izhod so popolnoma izolirani, da se zmanjšajo harmonski tokovi in neposredni motnji iz omrežja.
Inteligentno komunikacijsko upravljanje:
RS232 in RS485 komunikacijski vmesniki resnično omogočajo večnamensko komunikacijo in oddaljen nadzor. Fakultativna SNMP kartica omogoča oddaljen nadzor in omrežno upravljanje, fakultativni suhi kontakt vmesnik uporablja pasivne kontakte za nadzor stanja UPS.

Tehnične specifikacije

Model HBS-6KS HBS-10KS HBS-15KS HBS-20KS HBS-30KS HBS-40KS HBS-50KS HBS-60KS HBS-80KS HBS-100KS HBS-120KS HBS-150KS HBS-200KS HBS-250KS HBS-300KS HBS-400KS
Nominal Capacity (kVA) 6 10 15 20 30 40 50 60 80 100 120 150 200 250 300 400
Overall Working Mode and Principle Online Power Supply, Static Bypass Switch (Uninterrupted Switching), Double Conversion Technology, Output Power Fully Isolated
Rectifier Working Mode 6-pulse (12-pulse Optional) Rectification

Input  
Phase Number

Three Phase + N + G

Nominal Voltage 380VAC ± 25%
Nominal Frequency 50Hz ± 5%, 60Hz ± 5%
Voltage Harmonic Distortion < 5%
Soft Start 0-100% 5S
Nominal Output DC Voltage 405VDC
Rated Power (KW, Cosφ=0.8) Nominal Power × 0.8
Inverter  
Phase Number Three Phase + N + G
Nominal Voltage 380VAC ± 1% (Stable Load), 380VAC ± 5% (Load Fluctuation)
Nominal Frequency 50Hz ± 0.5%, 60Hz ± 0.5% (Battery Power Supply)
Frequency Stability < ± 0.5% (Asynchronous)
Frequency Tracking Range 50Hz ± 5%
Crest Factor 3:1
Output Waveform Sine Wave
Output Waveform Distortion Linear Load < 3%; Non-linear Load < 5%
Dynamic Load Voltage Transient < ± 5% (0 to 100% Load Change)
Instantaneous Recovery Time < 10ms
Overload Capacity 125% 1min, 150% 1s
Inverter Efficiency ≥95% (100% Load)
Bypass  
Phase Number Three Phase + N + G
Nominal Voltage 380VAC ± 25%
Nominal Frequency 50Hz ± 5%, 60Hz ± 5%
Conversion Time 0ms (Inverter/Bypass)
Battery Charging  
Battery Type Maintenance-free Lead-acid Battery
Maximum Output Voltage 220vdc/405vdc 220vdc/405vdc 220vdc/405vdc 220vdc/405vdc 405VDC 405VDC 405VDC 405VDC 405VDC 405VDC 405VDC 405VDC 405VDC 405VDC 405VDC 405VDC
Microcomputer-set Charging Current 1A~100A (Set According to Battery Capacity, Automatically Adjusted to 0.1C)
Quantity Unit 16 cells/30 cells 12V in series 16 cells/30 cells 12V in series 16 cells/30 cells 12V in series 16 cells/30 cells 12V in series 30 cells/12V in series (180 cells/2V in series) 30 cells/12V in series (180 cells/2V in series) 30 cells/12V in series (180 cells/2V in series) 30 cells/12V in series (180 cells/2V in series) 30 cells/12V in series (180 cells/2V in series) 30 cells/12V in series (180 cells/2V in series) 30 cells/12V in series (180 cells/2V in series) 30 cells/12V in series (180 cells/2V in series) 30 cells/12V in series (180 cells/2V in series) 30 cells/12V in series (180 cells/2V in series) 30 cells/12V in series (180 cells/2V in series) 30 cells/12V in series (180 cells/2V in series)
Charging Current 1A~100A (Automatically Adjusted to 0.1C According to Battery Capacity)
Nominal Battery Voltage 192VDC/360VDC 192VDC/360VDC 192VDC/360VDC 192VDC/360VDC 360VDC 360VDC 360VDC 360VDC 360VDC 360VDC 360VDC 360VDC 360VDC 360VDC 360VDC 360VDC
Float Voltage 220VDC/405VDC 220VDC/405VDC 220VDC/405VDC 220VDC/405VDC 405VDC (Battery Equalization Once Every 3 Months, Charging Voltage 435VDC) 405VDC (Battery Equalization Once Every 3 Months, Charging Voltage 435VDC) 405VDC (Battery Equalization Once Every 3 Months, Charging Voltage 435VDC) 405VDC (Battery Equalization Once Every 3 Months, Charging Voltage 435VDC) 405VDC (Battery Equalization Once Every 3 Months, Charging Voltage 435VDC) 405VDC (Battery Equalization Once Every 3 Months, Charging Voltage 435VDC) 405VDC (Battery Equalization Once Every 3 Months, Charging Voltage 435VDC) 405VDC (Battery Equalization Once Every 3 Months, Charging Voltage 435VDC) 405VDC (Battery Equalization Once Every 3 Months, Charging Voltage 435VDC) 405VDC (Battery Equalization Once Every 3 Months, Charging Voltage 435VDC) 405VDC (Battery Equalization Once Every 3 Months, Charging Voltage 435VDC) 405VDC (Battery Equalization Once Every 3 Months, Charging Voltage 435VDC)
Efficiency > 80% (100% Load)
System  
Computer Communication Interface Standard RS232, Optional RS485, Dry Contact, SNMP Remote Monitoring Network Adapter
Operating Temperature 0-40℃
Relative Humidity (No Condensation) 30% - 90%
Operating Altitude (Maximum) < 1000 meters (Power Drops by 1% for Every 100 Meters Increase, Maximum 4000 Meters)
Cooling Method Temperature-controlled Forced Air Cooling
Noise dB (1m from the Machine, Depending on Load and Temperature) 40-50 40-50 45-55 45-55 50-55 50-55 55-65 55-65 55-65 55-65 55-65 65-70 65-70 65-70 65-70 65-70
Cabinet Color Black (Optional)
Input Cable Bottom/Back
Easy Maintenance Top/Left/Right Sides Can Be Opened
External Dimensions W×D×H(mm) 390×660×860 450×725×1035 710×720×1450 710×850×1500 1100×860×1680 1100×860×1680 1500×1160×1800 1500×1160×1800 1800×1250×1800 1800×1250×1800 1800×1250×1800 1800×1250×1800 1800×1250×1800 1800×1250×1800 1800×1250×1800 1800×1250×1800
Weight (kg) 150 212 260 352 396 485 568 635 903 951 1052 1355 1586 1850 2170 3155
Input and Output Devices Terminal Block
FAQ za
Q: Kateri prednosti ima v primerjavi z visokofrekvenčnimi 3-faznimi on-line UPS?
A:

