Niski frekvencijski on-line UPS napajanje (3fazni ulaz i 3fazni izlaz)

  • Low frequency on-line UPs power supply (3phase in and 3phase out)

Ključni atributi

Marka Switchgear parts
Broj modela Niski frekvencijski on-line UPS napajanje (3fazni ulaz i 3fazni izlaz)
Nominirana frekvencija 50/60Hz
Ulazni napon 380VAC
kapacitet 6kVA
Serija HBS

Opisi proizvoda od dobavljača

Opis

Niz HBS visokosnažnih trofaznih UPS-a s tri ulaza i tri izlaza ima jediničnu snagu od 6KVA do 400KVA. Ovaj proizvod je vrlo inteligentan napajajući proizvod koji integrije digitalizaciju, informatizaciju i mrežno povezanost. Koristi visokobrzinski mikroprocesor (MCU) i ASIC DDC kontrolnu tehnologiju, te ima snažne
sustave za prikupljanje informacija, obradu signala, nadzor i integralnu zaštitu; široko se koristi u raznim električnim okruženjima, poput visokih zgrada, cestovnog osvjetljenja, elektroprivrede, rudarskih i industrijskih poduzeća, računalnih zaliha i drugih industrija. Personalizirani dizajn, prijateljska funkcija ljudsko-računalne interakcije, intuitivni bojni displej na kineskom i engleskom jeziku
bojni displej i sučelje za nadzor stanja omogućuju korisnicima lako upravljanje i korištenje.

Značajke proizvoda

Inteligentna digitalna kontrolna tehnologija:
Korištenjem visokobrzinskih mikrokontrolera i programabilnih logičkih uređaja postiže se kontrola krugova, postavljanje parametara, upravljanje radom, napredne funkcije samoprovjere i samodiagnostike, moguće je provesti samoprovjeru i analizu grešaka na svim neovisnim spojevima na ploči. Možete potpuno vjerovati transformiranom sinusoidnom naponu i novom rješenju za savršen rad kako biste ispunili vaše stvarne potrebe. )
Učinkovita IGBT (izolirana dvopolni tranzistor) inverzorska tehnologija:
Dobra svojstva brzog prekidača IGBT-a; imaju karakteristike rada pri visokom naponu i struju; koristi se upravljanje naponskim tipom, potrebna je samo malena kontrolna snaga. Peti generacije IGBT ima niži napon zasićenja, veću učinkovitost inverzora i veću pouzdanost.
Sposobnost fleksibilnog paralelnog rada:
Prikladan za jedinica, 1+1 paralelni i N+1 paralelni redundanci sustav s različitim opterećenjima.
Izvrsne karakteristike opterećenja:
Primjenjuje se potpuno neovisna PWM modulacija i puni most IGBT inverzorska tehnologija, što potpuno zadovoljava prelaz od 0 do 100% opterećenja bez prebacivanja na bypass, čime se osigurava stabilno i pouzdano izlazno napajanje.
Humanizirani 7-inčni veliki LCD ekran s bojnim dodirnim zaslonom na kineskom i engleskom jeziku:
7-inčni veliki LCD zaslon prikazuje meni na kineskom i engleskom jeziku, sa jasnim dijagramom toka koji pokazuje stanje rada i fleksibilnu funkciju ljudsko-računalne interakcije. Dodirni zaslon ima zabilježene događaje i operacije menija dostupne na kineskom i engleskom jeziku.
Potpuna funkcija zaštite:
Više sistema zaštite i alarmnih funkcija, uključujući zaštitu od preopterećenja i preko napona na ulazu i izlazu, zaštitu od udarnih talasa, zaštitu faze, zaštitu od preopterećenja i preiskorijenjavanja baterije, zaštitu od preopterećenja i kraćeg spoja na izlazu, te zaštitu od visoke temperature.
Visoko performantne dinamičke karakteristike:
Primjenjuju se više povratnih kontrola, kao što su trenutna kontrola i kontrola efektivne vrijednosti, kako bi se postigla visoka dinamička regulacija i smanjila distorzija napona.
Šest impulsa (opcionalno 12 impulsa)
Rectifikator naboja također dodaje filter harmonika na ulaz da bi se učinkovito supresirao ulazni harmonijski zagađivač, poboljšao faktor snage napajanja UPS-a i smanjio ulazni harmonijski strujni tok.
Inteligentno upravljanje baterijama:
Inteligentno nabavljanje baterija, automatski prilagođava parametre nabavljanja baterije prema konfiguraciji baterije korisnika, i obavlja pretvorbu iz ravnotežnog u plivajuće nabavljanje, kompenzaciju temperature, upravljanje odbijanjem na temelju okruženja snabdijevanja strujom kako bi se produžio životni vijek baterije i smanjilo opterećenje administratora.
Potpuna tehnologija izolacije
Ulaz i izlaz su potpuno izolirani kako bi se smanjili harmonijski strujni tokovi i direktno opterećenje od javne mreže.
Inteligentno upravljanje komunikacijom:
RS232 i RS485 komunikacijski priključci stvarno ostvaruju višesvrhsnu komunikaciju i daljinsko nadgledanje. Opcioni SNMP kartica omogućuje daljinsko nadgledanje i upravljanje mrežom, a opcioni suhi kontakt sučelje koristi pasivne kontakte za nadzor stanja UPS-a.

