• Ladle refining furnace transformer(distribution transformer)
Ladle refining furnace transformer(distribution transformer)
discuss personally
Model
SLR11-20000
Basic info
Brand Vziman
Model NO. Ladle refining furnace transformer
Rated capacity 20000kVA
Series Ladle refining furnace transformer
Product Detail

Description
The ladle refining furnace (LF furnace) transformer is a core equipment in the iron and steel smelting industry, primarily used to provide stable electric energy for the molten steel refining process. Its performance directly impacts the efficiency, energy consumption, and safety of steel production. With the development of electric furnace steelmaking technology, especially the popularization of large-scale LF furnaces above 40 tons, the design and technical standards of transformers have gradually shifted towards high efficiency and internationalization, forming a technological trend centered on energy conservation, reliability, and low maintenance.

Key Features

Energy Efficiency: Low no-load/load losses, optimized impedance voltage; uses Baowu/Nippon Steel 30Z130/30Q130 silicon steel. 

Reliability: 30+ year design life; fully oblique core joints, German Georg shear (<0.02mm burr), low-magnetic steel clamping. 

Overload Capability: Stable operation at 120% load via oxygen-free copper windings, small oil gaps, and cooling cylinder structures. Low Maintenance: 10+ years maintenance-free; vacuum oil injection, anti-aging seals, and folded plate tanks prevent leaks.

Components

Core

  • Material: Uses Baowu 30Z130 or Nippon Steel 30Q130 silicon steel, matching materials used in developed countries.

  • Structure: Full oblique-joint lamination design with low-magnetic steel plate pull rods for clamping, eliminating punching holes to ensure uniform magnetic flux density across core sections without distortion.

  • Processing: German Georg shearing line controls burrs ≤0.02mm (standard ≤0.05mm) and length tolerance ≤0.2mm/m, improving lamination factor to reduce local overheating, noise, and no-load losses.

Windings

  • Material: Oxygen-free copper magnet wires (P<0.017241 at 20°C) with precise insulation paper wrapping.

  • Design: Small oil gaps, internal/external oil baffles, and cooling cylinder structure enhance axial/radial stability, overload capacity, and reduce losses.

  • High-Voltage Solutions: "8"-type coils for one-time winding in high-load voltage regulation and 110kV-grade products, improving strength and reducing eddy current losses.

Body

  • Structure: Laminated wood for all wooden parts to enhance lead frame rigidity; upper/lower pressboards made of insulation boards or epoxy molded parts to increase conductor-to-ground insulation distance and reduce "window height" dimensions.

  • Insulation: Imported cardboard for main insulation, multi-coil integral assembly, and Norwegian steam drying equipment to ensure thorough drying without damaging insulation.

Oil Tank

  • Design: Folded plate structure minimizes welds, tested for positive/negative pressure to ensure sealing reliability.

  • Loss Reduction: Low-magnetic steel or magnetic shielding in strategic positions reduces additional losses from busbar magnetic fields on the tank wall, effectively preventing leakage and reducing losses.

Assembly

  • Process: Hydraulic compaction after body drying and vacuum oil injection to eliminate winding bubbles and reduce partial discharge.

  • Sealing: Anti-aging sealing materials address oil leakage; control circuits (gas relay, thermometers, etc.) integrated into a top-mounted junction box for a sleek, unified appearance.

Accessories

  • Cooling: YS1 water-coolers or stainless steel spiral plate coolers; anti-pollution high-voltage bushings increase creepage distance.

  • Tap Changers: Advanced "M" or "V" type from leading manufacturers with remote display and control interfaces.

  • Oil System: Karamay naphthenic anti-aging transformer oil in fully enclosed tanks with pressure relief valves and diaphragm conservators for complete protection.