V primerjavi z visokočastotnimi UPS-i ima očitne prednosti: ① Višja zanesljivost: nizkočastotni transformator ima močno preobremenitveno zmogljivost (podpira 125% preobremenitev za 10 minut) in odpornost na motnje; ② Boljša stabilnost: primerna za težke industrijske okolice z velikimi napetostnimi fluktuacijami in visokimi harmoniki; ③ Daljši življenjski čas: nizkočastotni komponenti imajo manjše segrevanje in sijanje, življenjski čas doseže 10-15 let; ④ Močnejša prilagodljivost bremenu: združljiva s induktivnimi, kapacitivnimi in upornimi bremeni (kot so motorji, inverterji).

Q: Kaj je osrednja funkcija in delovanje nizkočastotnega on-line UPS-a s 3-faznim vhodom in 3-faznim izhodom?
A:

Njegova osnovna funkcija je zagotavljanje neprekinjenega, stabilnega in čistega električnega torjenja za visokomerna industrijska obremenjenja, s funkcijami stabilizacije napetosti, harmoničnega filtrovanja in zaščite pred prepadnimi spremembami. Delovni princip temelji na dvojni pretvorbi (AC-DC-AC): ko je glavno struja normalna, pretvori 3-fazno AC v DC za polnjenje baterije, nato pa pretvori DC v stabilno 3-fazno čisto sinusno valovanje AC za snabditev z obremenitvijo; ko glavna struja odpade, preklopi na baterijsko snabdevanje z 0ms prehodnim časom, kar zagotavlja, da ne bo nobenega odpiranja obremenitve.

Poznajte svojega dobavitelja
Spletna trgovina
Stopnja pravočasne dobave
Čas odziva
100.0%
≤4h
Pregled podjetja
Delovni prostor: 1000m² Skupno število zaposlenih: Najvišja letna izvozna vrednost v dolarjih: 300000000
Delovni prostor: 1000m²
Skupno število zaposlenih:
Najvišja letna izvozna vrednost v dolarjih: 300000000
Storitve
Vrsta posla: Prodaja
Glavne kategorije: Opremi za opremo/Preverjanje opreme/Visokonapetostna oprema/Nizko napetostna oprema/merila in naprave/Proizvodno opremo/električni pribor
Trajni zavarovalni upravnik
Storitve upravljanja z vsoživljenjsko oskrbo za nabavo opreme, uporabo, vzdrževanje in servis po prodaji, ki zagotavljajo varno delovanje električne opreme, neprekinjen nadzor in brezskrbno porabo električne energije.
Dobavitelj opreme je opravil potrdilo o ustreznosti platforme in tehnično oceno, s čimer zagotavlja skladnost, strokovnost in zanesljivost že v izvoru.

