• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


110kV and 50kV AC SF6 Gas Insulated Voltage Transformer

  • 110kV and 50kV AC SF6 Gas Insulated Voltage Transformer
  • 110kV and 50kV AC SF6 Gas Insulated Voltage Transformer
  • 110kV and 50kV AC SF6 Gas Insulated Voltage Transformer

Key attributes

Brand Wone
Model NO. JDQXF-110 SF6 Gas Insulated Voltage Transformer
Primary voltage 110√3KV
Nominal voltage 110KV
insulation level 126/200/480KV
Series JDQXF-110

Product descriptions from the supplier

Description

Description:

An instrument used to convert voltage. However, the purpose of the transformer to convert the voltage is to facilitate the transmission of electric energy, so the capacity is very large, and it is generally calculated in kilovolt-ampere or megavolt-ampere; The purpose of the voltage transformer is to convert the voltage, which is mainly used to supply power to the measuring instrument and relay protection device, and is used to measure the voltage, power and electric energy of the line.

Industry applications:

It is suitable for outdoor and neutral point effective grounding in 110kV and 50kV AC power systems, for electric energy, voltage measurement and relay protection.

Features:

  •  This product is a single-phase, independent SF6 gas-insulated voltage transformer, which adopts a vertical structure, which is composed of several parts, such as a body, a metal shell, a lead pipe and a porcelain sleeve.

  • The transformer windings are single-stage structured, and the composite insulation composed of SF6 gas and rhombic dispensing polyester film can withstand high voltages. The low-voltage winding and high-voltage winding are equipped with internal and external electrostatic screens, and the high-voltage winding is also equipped with a shielding cover to further improve the field strength distribution. The high and low voltage windings are installed on the mouth core in a rectangular shape, and the whole body is fixed in the shell, and the shell is connected to the casing.

  •  The product is equipped with a primary connection plate, a grounding seat, a secondary junction box, an inflatable joint, a pressure gauge (density controller), an adsorbent and an anti-riot sheet.

  •  All sealing parts are sealed with O-shaped sealant gasket and coated with waterproof glue on the outside; The whole product is in a fully sealed state, and the product is filled with gas with rated pressure to ensure the normal operation of the product.

Technical parameters:

image.png


Dimension:

image.png


Product show:

091029818218004659.jpg


Why choose us:

  • We have a professional service team.

  • We have good after-sales.

  • We can guarantee the quality of our products.



Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 65666m²m² Total staff: 300+ Highest Annual Export(usD): 50000000
Workplace: 65666m²m²
Total staff: 300+
Highest Annual Export(usD): 50000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: Wire cable/High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/New energy/Tester/Integrated Electrical Equipment/Production equipment/Generator/Electrical fittings
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding Electrodes
    Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding ElectrodesWhen the grounding electrode of an Ultra-High-Voltage Direct Current (UHVDC) transmission system is located close to a renewable energy power station, the return current flowing through the earth can cause a rise in ground potential around the electrode area. This ground potential rise leads to a shift in the neutral-point potential of nearby power transformers, inducing DC bias (or DC offset) in their
    01/15/2026
  • HECI GCB for Generators – Fast SF6 Circuit Breaker
    1.Definition and Function1.1 Role of the Generator Circuit BreakerThe Generator Circuit Breaker (GCB) is a controllable disconnect point located between the generator and the step-up transformer, serving as an interface between the generator and the power grid. Its primary functions include isolating generator-side faults and enabling operational control during generator synchronization and grid connection. The operating principle of a GCB is not significantly different from that of a standard c
    01/06/2026
  • Distribution Equipment Transformer Testing, Inspection, and Maintenance
    1.Transformer Maintenance and Inspection Open the low-voltage (LV) circuit breaker of the transformer under maintenance, remove the control power fuse, and hang a “Do Not Close” warning sign on the switch handle. Open the high-voltage (HV) circuit breaker of the transformer under maintenance, close the grounding switch, fully discharge the transformer, lock the HV switchgear, and hang a “Do Not Close” warning sign on the switch handle. For dry-type transformer maintenance: first clean the porcel
    12/25/2025
  • How to Test Insulation Resistance of Distribution Transformers
    In practical work, insulation resistance of distribution transformers is generally measured twice: the insulation resistance between thehigh-voltage (HV) windingand thelow-voltage (LV) winding plus the transformer tank, and the insulation resistance between theLV windingand theHV winding plus the transformer tank.If both measurements yield acceptable values, it indicates that the insulation among the HV winding, LV winding, and transformer tank is qualified. If either measurement fails, pairwise
    12/25/2025
  • Design Principles for Pole-Mounted Distribution Transformers
    Design Principles for Pole-Mounted Distribution Transformers(1) Location and Layout PrinciplesPole-mounted transformer platforms should be located near the load center or close to critical loads, following the principle of “small capacity, multiple locations” to facilitate equipment replacement and maintenance. For residential power supply, three-phase transformers may be installed nearby based on current demand and future growth projections.(2) Capacity Selection for Three-Phase Pole-Mounted Tr
    12/25/2025
  • Transformer Noise Control Solutions for Different Installations
    1.Noise Mitigation for Ground-Level Independent Transformer RoomsMitigation Strategy:First, conduct a power-off inspection and maintenance of the transformer, including replacing aged insulating oil, checking and tightening all fasteners, and cleaning dust from the unit.Second, reinforce the transformer foundation or install vibration isolation devices—such as rubber pads or spring isolators—selected based on the severity of vibration.Finally, strengthen sound insulation at weak points of the ro
    12/25/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file

IEE Business will not sell or share your personal information.

Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.