Transformer Maintenance and Technical Assurance Summary

For transformer maintenance, long-distance transported core-hanging products require post-arrival checks to address loose fasteners and facilitate user acceptance, while routine overhauls should focus on replacing mechanical wear parts (e.g., pumps) per the original cycle. Quality assurance includes designing windings with a 20% overload margin (e.g., 24000kVA for a 20000kVA-rated LF furnace transformer) to ensure stable operation at 120% load, with impedance voltage ≤8% and heat load calculations based on the higher capacity. Anti-impact and short-circuit measures enhance coil axial/radial stability via high-voltage-grade wires, precise drying, hydraulic compaction, and multi-support structures. To guarantee 20-year maintenance-free operation, the design uses Karamay naphthenic oil in fully enclosed tanks with diaphragm conservators, anti-aging seals, and regular oil chromatographic analysis. Key improvements include Baowu/Nippon Steel silicon steel cores with ultra-low burr shearing, oxygen-free copper windings with small oil gaps, laminated wood bodies, folded-plate tanks with magnetic shielding, and integrated control systems. Future trends for ore-heating furnaces include single-phase transformers with side-mounted water-cooling for ≥15000kVA models, while maintenance prioritizes non-intrusive monitoring via oil analysis to reduce costs and contamination risks.

Know your supplier
Vziman
Zhejiang Vziman Electric Group Co., Ltd. is a high-tech enterprise specializing in R&D, manufacturing, and service of power electrical equipment. Committed to innovation, quality, and customer satisfaction, it supplies smart solutions for global power sectors, covering grid construction, new energy, and industrial distribution. Core Business • Switchgear (GIS, circuit breakers, Recloser, Load break switch) • Distribution equipment (transformers, RMU, smart terminals) • Power automation systems • Engineering services (installation, maintenance, consulting) Technical Strength • Provincial R&D center, multiple patents • Modern production, ISO/GB/IEC/CE/UL certified • High capacity, large-scale delivery support Market & Vision Serves State Grid, Southern Grid, and global projects (Asia, Africa, Europe, etc.). Aims to lead in smart grids and new energy, promoting sustainable energy development.
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150000000
Professional Experience
3 years
Workplace
10000m²
占位
占位
Related Products
Related Knowledges
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
The safe and economical operation of power transformers is related to the safety, economy, stability, and reliability of the operations of various industries. The limitations of conditions such as the investment economic indicators for its selection, the economic benefits of maintenance and operation, and the adaptability in the new environment (access of distributed power sources, configuration of energy storage, etc.) make it impossible to include comprehensive factors in other aspects.The cap
Leon
07/17/2025
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
1 IntroductionLow - voltage current transformers for metering, with a through - core type epoxy resin structure, are widely used in distribution transformer areas and for small - to - medium - sized industrial and commercial electricity consumption. As a range expander for electric energy metering, their performance directly relates to electricity consumption safety and the accuracy of users' trade calculations. Studying long - term immersion's impact on these transformers is practically signifi
Felix Spark
07/17/2025
What is reactive power measurement?
What is reactive power measurement?
The power which exists in the circuit when the voltage and current are out of phase to each other, such type of power is known as the reactive power. The formula measures the reactive power in the circuitReactive Power Measurement & VarmetersReactive power measurement is critical as it indicates circuit power loss: low reactive power worsens load power factor, increasing system losses. Varmeters (volt-ampere reactive meters) measure reactive power and are categorized by circuit phases:Single
Edwiin
07/17/2025
How to Design and Install a Solar PV System?
How to Design and Install a Solar PV System?
Design and Installation of Solar PV SystemsModern society relies on energy for daily needs like industry, heating, transport, and agriculture, mostly met by non-renewable sources (coal, oil, gas). However, these cause environmental harm, are unevenly distributed, and face price volatility due to limited reserves—driving demand for renewable energy.Solar energy, abundant and capable of meeting global needs, stands out. Standalone PV systems (Fig 1) offer energy independence from utilities.
Edwiin
07/17/2025
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
Low-voltage current transformers, as indispensable measurement and protection devices in power systems, often encounter various faults when used in combination with other power equipment due to environmental factors, equipment linkage issues, and improper installation and maintenance. These faults not only affect the normal operation of power equipment but may also endanger personal safety. Therefore, it is necessary to gain an in-depth understanding of fault types, judgment methods, and prevent
Felix Spark
07/17/2025
What are the monitoring methods and future development trends of low-voltage voltage transformers?
What are the monitoring methods and future development trends of low-voltage voltage transformers?
With the continuous advancement of smart grid technology, intelligent monitoring systems are playing an increasingly important role in preventing and addressing faults in voltage transformers. These modern intelligent monitoring systems can collect key parameters from voltage transformers in real time—such as partial discharge levels, temperature, and oil quality—and use data analysis algorithms to assess the health status of the equipment, enabling early fault warnings and precise l
Echo
07/16/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!