Povezani izdelki

Povezane znanje

  • Nesreče glavnega transformatorja in težave pri delovanju lahkega plina
    1. Zapis o nesreči (19. marec 2019)Dne 19. marca 2019 ob 16:13 je nadzorno okolje poročalo o dejanju svetega plina na glavnem transformatorju št. 3. V skladu s Pravilnikom za delovanje močnih transformatorjev (DL/T572-2010) so održevalci (O&M) preverili stanje glavnega transformatorja št. 3 na mestu.Potrditev na mestu: Na plošči neelektrične zaščite WBH glavnega transformatorja št. 3 je bil zaznan dejanje svetega plina v faznem B delu transformatorja, ponovno postavitev pa ni bila učinkovita
    02/05/2026
  • Napake in njihova obdelava pri enofaznem talom v 10kV distribucijskih črtah
    Značilnosti in naprave za zaznavanje enofaznih ozemljitvenih okvar1. Značilnosti enofaznih ozemljitvenih okvarCentralni alarmni signali:Zazvoni opozorilni zvon in se prižge kazalna lučka z napisom »Ozemljitvena okvara na [X] kV avtobusu, odsek [Y]«. V sistemih z izgubno tuljavo (tuljavo za ugasitev loka) za ozemljitev srednje točke se prav tako prižge kazalna lučka »Izgubna tuljava v obratovanju«.Indikacije voltmetra za nadzor izolacije:Napetost okvarjene faze se zmanjša (pri nepopolni ozemljitv
    01/30/2026
  • Neutralni točka povezava za transformatorje elektroenergetskega omrežja 110kV~220kV
    Način zemljanja neutralne točke transformatorjev v omrežju napetosti 110kV~220kV mora zadostovati zahtevam izolacije neutralne točke transformatorja in se prav tako truditi ohraniti neničelno impedanco preobrazovalnic praktično nespremenjeno, hkrati pa zagotavlja, da neničelna celostna impedanca pri katerikoli kratkoporočni točki v sistemu ne presega trikratnice pozitivne celostne impedanci.Za 220kV in 110kV transformatorje v novih gradnji in tehničnih prenovah morajo njihovi načini zemljanja ne
    01/29/2026
  • Zakaj podstanice uporabljajo kamenje šiske male kamenčke in drobljen kamen
    Zakaj podstanice uporabljajo kamen, grud, krike in drobljen kamen?V podstanicah je za opremo, kot so prenosni in distribucijski transformatorji, prenosne linije, napetostni transformatorji, tokovni transformatorji in odskokne vložke, potrebno zemljenje. Poleg zemljenja bomo zdaj podrobneje raziskali, zakaj so gruda in drobljen kamen v podstanicah pogosto uporabljana. Čeprav izgledajo običajno, imajo ti kameni ključno vlogo za varnost in funkcionalnost.V načrtovanju zemljenja podstanic—zlasti, ko
    01/29/2026
  • Zakaj mora biti jedro transformatorja zazemljeno le na eni točki Ne bi bilo večtočkovno zazemljanje bolj zanesljivo
    Zakaj je potrebno zemljiti jedro transformatorja?Med delovanjem se jedro transformatorja skupaj s kovinskimi strukturami, deli in komponentami, ki fiksirajo jedro in viklinke, nahajajo v močnem električnem polju. Pod vplivom tega električnega polja pridobijo relativno visok potencial glede na zemljo. Če ni zemljitev jedra, bo obstajala razlika potencialov med jedrom in zemljenimi priklopni strukturami ter rezervoarjem, kar lahko vodi do intermitentnega izboja.Dodatno, med delovanjem okoli viklin
    01/29/2026
  • Razumevanje nevtralnega priključka transformatorja
    I. Kaj je nevtralna točka?V transformatorjih in generatorjih je nevtralna točka določena točka v zavojnici, kjer je absolutna napetost med to točko in vsakim zunanjim terminalom enaka. Na spodnjem diagramu točkaOprikazuje nevtralno točko.II. Zakaj je potrebno nevtralno točko zazemliti?Električna povezava med nevtralno točko in zemljo v sistemih trofazne stromo napetosti se imenujemetoda zazemljanja nevtralne točke. Ta način zazemljanja neposredno vpliva na:Varnost, zanesljivost in ekonomičnost e
    01/29/2026
Še niste našli pravilnega dobavitelja Pustite preverjene dobavitelje, da vas najdejo Pridobi Ponudbo Tujma