Tehničke specifikacije

Model HBS-6KS HBS-10KS HBS-15KS HBS-20KS HBS-30KS HBS-40KS HBS-50KS HBS-60KS HBS-80KS HBS-100KS HBS-120KS HBS-150KS HBS-200KS HBS-250KS HBS-300KS HBS-400KS
Nominal Capacity (kVA) 6 10 15 20 30 40 50 60 80 100 120 150 200 250 300 400
Overall Working Mode and Principle Online Power Supply, Static Bypass Switch (Uninterrupted Switching), Double Conversion Technology, Output Power Fully Isolated
Rectifier Working Mode 6-pulse (12-pulse Optional) Rectification

Input  
Phase Number

Three Phase + N + G

Nominal Voltage 380VAC ± 25%
Nominal Frequency 50Hz ± 5%, 60Hz ± 5%
Voltage Harmonic Distortion < 5%
Soft Start 0-100% 5S
Nominal Output DC Voltage 405VDC
Rated Power (KW, Cosφ=0.8) Nominal Power × 0.8
Inverter  
Phase Number Three Phase + N + G
Nominal Voltage 380VAC ± 1% (Stable Load), 380VAC ± 5% (Load Fluctuation)
Nominal Frequency 50Hz ± 0.5%, 60Hz ± 0.5% (Battery Power Supply)
Frequency Stability < ± 0.5% (Asynchronous)
Frequency Tracking Range 50Hz ± 5%
Crest Factor 3:1
Output Waveform Sine Wave
Output Waveform Distortion Linear Load < 3%; Non-linear Load < 5%
Dynamic Load Voltage Transient < ± 5% (0 to 100% Load Change)
Instantaneous Recovery Time < 10ms
Overload Capacity 125% 1min, 150% 1s
Inverter Efficiency ≥95% (100% Load)
Bypass  
Phase Number Three Phase + N + G
Nominal Voltage 380VAC ± 25%
Nominal Frequency 50Hz ± 5%, 60Hz ± 5%
Conversion Time 0ms (Inverter/Bypass)
Battery Charging  
Battery Type Maintenance-free Lead-acid Battery
Maximum Output Voltage 220vdc/405vdc 220vdc/405vdc 220vdc/405vdc 220vdc/405vdc 405VDC 405VDC 405VDC 405VDC 405VDC 405VDC 405VDC 405VDC 405VDC 405VDC 405VDC 405VDC
Microcomputer-set Charging Current 1A~100A (Set According to Battery Capacity, Automatically Adjusted to 0.1C)
Quantity Unit 16 cells/30 cells 12V in series 16 cells/30 cells 12V in series 16 cells/30 cells 12V in series 16 cells/30 cells 12V in series 30 cells/12V in series (180 cells/2V in series) 30 cells/12V in series (180 cells/2V in series) 30 cells/12V in series (180 cells/2V in series) 30 cells/12V in series (180 cells/2V in series) 30 cells/12V in series (180 cells/2V in series) 30 cells/12V in series (180 cells/2V in series) 30 cells/12V in series (180 cells/2V in series) 30 cells/12V in series (180 cells/2V in series) 30 cells/12V in series (180 cells/2V in series) 30 cells/12V in series (180 cells/2V in series) 30 cells/12V in series (180 cells/2V in series) 30 cells/12V in series (180 cells/2V in series)
Charging Current 1A~100A (Automatically Adjusted to 0.1C According to Battery Capacity)
Nominal Battery Voltage 192VDC/360VDC 192VDC/360VDC 192VDC/360VDC 192VDC/360VDC 360VDC 360VDC 360VDC 360VDC 360VDC 360VDC 360VDC 360VDC 360VDC 360VDC 360VDC 360VDC
Float Voltage 220VDC/405VDC 220VDC/405VDC 220VDC/405VDC 220VDC/405VDC 405VDC (Battery Equalization Once Every 3 Months, Charging Voltage 435VDC) 405VDC (Battery Equalization Once Every 3 Months, Charging Voltage 435VDC) 405VDC (Battery Equalization Once Every 3 Months, Charging Voltage 435VDC) 405VDC (Battery Equalization Once Every 3 Months, Charging Voltage 435VDC) 405VDC (Battery Equalization Once Every 3 Months, Charging Voltage 435VDC) 405VDC (Battery Equalization Once Every 3 Months, Charging Voltage 435VDC) 405VDC (Battery Equalization Once Every 3 Months, Charging Voltage 435VDC) 405VDC (Battery Equalization Once Every 3 Months, Charging Voltage 435VDC) 405VDC (Battery Equalization Once Every 3 Months, Charging Voltage 435VDC) 405VDC (Battery Equalization Once Every 3 Months, Charging Voltage 435VDC) 405VDC (Battery Equalization Once Every 3 Months, Charging Voltage 435VDC) 405VDC (Battery Equalization Once Every 3 Months, Charging Voltage 435VDC)
Efficiency > 80% (100% Load)
System  
Computer Communication Interface Standard RS232, Optional RS485, Dry Contact, SNMP Remote Monitoring Network Adapter
Operating Temperature 0-40℃
Relative Humidity (No Condensation) 30% - 90%
Operating Altitude (Maximum) < 1000 meters (Power Drops by 1% for Every 100 Meters Increase, Maximum 4000 Meters)
Cooling Method Temperature-controlled Forced Air Cooling
Noise dB (1m from the Machine, Depending on Load and Temperature) 40-50 40-50 45-55 45-55 50-55 50-55 55-65 55-65 55-65 55-65 55-65 65-70 65-70 65-70 65-70 65-70
Cabinet Color Black (Optional)
Input Cable Bottom/Back
Easy Maintenance Top/Left/Right Sides Can Be Opened
External Dimensions W×D×H(mm) 390×660×860 450×725×1035 710×720×1450 710×850×1500 1100×860×1680 1100×860×1680 1500×1160×1800 1500×1160×1800 1800×1250×1800 1800×1250×1800 1800×1250×1800 1800×1250×1800 1800×1250×1800 1800×1250×1800 1800×1250×1800 1800×1250×1800
Weight (kg) 150 212 260 352 396 485 568 635 903 951 1052 1355 1586 1850 2170 3155
Input and Output Devices Terminal Block
FAQ
Q: Koje prednosti ima u usporedbi s visokočestotnim 3-faznim online UPS-om?
A:

Uspoređen s UPS-om visoke frekvencije, ima očite prednosti: ① Viša pouzdanost: transformator niske frekvencije ima snažnu preopterećujuću sposobnost (podržava 125% preopterećenje tijekom 10 minuta) i otpornost na interferenciju; ② Bolja stabilnost: prikladan za teške industrijske okruženja s velikim fluktuacijama napona i visokim harmoničkim valovima; ③ Duži vijek trajanja: komponente niske frekvencije generiraju manje topline i nose manje oštećenja, vijek trajanja do 10-15 godina; ④ Snažnija sposobnost prilagodbe opterećenju: kompatibilan s induktivnim, kapacitivnim i rezistivnim opterećenjima (poput motora, invertera).

Q: Koja je osnovna funkcija i načelo rada 3-faznog ulaza i 3-faznog izlaza niskofrekventnog on-line UPS-a?
A:

Jezgra njezinog rada jest osigurati neprekidni, stabilan i čisti strujni tok za industrijske opterećenja s visokim potrošnjama snage, uz funkcije stabilizacije napona, filtriranja harmonika i zaštite od preopterećenja. Radni princip temelji se na dvostrukoj pretvorbi (AC-DC-AC): kada je mrežni struja normalan, on pretvara trofazni AC u DC kako bi se nabijala baterija, a zatim pretvara DC u stabilan trofazni čisti sinusni val AC za opskrbu opterećenja; kada mrežni struja pada, prelazi na opskrbu iz baterije s vremenom prelaska od 0ms, osiguravajući da ne dođe do isključivanja opterećenja.

Upoznajte svog dobavljača
Online trgovina
Stopničasta stopa isporuke
Vrijeme odziva
100.0%
≤4h
Pregled tvrtke
Radno mjesto: 1000m² Ukupno osoblje: Najveći godišnji izvoz (USD): 300000000
Radno mjesto: 1000m²
Ukupno osoblje:
Najveći godišnji izvoz (USD): 300000000
Usluge
Vrsta posla: Prodaja
Glavne kategorije: Oprema za uređaje/Opravna uređaja/Visoki napon uređaji/Niskonaponski uređaji/Instrumenti i mjernih uređaja/Proizvodna oprema/Električne armature
Upravitelj doživotne jamstvene osiguranja
Usluge upravljanja brinući se o opremi tijekom cijelog vijeka trajanja, od nabave do korištenja, održavanja i posloprodajnog servisa, osiguravajući sigurno funkcioniranje električne opreme, kontinuiranu kontrolu i bezbrižnu potrošnju električne energije
Dobavljač opreme prošao je certifikaciju kvalifikacije platforme i tehničku evaluaciju, osiguravajući sukladnost, profesionalnost i pouzdanost od izvora

Povezani proizvodi

Povezane znanje

  • Uticaj strujnog odstupanja u transformatorima na stanicama obnovljivih izvora energije blizu zemljišnih elektroda UHVDC
    Utjecaj DC strujnog pomaka u transformatorima na obnovljivim energetskim postajama blizu zemljišnih elektroda UHVDC sustavaKada se zemljišni elektrod Ultra Visokonaponskog Direktnog Strujnog (UHVDC) prenosnog sustava nalazi u blizini obnovljive energetske postaje, povratna struja koja teče kroz tlo može uzrokovati povećanje potencijala zemlje oko područja elektroda. Tako nastali porast potencijala zemlje dovodi do pomaka potencijala neutralne točke okolnih transformatora, što uzrokuje pojavu DC
    01/15/2026
  • HECI GCB za generatori – Brzi prekidač s šestfluoridom ugljičnim (SF₆)
    1. Definicija i funkcija1.1 Uloga prekidača generatoraPrekidač generatora (GCB) je kontrolirana točka odjedinstvenja između generatora i transformatora za povećanje napona, koja služi kao sučelje između generatora i električne mreže. Njegova glavna funkcija uključuje izolaciju grešaka na strani generatora i omogućavanje operativnog kontrole tijekom sinkronizacije generatora i povezivanja s mrežom. Način rada GCB-a nije značajno različit od standardnog prekidača; međutim, zbog visokog DC komponen
    01/06/2026
  • Pogonsko opremno ispitivanje transformatora inspekcija i održavanje
    1.Održavanje i pregled transformatora Otvorite niskonaponski (LV) prekidač transformatora koji se održava, uklonite zaštitni prekidnik napajanja upravljanja i ovisno o ručici prekidača obesite znak opozorbe "Ne zatvarati". Otvorite visokonaponski (HV) prekidač transformatora koji se održava, zatvorite zemljište, potpuno razradite transformator, zaključajte HV uređaj za prekid i na ručici prekidača obesite znak opozorbe "Ne zatvarati". Za održavanje suhoparnog transformatora: prvo očistite porcel
    12/25/2025
  • Kako testirati otpornost izolacije distribucijskih transformatora
    U praktičnom radu, otpor izolacije distribucijskih transformatora obično se mjeri dvaput: otpor izolacije između visokonaponskog (HV) namota i niskonaponskog (LV) namota zajedno s posudom transformatora, te otpor izolacije između LV namota i HV namota zajedno s posudom transformatora.Ako obje mjere daju prihvatljive vrijednosti, to ukazuje da je izolacija između HV namota, LV namota i posude transformatora zadovoljavajuća. Ako jedna od mjera ne uspije, moraju se provesti testovi otpora izolacije
    12/25/2025
  • Principi dizajna za transformatore distribucijskog napajanja montirane na stub
    Principi dizajna za transformatore snage na stubu(1) Principi lokacije i rasporedaPlatforme transformatora na stubu trebaju biti smještene blizu središta opterećenja ili uz ključne opterećenja, slijedeći princip "mala kapacitet, više lokacija" kako bi se omogućilo zamjenjivanje i održavanje opreme. Za opskrbu stanovanjske struje, trofazni transformatori se mogu instalirati u blizini temeljem trenutnog potražnje i budućih prognoza rasta.(2) Odabir kapaciteta za trofazne transformatore na stubuSta
    12/25/2025
  • Rješenja za kontrolu buke transformatora za različite instalacije
    1.Smanjenje buke za nezavisne transformatorske sobe na temeljuStrategija smanjenja:Prvo, provedite ispitivanje i održavanje transformatora u isključenoj stanju, uključujući zamjenu starog izolacijskog ulja, provjeru i zatezanje svih pričvršćiva, te čišćenje prašine s jedinice.Drugo, ojačajte temelj transformatora ili instalirajte uređaje za izolaciju vibracija—poput gumenih podloga ili opruga izolatora—izabrane prema intenzitetu vibracija.Konačno, ojačajte akustičku izolaciju na slabinim točkama
    12/25/2025
Još uvijek niste pronašli odgovarajućeg dobavljača Pustite verificirane dobavljače da vas pronađu Dobijte ponudu odmah
Još uvijek niste pronašli odgovarajućeg dobavljača Pustite verificirane dobavljače da vas pronađu
Dobijte ponudu odmah
Pošalji upit
+86
Kliknite za učitavanje datoteke

IEE Business will not sell or share your personal information.

Preuzmi
Dohvati IEE Business aplikaciju
Koristite IEE-Business aplikaciju za pronalaženje opreme, dobivanje rješenja, povezivanje s stručnjacima i sudjelovanje u suradnji u industriji u bilo koje vrijeme i na bilo kojem mjestu što potpuno podržava razvoj vaših projekata i poslovanja u energetici